Vikas Gulani

Dr. Vikas Gulani

Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Radiology
Verified
Journal Article
Closed access
YCYong Chen
Yong Chen
YJYun Jiang
Yun Jiang
SPShivani Pahwa
Shivani Pahwa
DMDan Ma
Dan Ma
LLLan Lu
Lan Lu
VGVikas Gulani
Vikas Gulani
A rapid technique for quantitative abdominal imaging was developed by using a fast imaging with steady-state free precession MR fingerprinting acquisition in combination with the Bloch-Siegert B1 mapping method, allowing simultaneous quantification of T1 and T2 in the abdomen within a 19-second breath hold. PurposeTo develop a magnetic resonance (MR) “fingerprinting” technique for quantitative abdominal imaging.Materials and MethodsThis HIPAA-compliant study had institutional review board approval, and informed consent was obtained from all subjects. To achieve accurate quantification in the presence of marked B0 and B1 field inhomogeneities, the MR fingerprinting framework was extended by using a two-dimensional fast imaging with steady-state free precession, or FISP, acquisition and a Bloch-Siegert B1 mapping method. The accuracy of the proposed technique was validated by using agarose phantoms. Quantitative measurements were performed in eight asymptomatic subjects and in six patients with 20 focal liver lesions. A two-tailed Student t test was used to compare the T1 and T2 results in metastatic adenocarcinoma with those in surrounding liver parenchyma and healthy subjects.ResultsPhantom experiments showed good agreement with standard methods in T1 and T2 after B1 correction. In vivo studies demonstrated ...

29 December 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
CBC. Badve
C. Badve
AYA. Yu
A. Yu
SDS. Dastmalchian
S. Dastmalchian
MRM. Rogers
M. Rogers
DMD. Ma
D. Ma
VGVikas Gulani
Vikas Gulani
BACKGROUND AND PURPOSE: MR fingerprinting allows rapid simultaneous quantification of T1 and T2 relaxation times. This study assessed the utility of MR fingerprinting in differentiating common types of adult intra-axial brain tumors. MATERIALS AND METHODS: MR fingerprinting acquisition was performed in 31 patients with untreated intra-axial brain tumors: 17 glioblastomas, 6 World Health Organization grade II lower grade gliomas, and 8 metastases. T1, T2 of the solid tumor, immediate peritumoral white matter, and contralateral white matter were summarized within each ROI. Statistical comparisons on mean, SD, skewness, and kurtosis were performed by using the univariate Wilcoxon rank sum test across various tumor types. Bonferroni correction was used to correct for multiple-comparison testing. Multivariable logistic regression analysis was performed for discrimination between glioblastomas and metastases, and area under the receiver operator curve was calculated. RESULTS: Mean T2 values could differentiate solid tumor regions of lower grade gliomas from metastases (mean, 172 ± 53 ms, and 105 ± 27 ms, respectively; P = .004, significant after Bonferroni correction). The mean T1 of peritumoral white matter surrounding lower grade gliomas differed from peritumoral white matter around glioblastomas (mean, 1066 ± 218 ms, and 1578 ± 331 ms, respectively; P = .004, significant after Bonferroni correction). Logistic regression analysis revealed that the mean T2 of solid tumor offered the best separation between glioblastomas and metastases with an area under the curve of 0.86 (95% CI, 0.69–1.00; P < .0001). CONCLUSIONS: MR fingerprinting allows rapid simultaneous T1 and T2 measurement in brain tumors and surrounding tissues. MR fingerprinting–based relaxometry can identify quantitative differences between solid tumor regions of lower grade gliomas and metastases and between peritumoral regions of glioblastomas and lower grade gliomas.

1 August 2019 in Radiology
Verified
Journal Article
Closed access
GKGregor Koerzdoerfer
Gregor Koerzdoerfer
RKRainer Kirsch
Rainer Kirsch
KLKecheng Liu
Kecheng Liu
JPJosef Pfeuffer
Josef Pfeuffer
BHBernhard Hensel
Bernhard Hensel
MNMathias Nittka
Mathias Nittka
Relaxation times in solid compartments of the human brain measured with fast imaging with steady-state free precession MR fingerprinting varied less than 8.0% (95% confidence intervals: −8.0%, 8.0%... Background Only sparse literature investigates the reproducibility and repeatability of relaxometry methods in MRI. However, statistical data on reproducibility and repeatability of any quantitativ...

1 September 2017 in Current Opinion in Biomedical Engineering
Verified
Journal Article
Closed access
APAnanya Panda
Ananya Panda
BMBhairav B. Mehta
Bhairav B. Mehta
SCSimone Coppo
Simone Coppo
YJYun Jiang
Yun Jiang
DMDan Ma
Dan Ma
VGVikas Gulani
Vikas Gulani

1 January 2019 in Radiology
Verified
Journal Article
Closed access
YCYong Chen
Yong Chen
APAnanya Panda
Ananya Panda
SPShivani Pahwa
Shivani Pahwa
JHJesse I. Hamilton
Jesse I. Hamilton
SDSara Dastmalchian
Sara Dastmalchian
VGVikas Gulani
Vikas Gulani
A method was developed for breast imaging by using the MR fingerprinting technique, which allows simultaneous and volumetric quantification of T1 and T2 relaxation times for breast tissues. PurposeTo develop a fast three-dimensional method for simultaneous T1 and T2 quantification for breast imaging by using MR fingerprinting.Materials and MethodsIn this prospective study, variable flip angles and magnetization preparation modules were applied to acquire MR fingerprinting data for each partition of a three-dimensional data set. A fast postprocessing method was implemented by using singular value decomposition. The proposed technique was first validated in phantoms and then applied to 15 healthy female participants (mean age, 24.2 years ± 5.1 [standard deviation]; range, 18–35 years) and 14 female participants with breast cancer (mean age, 55.4 years ± 8.8; range, 39–66 years) between March 2016 and April 2018. The sensitivity of the method to B1 field inhomogeneity was also evaluated by using the Bloch-Siegert method.ResultsPhantom results showed that accurate and volumetric T1 and T2 quantification was achieved by using the proposed technique. The acquisition time for three-dimensional quan...

1 November 2018 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
JHJesse I. Hamilton
Jesse I. Hamilton
YJYun Jiang
Yun Jiang
DMDan Ma
Dan Ma
WLWei-Ching Lo
Wei-Ching Lo
VGVikas Gulani
Vikas Gulani
NSNicole Seiberlich
Nicole Seiberlich