Danny Brouard

Dr. Danny Brouard


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in Journal of Trauma and Acute Care Surgery
Verified
Journal Article
Open access
VHValerie Homier
Valerie Homier
DBDanny Brouard
Danny Brouard
MNMichael Apc Nolan
Michael Apc Nolan
MRMarie-Andrée Roy
Marie-Andrée Roy
PPPatricia Pelletier
Patricia Pelletier
RFRichard Fleet
Richard Fleet
BACKGROUND: Timely and safe distribution of quality blood products is a major challenge faced by blood banks around the world. Our primary objective was to determine if simulated blood product delivery to an urban trauma center would be more rapidly achieved by unmanned aerial vehicle (UAV) than by ground transportation. A secondary objective was to determine the feasibility of maintaining simulated blood product temperatures within a targeted range. METHODS: In this prospective pilot study, we used two distinct methods to compare UAV flight duration and ground transport times. Simulated blood products included packed red blood cells, platelet concentrate, and fresh frozen plasma. For each blood product type, three UAV flights were conducted. Temperature was monitored during transport using a probe coupled to a data logger inside each simulated blood product unit. RESULTS: All flights were conducted successfully without any adverse events or safety concerns reported. The heaviest payload transported was 6.4 kg, and the drone speed throughout all nine flights was 10 m/s. The mean UAV transportation time was significantly faster than ground delivery (17:06 ± 00:04 minutes vs. 28:54 ± 01:12 minutes, p < 0.0001). The mean ± SD initial temperature for packed red blood cells was 4.4°C ± 0.1°C with a maximum 5% mean temperature variability from departure to landing. For platelet concentrates, the mean ± SD initial temperature was 21.6°C ± 0.5°C, and the maximum variability observed was 0.3%. The mean ± SD initial fresh frozen plasma temperature was −19°C ± 2°C, and the greatest temperature variability was from −17°C ± 2°C to −16°C ± 2°C. CONCLUSIONS: Unmanned aerial vehicle transportation of simulated blood products was significantly faster than ground delivery. Simulated blood product temperatures remained within their respective acceptable ranges throughout transport. Further studies assessing UAV transport of real blood products in populated areas are warranted. LEVEL OF EVIDENCE: Therapeutic/care management, level IV.

14 January 2022 in Antibiotics
Verified
Journal Article
Open access
PDF file
SFSahra Fonseca
Sahra Fonseca
MCMarie-Pierre Cayer
Marie-Pierre Cayer
KAK.M. Tanvir Ahmmed
K.M. Tanvir Ahmmed
NKNima Khadem-Mohtaram
Nima Khadem-Mohtaram
Steve CharetteSteve Charette
Steve Charette
DBDanny Brouard
Danny Brouard
Technological innovations and quality control processes within blood supply organizations have significantly improved blood safety for both donors and recipients. Nevertheless, the risk of transfusion-transmitted infection remains non-negligible. Applying a nanoparticular, antibacterial coating at the surface of medical devices is a promising strategy to prevent the spread of infections. In this study, we characterized the antibacterial activity of an SiO2 nanoparticular coating (i.e., the “Medical Antibacterial and Antiadhesive Coating” [MAAC]) applied on relevant polymeric materials (PM) used in the biomedical field. Electron microscopy revealed a smoother surface for the MAAC-treated PM compared to the reference, suggesting antiadhesive properties. The antibacterial activity was tested against selected Gram-positive and Gram-negative bacteria in accordance with ISO 22196. Bacterial growth was significantly reduced for the MAAC-treated PVC, plasticized PVC, polyurethane and silicone (90–99.999%) in which antibacterial activity of ≥1 log reduction was reached for all bacterial strains tested. Cytotoxicity was evaluated following ISO 10993-5 guidelines and L929 cell viability was calculated at ≥90% in the presence of MAAC. This study demonstrates that the MAAC could prevent bacterial contamination as demonstrated by the ISO 22196 tests, while further work needs to be done to improve the coating processability and effectiveness of more complex matrices.

1 April 2020 in Transfusion
Verified
Journal Article
Closed access
PDF file
JRJonathan Robidoux
Jonathan Robidoux
ALAudrey Laforce‐Lavoie
Audrey Laforce‐Lavoie
SCSteve J. Charette
Steve J. Charette
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
TYTatsuro Yoshida
Tatsuro Yoshida
DBDanny Brouard
Danny Brouard

13 April 2017 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
STSiyu Tu
Siyu Tu
DRDavid Rioux
David Rioux
JPJosée Perreault
Josée Perreault
DBDanny Brouard
Danny Brouard
MMMichel Meunier
Michel Meunier

31 December 2007 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
DBDanny Brouard
Danny Brouard
JGJean-François Y. Gravel
Jean-François Y. Gravel
MVMathieu Lessard Viger
Mathieu Lessard Viger
DBDenis Boudreau
Denis Boudreau

3 December 2014 in Vox Sanguinis
Verified
Journal Article
Closed access
PDF file
DBDanny Brouard
Danny Brouard
ORO. Ratelle
O. Ratelle
JPJ. Perreault
J. Perreault
DBDenis Boudreau
Denis Boudreau
MSM. St‐Louis
M. St‐Louis