Yong-Joon Choi

Dr. Yong-Joon Choi

Toyohashi University of Technology, Toyohashi, Aichi, Japan
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
KTKazuhiro Takahashi
Kazuhiro Takahashi
NMNobuo Misawa
Nobuo Misawa
THTakeshi Hizawa
Takeshi Hizawa
TITatsuya Iwata
Tatsuya Iwata
KSKazuaki Sawada
Kazuaki Sawada

23 March 2016 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
KTKazuhiro Takahashi
Kazuhiro Takahashi
MMMotoharu Matsuda
Motoharu Matsuda
THTakeshi Hizawa
Takeshi Hizawa
YMYu Moriwaki
Yu Moriwaki
KSKazuaki Sawada
Kazuaki Sawada
The improvement of a filter-less fluorescence sensor, by suppressing forward scattering in silicon by surface planarization is presented. A fluorescence microscope has been widely used in biochemical fields. However, it is difficult to miniaturize because optical filters and other parts are necessary. We previously developed a filter-less fluorescence sensor. The separation ability of excitation light and fluorescence in the previous device was 550:1. It is necessary to improve the separation ability. This study focuses on the suppression of forward-scattered incident light in silicon, through the enhanced surface planarization of polysilicon, which is the gate electrode material. The separation ability of the filter-less fluorescence sensor was increased from 550:1 to 1250:1 by the suppression of forward-scattered light.

1 January 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
TTToshiaki Takahashi
Toshiaki Takahashi
MTMiki Taki
Miki Taki
KSKazuaki Sawada
Kazuaki Sawada
KTKazuhiro Takahashi
Kazuhiro Takahashi

10 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TMTomoya Maeda
Tomoya Maeda
RKRyoto Kanamori
Ryoto Kanamori
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
MTMiki Taki
Miki Taki
TNToshihiko Noda
Toshihiko Noda
KTKazuhiro Takahashi
Kazuhiro Takahashi
Various biosensors that are based on microfabrication technology have been developed as point-of-care testing devices for disease screening. The Fabry–Pérot interferometric (FPI) surface-stress sensor was developed to improve detection sensitivity by performing label-free biomarker detection as a nanomechanical deflection of a freestanding membrane to adsorb the molecules. However, chemically functionalizing the freestanding nanosheet with excellent stress sensitivity for selective molecular detection may cause the surface chemical reaction to deteriorate the nanosheet quality. In this study, we developed a minimally invasive chemical functionalization technique to create a biosolid interface on the freestanding nanosheet of a microelectromechanical system optical interferometric surface-stress immunosensor. For receptor immobilization, glutaraldehyde cross-linking on the surface of the amino-functionalized parylene membrane reduced the shape variation of the freestanding nanosheet to 1/5–1/10 of the previous study and achieved a yield of 95%. In addition, the FPI surface-stress sensor demonstrated molecular selectivity and concentration dependence for prostate-specific antigen with a dynamic range of concentrations from 100 ag/mL to 1 µg/mL. In addition, the minimum limit of detection of the proposed sensor was 2,000,000 times lower than that of the conventional nanomechanical cantilevers.

17 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
KNKakeru Nakano
Kakeru Nakano
TITomoya Ide
Tomoya Ide
TSTsugumi Sakae
Tsugumi Sakae
RIRyosuke Ichikawa
Ryosuke Ichikawa
KSKazuaki Sawada
Kazuaki Sawada
This study proposed a filter-free wavelength sensor with a double-well structure for detecting fluorescence without an optical filter. The impurity concentration was optimized and simulated to form a double-well-structured sensor, of which the result was consistent with the fabricated sensor. Furthermore, we proposed a novel wavelength detection method using the current ratio based on the silicon absorption coefficient. The results showed that the proposed method successfully detected single wavelengths in the 460–800 nm range. Additionally, we confirmed that quantification was possible using the current ratio of the sensor for a relatively wide band wavelength, such as fluorescence. Finally, the fluorescence that was emitted from the reagents ALEXA488, 594, and 680 was successfully identified and quantified. The proposed sensor can detect wavelengths without optical filters, which can be used in various applications in the biofield, such as POCT as a miniaturized wavelength detection sensor.

23 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HDHideo Doi
Hideo Doi
THTomoko Horio
Tomoko Horio
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
KTKazuhiro Takahashi
Kazuhiro Takahashi
TNToshihiko Noda
Toshihiko Noda
KSKazuaki Sawada
Kazuaki Sawada
Adenosine 5′-triphosphate (ATP) plays a crucial role as an extracellular signaling molecule in the central nervous system and is closely related to various nerve diseases. Therefore, label-free imaging of extracellular ATP dynamics and spatiotemporal analysis is crucial for understanding brain function. To decrease the limit of detection (LOD) of imaging extracellular ATP, we fabricated a redox-type label-free ATP image sensor by immobilizing glycerol-kinase (GK), L-α-glycerophosphate oxidase (LGOx), and horseradish peroxidase (HRP) enzymes in a polymer film on a gold electrode-modified potentiometric sensor array with a 37.3 µm-pitch. Hydrogen peroxide (H2O2) is generated through the enzymatic reactions from GK to LGOx in the presence of ATP and glycerol, and ATP can be detected as changes in its concentration using an electron mediator. Using this approach, the LOD for ATP was 2.8 µM with a sensitivity of 77 ± 3.8 mV/dec., under 10 mM working buffers at physiological pH, such as in in vitro experiments, and the LOD was great superior 100 times than that of the hydrogen ion detection-based image sensor. This redox-type ATP image sensor may be successfully applied for in vitro sensitive imaging of extracellular ATP dynamics in brain nerve tissue or cells.