Kazuaki Sawada

Prof. Dr. Kazuaki Sawada

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2006 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
YKYoshiko Kato
Yoshiko Kato
HTHidekuni Takao
Hidekuni Takao
KSKazuaki Sawada
Kazuaki Sawada
MIMakoto Ishida
Makoto Ishida

1 March 2018 in Talanta
Verified
Journal Article
Closed access
YLYou-Na Lee
You-Na Lee
KOKoichi Okumura
Koichi Okumura
THTomoko Horio
Tomoko Horio
TITatsuya Iwata
Tatsuya Iwata
KTKazuhiro Takahashi
Kazuhiro Takahashi
KSKazuaki Sawada
Kazuaki Sawada

12 July 2010 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
HTHidekuni Takao
Hidekuni Takao
TITakehiko Ichikawa
Takehiko Ichikawa
TNTooru Nakata
Tooru Nakata
KSKazuaki Sawada
Kazuaki Sawada
MIMakoto Ishida
Makoto Ishida
In this paper, a versatile integration technology for thick-film silicon-on-insulator microelectromechanical systems (SOI-MEMS) devices with CMOS electronics using novel microbridge interconnections is reported. The microbridge interconnection proposed in this paper solves the problem regarding the electrical isolation and interconnection between CMOS and SOI-MEMS devices. The integration of SOI-MEMS requires only three additional photolithography steps for the CMOS wafers fabricated by a standard process. On the basis of the developed technology, SOI-MEMS devices integrated with CMOS circuits were fabricated using 20-μm-thick SOI wafers. No significant damage was observed in the measured characteristics of the fabricated CMOS after the integration of MEMS devices. In addition, the electrical isolation of SOI-MEMS from the CMOS substrate was successfully realized and confirmed in the experiment, keeping electrical connectivity between CMOS circuit terminals. The measured isolation resistance between MEMS and the CMOS substrate was more than 1012 Ω, and a proof voltage above 60 Vdc was observed. These values guarantee a small leakage current and a sufficient voltage swing for driving electrostatic microactuators. On the other hand, the resistance of the interconnection over a microbridge structure was below 1 Ω, which is sufficiently low for integrating low-noise microsensors. This integration technology can be used in realizing monolithically integrated SOI-MEMS sensor and actuator devices with high-aspect-ratio structures using the most cost-effective and versatile CMOS fabrication technologies.

1 May 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
HDHideo Doi
Hideo Doi
BPBijay Parajuli
Bijay Parajuli
THTomoko Horio
Tomoko Horio
ESEiji Shigetomi
Eiji Shigetomi
YSYouichi Shinozaki
Youichi Shinozaki
KSKazuaki Sawada
Kazuaki Sawada

10 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TMTomoya Maeda
Tomoya Maeda
RKRyoto Kanamori
Ryoto Kanamori
Yong-Joon ChoiYong-Joon Choi
Yong-Joon Choi
MTMiki Taki
Miki Taki
TNToshihiko Noda
Toshihiko Noda
KTKazuhiro Takahashi
Kazuhiro Takahashi
Various biosensors that are based on microfabrication technology have been developed as point-of-care testing devices for disease screening. The Fabry–Pérot interferometric (FPI) surface-stress sensor was developed to improve detection sensitivity by performing label-free biomarker detection as a nanomechanical deflection of a freestanding membrane to adsorb the molecules. However, chemically functionalizing the freestanding nanosheet with excellent stress sensitivity for selective molecular detection may cause the surface chemical reaction to deteriorate the nanosheet quality. In this study, we developed a minimally invasive chemical functionalization technique to create a biosolid interface on the freestanding nanosheet of a microelectromechanical system optical interferometric surface-stress immunosensor. For receptor immobilization, glutaraldehyde cross-linking on the surface of the amino-functionalized parylene membrane reduced the shape variation of the freestanding nanosheet to 1/5–1/10 of the previous study and achieved a yield of 95%. In addition, the FPI surface-stress sensor demonstrated molecular selectivity and concentration dependence for prostate-specific antigen with a dynamic range of concentrations from 100 ag/mL to 1 µg/mL. In addition, the minimum limit of detection of the proposed sensor was 2,000,000 times lower than that of the conventional nanomechanical cantilevers.

1 April 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
YMYuji Murakami
Yuji Murakami
KAK. Araki
K. Araki
ROR. Ohashi
R. Ohashi
HHH. Honma
H. Honma
NMNobuo Misawa
Nobuo Misawa
MIMasatoshi Ishida
Masatoshi Ishida