Adenosine 5′-triphosphate (ATP) plays a crucial role as an extracellular signaling molecule in the central nervous system and is closely related to various nerve diseases. Therefore, label-free imaging of extracellular ATP dynamics and spatiotemporal analysis is crucial for understanding brain function. To decrease the limit of detection (LOD) of imaging extracellular ATP, we fabricated a redox-type label-free ATP image sensor by immobilizing glycerol-kinase (GK), L-α-glycerophosphate oxidase (LGOx), and horseradish peroxidase (HRP) enzymes in a polymer film on a gold electrode-modified potentiometric sensor array with a 37.3 µm-pitch. Hydrogen peroxide (H2O2) is generated through the enzymatic reactions from GK to LGOx in the presence of ATP and glycerol, and ATP can be detected as changes in its concentration using an electron mediator. Using this approach, the LOD for ATP was 2.8 µM with a sensitivity of 77 ± 3.8 mV/dec., under 10 mM working buffers at physiological pH, such as in in vitro experiments, and the LOD was great superior 100 times than that of the hydrogen ion detection-based image sensor. This redox-type ATP image sensor may be successfully applied for in vitro sensitive imaging of extracellular ATP dynamics in brain nerve tissue or cells.
Multi-analyte detection and imaging of extracellular chemical signaling molecules are crucial for understanding brain function and molecular pathology. In this work, we present a 6-μm-pitch, CMOS-based multichemical image sensor that enables the simultaneous visualization and spatiotemporal multimodal analysis of the lactate and proton (H+) dynamics without any labeling. Using semiconductor lithography, gold electrode patterns functioning as lactate-sensing regions were formed on a potentiometric sensor array. Lactate is detected potentiometrically because of redox reactions using lactate oxidase and horseradish peroxidase. The resulting multichemical image sensor exhibited a pH sensitivity of 65 mV and a superior detection limit of 1 μM for lactate with a reasonable selectivity. Furthermore, diffusion images of lactate and H+ distributions were obtained concurrently, allowing for simultaneous real-time imaging of the two chemicals with subcellular resolution. We believe that our novel imaging device can be successfully applied to extracellular microenvironments in tissue or cell samples as an effective bioimaging tool.
Towards clarifying the spatio-temporal neurotransmitter distribution, potentiometric redox sensor arrays with 23.5-µm resolution were fabricated. The sensor array based on a charge-transfer-type potentiometric sensor comprises pixels with gold electrodes deposited on the surface of pixels. The sensor output corresponding to the interfacial potential of the electrode changed logarithmically with the mixture ratio of KFe(CN) and KFe(CN), where the redox sensitivity reached 49.9 mV/dec. By employing hydrogen peroxidase as an enzyme and ferrocene as an electron mediator, the sensing characteristics for hydrogen peroxide (HO) were investigated. The analyses of the sensing characteristics revealed that the sensitivity was about 44.7 mV/dec., comparable to the redox sensitivity, while the limit of detection (LOD) was achieved to be 1 µM. Furthermore, the oxidation state of the electron mediator can be the key to further lowering the LOD. Then, by immobilizing oxidizing enzyme for HO and glutamate oxidase, glutamate (Glu) measurements were conducted. As a result, similar sensitivity and LOD to those of HO were obtained. Finally, the real-time distribution of 1 µM Glu was visualized, demonstrating the feasibility of our device as a high-resolution bioimaging technique.
An elevation of intracellular Ca 2+ concentration during neuronal excitation is widely known, and much research has already been done. However, the changes in "extracellular" Ca 2+ concentration ([Ca 2+ ]o) have received only limited attention, and its imaging and spatiotemporal analysis has not been achieved. Thus, we develop a [Ca 2+ ]o imaging sensor to clarify the role(s) of [Ca 2+ ]o in regulation of physiological and pathophysiological neurons. 23.55-µm-pitch and 128×128 pixels Ca 2+ image sensor using plasticized polyvinyl chloride (PVC) as an ion sensitive membrane was fabricated and the diffusion image of Ca 2+ concentration in sample solution was successfully obtained. The sensitivity was 23.3 mV/decade. The mouse hippocampal slice was placed on the sensor, and stimulated with glutamate and its related agonists. When stimulated, the output image was clearly changed, i.e., glutamate decreased [Ca 2+ ]o via NMDA receptor. We also found that such [Ca 2+ ]o changes were obvious in CA3 and dentate gyrus (DG) of the hippocampus, and were not observed in the slice-free sensor area. Taken together, we succeeded in the development of the [Ca 2+ ]o imaging device, allowing us to monitor and analyze real-time imaging of the spatiotemporal changes in [Ca 2+ ]o in the brain slices.
Because extracellular potassium ion $([\mathbf{K}^{+}]_{\mathbf{o}})$ plays an important role in the regulation of the physiological and pathophysiological activity of neurons, the imaging of $[\mathbf{K}^{+}]_{\mathbf{O}}$ dynamics and its spatiotemporal analysis is crucial for understanding brain function. Toward the high spatiotemporal imaging of $[\mathbf{K}^{+}]_{\mathbf{o}}$ dynamics in the brain, we fabricated a $23.55-\mu \mathrm{m}$ -pitch and $128\times 128$ -pixel label-free $\mathbf{K}^{+}$ image sensor, in which different thicknesses were deposited by controlling the volume of the polyvinyl chloride (PVC) membrane solution, and the detection performance was investigated. In the investigation of the characteristics of K + measurement with sensors of different thicknesses, the sensors whose film thickness was decreased 9 $\mu\mathrm{m}$ exhibited superior K + sensitivity with reasonable selectivity. When acutely sliced mouse hippocampus was stimulated with glutamate on the K + ionophore-immobilized sensor, the output signal was increased in the hippocampal CAl, CA3, and DG regions, but no signal was observed when the slice was stimulated on a sensor without K + ionophore. Additionally, the spatiotemporal resolution of output images obtained from the $9-\mu \mathrm{m}$ thick sensor was higher than those from the $108-\mu \mathrm{m}$ thick sensor. Taken together, we succeeded in the real-time imaging of $[\mathbf{K}^{+}]_{\mathbf{o}}$ from the acute mouse hippocampal slices, and demonstrated for the first time that membrane thickness significantly affects the spatial resolution of $[\mathbf{K}^{+}]_{\mathbf{o}}$ dynamics.