Bandwidth is an important parameter for accelerometers, in some cases, even surpassing sensitivity. However, there are few studies focused on the relationship between bandwidth and environmental conditions in practical application of accelerometers. In this paper, we systematically analyze the influence of environment on the bandwidth of accelerometers, obtaining the amplitude–frequency response curves versus damping ratio and properties of materials, wherein temperature and humidity were found as the two dominant factors that influence the bandwidth of accelerometers. Common temperature and humidity variations can result in bandwidth degradation of about 25% according to our theoretical analysis. The finite element method (FEM) is introduced to verify our theoretical analysis, and the accordance of the FEM simulation results and the theoretical results confirmed the validity of our analysis. Furthermore, a modification design is proposed to compensate for the influence of temperature and humidity on the bandwidth of accelerometers. By choosing materials with an appropriate Young’s modulus and coefficient of thermal expansion, the degradation of the bandwidth was substantially diminished by more than one order of magnitude, which can serve as a strong guide for the future realization of accelerometers with a steady and large bandwidth.
The surge in fabrication techniques for micro- and nanodevices gave room to rapid growth in these technologies and a never-ending range of possible applications emerged. These new products significantly improve human life, however, the evolution in the design, simulation and optimization process of said products did not observe a similarly rapid growth. It became thus clear that the performance of micro- and nanodevices would benefit from significant improvements in this area. This work presents a novel methodology for electro-mechanical co-optimization of micro-electromechanical systems (MEMS) inertial sensors. The developed software tool comprises geometry design, finite element method (FEM) analysis, damping calculation, electronic domain simulation, and a genetic algorithm (GA) optimization process. It allows for a facilitated system-level MEMS design flow, in which electrical and mechanical domains communicate with each other to achieve an optimized system performance. To demonstrate the efficacy of the methodology, an open-loop capacitive MEMS accelerometer and an open-loop Coriolis vibratory MEMS gyroscope were simulated and optimized—these devices saw a sensitivity improvement of 193.77% and 420.9%, respectively, in comparison to their original state.
Owing to inevitable errors of the material and fabrication process, the cross-axis sensitivity commonly exists in a large number of MEMS devices based on parallel plate structures. Such cross-axis interference results in the non-negligible rotation of the plate that deteriorates the performance of MEMS devices. Therefore, suppressing the cross-axis sensitivity is extremely critical in the device design. This paper proposes a novel theory to identify the interplay between the cross-axis interference and squeeze film air damping, and further develops a correlated theory of the damping induced suppression. The model of tilting plate with a tiny amplitude is set up by exploiting the Reynolds equation coupled with the equations of the mass deflection, and the analytical expressions of corresponding properties are derived to elucidate the suppression mechanism and its characterization. The analytical calculation and numerical simulation analysis demonstrate that the damping induced improvement effect exists objectively and is remarkable in the condition of a large mass and a small air film thickness. The cross-axis sensitivity rendered by the tilt angle quantitatively declines 80% in terms of the air damping. The theoretical underpinning can be utilized to elaborate the ubiquitous interplay between squeeze film air damping and cross-axis interference in non-vacuum MEMS devices, which is of paramount importance for achieving high performance and stability. More importantly, it is not an exclusive method that can be combined with other methods to minimize the cross-axis interference fully.
This paper presents a platform for weakly coupled mechanical and electrical resonators with arbitrary tunability. Two- and three-degree-of-freedom (DoF) weakly coupled resonator systems are demonstrated experimentally with this platform, showing excellent tuning and matching flexibility. Fully electrical coupling logic circuitry gives the proposed system better adjustability and lower susceptibility to fabrication tolerances compared to purely mechanical weakly coupled resonators. Due to its mother/daughter board structure and the simplicity of the coupling logic, the proposed system can easily be extended to any-DoF systems.
This paper reports on a gas sensor based on two bulk acoustic wave (BAW) resonators electrically coupled with a tuneable capacitor. The weak coupling strength was tuned to its optimal value (achieving maximum sensitivity) by varying the capacitance (without complex filtering, a control circuit as required in the state of the art). A gas sensor was developed based on the electrically coupled BAW resonators by functionalizing one of the resonators with zeolitic imidazolate framework-8 (ZIF-8). It featured a quality (Q) factor of ~2.2 k in air and a resonance frequency of ~6.32 MHz. Such a simple coupling mechanism can be tuned and further extended to coupled resonators in other domains.
This work presents a simple method to extract the piezoelectric coefficient based on analytical model fitting. A theoretical circuit model is developed for a piezoelectric circular membrane actuator based on PZT thin film. The circular diaphragm consists of a 12 µm silicon layer, an 800 nm thick PZT layer, and a 200 nm Ti/Pt layer, featuring a single 50% inner top electrode coverage. The proposed model is validated by the finite element method with a 2D axisymmetric model of a PZT piezoelectric membrane. Further, piezoelectric coefficient is extracted by fitting the Laser Doppler Vibrometer (LDV) experimental result with the analytical model.