José María P. Sala Lizarraga

Dr. José María P. Sala Lizarraga

Research Group Energy in Buildings (ENEDI), Department of Thermal Engineering, University of the Basque Country (UPV/EHU), 48013 Bilbao, Spain

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Energy
Verified
Journal Article
Closed access
EIE. Iturriaga
E. Iturriaga
UAU. Aldasoro
U. Aldasoro
ACAlvaro Campos-Celador
Alvaro Campos-Celador
JLJosé María P. Sala Lizarraga
José María P. Sala Lizarraga

30 March 2016 in Energies
Verified
Journal Article
Open access
PDF file
ELEdorta Carrascal Lekunberri
Edorta Carrascal Lekunberri
Izaskun GarridoIzaskun Garrido
Izaskun Garrido
Aitor GarridoAitor Garrido
Aitor Garrido
JLJosé María P. Sala Lizarraga
José María P. Sala Lizarraga
This work presents the implementation of a Model Predictive Control (MPC) scheme used to study the improvement of the thermal quality in aged residential buildings without any rehabilitation. The controller manages the heating system of an experimentally characterized model of a residential dwelling in a social block built during the decade of the 1960s located in the neighborhood of Otxarkoaga (Bilbao, Spain), so as to obtain an optimal energy efficiency performance. Due to the characteristics of the construction in those days, this kind of buildings suffer problems related to the use of awkward building materials and inefficient heating systems. A comparison with traditionally used ON-OFF hysteresis control is presented in order to demonstrate the energetic improvement provided by the MPC scheme. Besides, the variation of different parameters of the MPC is also studied to determine its influence over the energy consumption and comfort conditions.

25 December 2019 in Entropy
Verified
Journal Article
Open access
PDF file
Ana Picallo-PerezAna Picallo-Perez
Ana Picallo-Perez
JLJosé María P. Sala Lizarraga
José María P. Sala Lizarraga
George TsatsaronisGeorge Tsatsaronis
George Tsatsaronis
SSSaeed Sayadi
Saeed Sayadi
This work applies the Dynamic Advanced Exergy Analysis (DAEA) to a heating and domestic hot water (DHW) facility supplied by a Stirling engine and a condensing boiler. For the first time, an advanced exergy analysis using dynamic conditions is applied to a building energy system. DAEA provides insights on the components’ exergy destruction (ED) by distinguishing the inefficiencies that can be prevented by improving the quality (avoidable ED) and the ones constrained because of technical limitations (unavoidable ED). ED is related to the inherent inefficiencies of the considered element (endogenous ED) and those coming from the interconnections (exogenous ED). That information cannot be obtained by any other approach. A dynamic calculation within the experimental facility has been performed after a component characterization driven by a new grey-box modelling technique, through TRNSYS and MATLAB. Novel solutions and terms of ED are assessed for the rational implementation of the DAEA in building energy installations. The influence of each component and their interconnections are valuated in terms of exergy destruction for further diagnosis and optimization purposes.

10 February 2017 in Energies
Verified
Journal Article
Open access
PDF file
ELEdorta Carrascal Lekunberri
Edorta Carrascal Lekunberri
Izaskun GarridoIzaskun Garrido
Izaskun Garrido
BHBram Van der Heijde
Bram Van der Heijde
Aitor GarridoAitor Garrido
Aitor Garrido
JLJosé María P. Sala Lizarraga
José María P. Sala Lizarraga
LHLieve Helsen
Lieve Helsen
The two spaces office module is usually considered as a representative case-study to analyse the energetic improvement in office buildings. In this kind of buildings, the use of a model predictive control (MPC) scheme for the climate system control provides energy savings over 15% in comparison to classic control policies. This paper focuses on the influence of solar radiation on the climate control of the office module under Belgian weather conditions. Considering MPC as main climate control, it proposes a novel distributed enhanced control for the blind system (BS) that takes into account part of the predictive information of the MPC. In addition to the savings that are usually achieved by MPC, it adds a potential 15% improvement in global energy use with respect to the usually proposed BS hysteresis control. Moreover, from the simulation results it can be concluded that the thermal comfort is also improved. The proposed BS scheme increases the energy use ratio between the thermally activated building system (TABS) and air-handling unit (AHU); therefore increasing the use of TABS and allowing economic savings, due to the use of more cost-effective thermal equipment.

24 July 2024 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Open access
Javier M. Rey HernándezJavier M. Rey Hernández
Javier M. Rey Hernández
FMFrancisco J. Rey Martínez
Francisco J. Rey Martínez
JLJosé María P. Sala Lizarraga
José María P. Sala Lizarraga
Ana Picallo-PerezAna Picallo-Perez
Ana Picallo-Perez
This study evaluates the energy and exergy performance of buildings towards achieving nearly Zero Energy Building (nZEB) standards by introducing three exergy-based indicators alongside conventional energy metrics. Focused on the LEED Platinum-certified LUCIA building at Valladolid University (Spain), the analysis examines energy and exergy transformations throughout the building’s lifecycle, emphasizing resource consumption, generation systems, and environmental equilibrium across seasons. The study reveals a Non-Renewable Primary Energy Ratio of 67 kWh/m2, closely mirrored by an exergy ratio of 67.2 kWh/m2 due to the high-quality factor of fuel resources. Conversely, the Renewable Primary Energy Ratio stands at 121 kWh/m2, with a corresponding exergy ratio of 88.36 kWh/m2, reflecting the significant contribution of geothermal energy while highlighting areas for demand side optimization. For the same reason, the Renewable Energy Ratio is 0.66 and the Exergy Ratio is 0.56. Despite meeting nZEB criteria, exergy indicators underscore untapped energy-saving potential by aligning resource qualities with demand characteristics. Identifying system weaknesses informs future improvement strategies, potentially enhancing LEED scores. The study advocates for incorporating exergy-based indicators alongside traditional energy metrics in European regulations to accurately assess building performance and define low-ex buildings. Overall, the exergy analysis reveals equipment-specific losses and underscores the qualitative match between energy demand and supply.

15 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ana Picallo-PerezAna Picallo-Perez
Ana Picallo-Perez
JLJosé María P. Sala Lizarraga
José María P. Sala Lizarraga
This work defines and analyzes the performance of a polygeneration system in five different locations in Spain to maintain the thermal comfort and air quality of an office building. The facility is based on a chiller and a CHP engine with PV panels that provide almost all the electricity demand of the chiller. According to the energy performance analysis results, the installation working in Bilbao is a full polygeneration system since no electricity needs to be imported from the grid in summer. To quantify the energy savings related to a separated production facility, polygeneration indicators (percentage of savings PES/PExS and equivalent electric efficiency EEE/EExE) have been calculated in energy and exergy terms. The main motivation for using exergy is based on the ambiguity that can arise from the point of view of the First Law. As expected, the exergetic indicators have lower values than the energetic ones. In addition, an in-depth analysis was conducted for the air-handling unit components. The study shows the behavior of components over the year and the efficiency values from both an energy and exergy point of view. From these facts, the need arises to develop methodologies based on exergy.