Anna Taratuta Taratuta

Mrs. Anna Taratuta Taratuta

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2022 in Coatings
Verified
Journal Article
Open access
PDF file
JLJulia Lisoń
Julia Lisoń
ATAnna Taratuta Taratuta
Anna Taratuta Taratuta
ZPZbigniew Paszenda
Zbigniew Paszenda
Magdalena Monika SzindlerMagdalena Monika Szindler
Magdalena Monika Szindler
MBMarcin Basiaga
Marcin Basiaga
The opportunity of decreasing the development of biofilm on the implant surface is one of the biggest research problems. It is connected with the existing prevention of microorganism hyperplasia. The application of numerous modifications is concerned with surface treatments leading to minimizing bacterial colonization. In the case of non-use antibacterial therapy, this leads to tissue infection. It can lead to a decreased opportunity to fight infection using antibiotherapy. One way is to decrease the increasing biofilm application which requires a method of modification. These techniques ensure properties like homogeneity or repeatability. The structure and chemical composition are changed with methods like CVD (Chemical Vapor Deposition), PVD (Physical Vapor Deposition), sol–gel, or ALD (Atomic Layer Deposition). Antibacterial properties of metals are connected with their impact on proteins and the nuclear proliferation of fibroblasts, causing improvement in biocompatibility and also growth corrosion resistance, and the decline of biofilm adhesion. The prevention of biofilm with medicines and antibiotics is a crowded-out treatment. Traditional methods of preventing biofilm are based on compounds that kill or inhibit the growth of the microbes but at the same time lead to frequent development of resistance to antibiotics. This review summarizes the current knowledge of reducing and preventing the creation of biofilm.

20 May 2023 in Vacuum
Verified
Journal Article
Open access
ATAnna Taratuta Taratuta
Anna Taratuta Taratuta
JLJulia Lisoń-Kubica
Julia Lisoń-Kubica
ZPZbigniew Paszenda
Zbigniew Paszenda
JSJanusz Szewczenko
Janusz Szewczenko
AKAlicja Kazek-Kęsik
Alicja Kazek-Kęsik
MBMarcin Basiaga
Marcin Basiaga

19 May 2025 in Langmuir
Verified
Journal Article
Open access
JLJulia Lisoń
Julia Lisoń
ATAnna Taratuta Taratuta
Anna Taratuta Taratuta
KWKarolina Wilk
Karolina Wilk
JKJulia Kolasa
Julia Kolasa
Magdalena Antonowicz-HüpschMagdalena Antonowicz-Hüpsch
Magdalena Antonowicz-Hüpsch
MBMarcin Basiaga
Marcin Basiaga
Biomaterials used for bone implants should be characterized by good corrosion resistance, appropriate mechanical and electrical properties, high metallurgical quality, biocompatibility, abrasion resistance, and relatively low production costs. Currently used titanium alloys are being replaced by materials with better biocompatibility, so-called new-generation titanium alloys containing elements such as vanadium or niobium. These alloys, with the addition of Zr, Fe, or Ta, give Young's modulus values approximating that of bone, thus further improving the biocompatibility of the biomaterial. The aim of this study was to assess the impact on its physicochemical and mechanical properties of modifying Ti-13Nb-13Zr alloy with a titanium nitride (TiN) layer using PVD. The knowledge obtained has practical significance for the use of this type of surface modification for various types of miniaturized implants used, for example, in the skeletal system. As part of the assessment of the physicochemical properties of the resulting surface layers, microscopic observations (SEM), potentiodynamic tests, impedance tests, surface wettability tests, scratch tests, and layer abrasion tests were performed. Based on the results obtained, various physicochemical properties of the modified alloy were recorded, depending on the surface modification process. As a result, better properties were noted with respect to corrosion resistance, especially for the tribological properties and the surface resistance to abrasion. The knowledge obtained from this research has practical significance for the use of this type of surface modification for various types of miniaturized implants used in the skeletal system.

27 June 2025 in Annals of the New York Academy of Sciences
Verified
Journal Article
Closed access
ATAnna Taratuta Taratuta
Anna Taratuta Taratuta
MAMagdalena Antonowicz
Magdalena Antonowicz
KGKarolina Goldsztajn
Karolina Goldsztajn
BRBarbara Rynkus
Barbara Rynkus
JLJulia Lisoń‐Kubica
Julia Lisoń‐Kubica
MBMarcin Basiaga
Marcin Basiaga

22 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
KWKarolina Wilk
Karolina Wilk
MKMaciej Krzywiecki
Maciej Krzywiecki
LGLucyna Grządziel
Lucyna Grządziel
Marcin GodzierzMarcin Godzierz
Marcin Godzierz
ATAnna Taratuta Taratuta
Anna Taratuta Taratuta
JSJanusz Szewczenko
Janusz Szewczenko
Titanium alloys belong to the metal biomaterials that are one of the most widely used in medicine. In recent years, in order to reduce the use of vanadium, Ti6Al4V alloy is increasingly replaced by Ti6Al7Nb alloy. In addition, to ensure the best possible biocompatibility, its surface is subjected to appropriate modifications, for example, anodic oxidation. Despite the extensive use of anodic oxidation of titanium implants in orthopedics, there are few works focused on a detailed analysis of the chemical composition of the surface layers. In addition, the effect of treatments before anodic oxidation on the properties of the produced layer has not been analyzed. Thus, the purpose of this study was to analyze in detail the chemical composition of the passive layer of Ti6Al7Nb alloy obtained by anodic oxidation preceded by sandblasting. Moreover, the physicochemical properties of the analyzed surface affecting biocompatibility were determined. For this purpose, surface observation, wettability and roughness tests, microhardness tests, electrochemical tests and phase composition analysis were carried out. In addition, the preclinical suitability, of the surface modified in this way, was evaluated by cytotoxicity tests.

30 June 2023 in Tribologia
Verified
Journal Article
Closed access
JLJulia Lisoń
Julia Lisoń
ATAnna Taratuta Taratuta
Anna Taratuta Taratuta
Magdalena Antonowicz-HüpschMagdalena Antonowicz-Hüpsch
Magdalena Antonowicz-Hüpsch
MBMarcin Basiaga
Marcin Basiaga
The research describes an atomic layer deposition (ALD) coating method and its application on a new generationof titanium alloy (Ti13Nb13Zr) for biomedical applications. The study aimed to assess the physicochemicalproperties and mechanics of a titanium alloy coated with titanium oxide (TiO2) or aluminium oxide (Al2O3)using the ALD method. The physicochemical properties of the surface coatings were evaluated throughmicroscopic observations, potentiodynamic tests, surface wettability tests, optical profilometry scratch tests,and abrasion tests. Based on the data obtained, different physicochemical properties of the alloy with titaniumnitride and titanium oxide coatings were found. Such differences were dependent on the number of cyclesused and the temperature of the manufacturing process. The coatings have reduced the abrasion coefficient,thus improving the abrasion resistance of the Ti13Nb13Zr alloy, which enables their use within the skeletalsystem. These findings are of practical importance for applying this type of surface modification to varioustypes of miniaturised implants used in the skeletal system.