1 April 2020 in Transfusion
9 April 2024 in Transfusion
Background: A life‐threatening anaphylactic shock can occur if a patient with undiagnosed immunoglobulin A (IgA) deficiency (i.e., IgA levels <500 ng/mL) receives IgA‐containing blood, hence the need for a rapid, point‐of‐care (POC) method for IgA deficiency screening. Enzyme‐linked immunosorbent assay (ELISA) is routinely used to detect IgA, but this method requires trained specialists and ≥24 h to obtain a result. We developed a surface plasmon resonance (SPR)‐based protocol to identify IgA‐deficient patients or donors within 1 h.Materials and Methods: The SPR sensor relies on the detection of IgAs captured by primary antibodies adsorbed on the SPR chip and quantified with secondary antibodies. The sensor was calibrated from 0 to 2000 ng/mL in buffer, IgA‐depleted human serum, and plasma samples from IgA‐deficient individuals. A critical concentration of 500 ng/mL was set for IgA deficiency. The optimized sensor was then tested on eight plasma samples with known IgA status (determined by ELISA), including five with IgA deficiency and three with normal IgA levels.Results: The limit of detection was estimated at 30 ng/mL in buffer and 400 ng/mL in diluted plasma. The results obtained fully agreed with ELISA among the eight plasma samples tested. The protocol distinguished IgA‐deficient from normal samples, even for samples with an IgA concentration closer to critical concentration.Discussion: In conclusion, we developed a reliable POC assay for the quantification of IgA in plasma. This test may permit POC testing at blood drives and centralized centers to maintain reserves of IgA‐deficient blood and in‐hospital testing of blood recipients.
22 October 2025 in PLOS ONE
Platelet concentrates (PCs) are stored at 20–24˚C in a biologically favorable environment that may support bacterial growth. Staphylococcus epidermidis , a typical contaminant, can form biofilms in PCs, complicating detection and increasing the risk of transfusion-transmitted bacterial infections. The material composition and surface texture of PC storage bags may influence biofilm formation. The impact of different PC storage bag materials on S. epidermidis biofilm formation was evaluated using the ISO 4768:2023(E) crystal violet (CV) assay. Four surface conditions were tested: polyvinyl chloride (PVC) plasticized with n-butyryl-tri(n-hexyl)-citrate (BTHC) – both smooth and rough sides, PVC plasticized with tri-(2-ethylhexyl)-trimellitate (TEHTM) and ethylene-vinyl acetate (EVA). Coupons and bags made from each material were used in the experiments. Biofilm-positive S. epidermidis was cultured in tryptic soy broth (TSB), PCs and plasma and added on plastic coupons under static conditions or directly in the bags with agitation. Bacterial enumeration and CV assay were performed on days 2, 5, and 7. In TSB, EVA coupons significantly formed more biofilm than the smooth side of PVC-BTHC or TEHTM over seven days. In PCs, more biofilm formed on the rough side of PVC-BTHC coupons than the smooth side, with no other differences between plastics, suggesting similar biofilm amount across PC bag materials in the presence of platelets. No biofilm was detected on coupons in plasma. Under continuous agitation and reduced oxygen levels, only the rough side of PVC-BTHC showed significant biofilm formation in TSB in PC storage bags over seven days. These findings highlight the need for standardized biofilm testing and suggest that some plastics are more conducive to biofilm formation under static conditions. However, during blood bank storage (i.e., continuous agitation and reduced oxygen levels), biofilm formation is limited, regardless of the platelet bag material, thereby reducing the risk of undetected bacterial contamination.
30 May 2025 in The Microbe