Carlos Andrés Vázquez

Prof. Carlos Andrés Vázquez

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Expert Systems with Applications
Verified
Journal Article
Closed access
CVCarlos Andrés Vázquez
Carlos Andrés Vázquez
CLCristina Losada-Gutiérrez
Cristina Losada-Gutiérrez
DJDavid Fuentes Jiménez
David Fuentes Jiménez
AFAlvaro Fernandez-Rincon
Alvaro Fernandez-Rincon
MMManuel Mazo
Manuel Mazo
JMJavier Macias-Guarasa
Javier Macias-Guarasa

31 July 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
JLJean-Marc Lavest
Jean-Marc Lavest
CVCarlos Andrés Vázquez
Carlos Andrés Vázquez
AVAlfredo Gardel Vicente
Alfredo Gardel Vicente
IMIgnacio Bravo Munoz
Ignacio Bravo Munoz
We present an advanced method of system calibration measurement to improve the precision in obtaining measurements of 3-D coordinates. This system is comprised of a CMOS array sensor and an infrared (IR) emitter. Improving the accuracy requires improving the method of sensor calibration. In this paper, a process of calibrating systems for geometry determination and positioning a mobile robot is developed. The system calibration method uses the perspective projection model based on the pinhole model, taking into account the intrinsic and extrinsic parameters of the camera together with the parameters of the pattern plane. We also consider the distortion effects of the lenses and the errors obtained in detection. To run the method, the applied calibration pattern is a planar surface with several circular points. The CMOS camera is equipped with a short-focal-length lens.

1 July 2010
Verified
Conference Paper
Closed access
CVCarlos Andrés Vázquez
Carlos Andrés Vázquez
MQM. Mazo Quintas
M. Mazo Quintas
MRM. Marron Romera
M. Marron Romera
This paper presents a sensor system used to measure the height variations of the overhead contact wire feeding electric traction trains when a pantograph is passing. These measures are used to determine the occurrence of defects in the catenary-pantograph interaction. The non-contact sensor for monitoring catenary-pantograph interaction (NCCPI) system consists of a line-scan camera focused to an infrared screen, so that the contact wire is within the viewing plane of the line-scan. The screen is comprised of a light illuminated area and four black areas, which are used as a reference for determining the height of the wire. The measures are taken in differential form, diminishing the effect of vibrations and changes in lighting. The paper shows the mathematical model of the sensor system and the practical results obtained.

17 January 2022 in Toxics
Verified
Journal Article
Open access
PDF file
MDMABEL DIAZ-CUBILLA
MABEL DIAZ-CUBILLA
PLPedro Letón
Pedro Letón
CVCarlos Andrés Vázquez
Carlos Andrés Vázquez
MMMarta Marrón-Romera
Marta Marrón-Romera
Karina BoltesKarina Boltes
Karina Boltes
Pharmaceuticals and personal care products (PPCPs) are partially degraded in wastewater treatment plants (WWTPs), thereby leading to the formation of more toxic metabolites. Bacterial populations in bioreactors operated in WWTPs are sensitive to different toxics such as heavy metals and aromatic compounds, but there is still little information on the effect that pharmaceuticals exert on their metabolism, especially under anaerobic conditions. This work evaluated the effect of selected pharmaceuticals that remain in solution and attached to biosolids on the metabolism of anaerobic biomass. Batch reactors operated in parallel under the pressure of four individual and mixed PPCPs (carbamazepine, ibuprofen, triclosan and sulfametoxazole) allowed us to obtain relevant information on anaerobic digestion performance, toxicological effects and alterations to key enzymes involved in the biodegradation process. Cell viability was quantitatively evaluated using an automatic analysis of confocal microscopy images, and showed that triclosan and mixed pollutants caused higher toxicity and cell death than the other individual compounds. Both individual pollutants and their mixture had a considerable impact on the anaerobic digestion process, favoring carbon dioxide production, lowering organic matter removal and methane production, which also produced microbial stress and irreversible cell damage.

30 January 2006 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CVCarlos Andrés Vázquez
Carlos Andrés Vázquez
MMM. Mazo
M. Mazo
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
JVJ.F. Vasquez
J.F. Vasquez
Jesús UreñaJesús Ureña
Jesús Ureña
ESEnrique Santiso
Enrique Santiso
In the measurement systems of three-dimensional (3-D) positions using active vision (e.g., laser and camera), it is necessary to know the precise rotation angles of the camera and the laser with respect to the object on which the 3-D coordinate measures are desired. A small variation of these angles can result in substantial errors of measurement. In this work, we present a novel solution to measure the rotation-angle variations of the elements that form the measurement system under vibration. In our case, the objective is to determine these angles for a 3-D-coordinate measurement system of the wires that feed the electric trains (contact wires). The measurement system must go onboard a measurement car. The 3-D-coordinate measurements are done by triangulation, from a digital camera and a laser that emits a plane of structured light incident on contact wires. In order to measure the angle variations, which result from the vibrations that take place in the measurement system, two line scan cameras and two artificial marks are used. In this paper, the procedure that allows the measurement of the rotation angles of the camera and the laser, the proposed models, and the results obtained in the simulations are shown.

1 April 2021 in Expert Systems with Applications
Verified
Journal Article
Closed access
CVCarlos Andrés Vázquez
Carlos Andrés Vázquez
CLCristina Losada-Gutiérrez
Cristina Losada-Gutiérrez
DJDavid Fuentes Jiménez
David Fuentes Jiménez
MMManuel Mazo
Manuel Mazo