Dr. José Luis Lázaro-Galilea

Prof. Dr. José Luis Lázaro-Galilea

Department of Electronics, Polytechnic School Office O-334, University of Alcalá, Campus Universitario, 28871 – Alcalá, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2011 in Sensors
Verified
Journal Article
Open access
PDF file
EMErnesto Martín-Gorostiza
Ernesto Martín-Gorostiza
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
FMFranciso Javier Meca Meca
Franciso Javier Meca Meca
DMDavid Salido Monzú
David Salido Monzú
FZFelipe Espinosa Zapata
Felipe Espinosa Zapata
LPLuis Pallarés Puerto
Luis Pallarés Puerto
The aim of this work was to position a Mobile Robot in an Intelligent Space, and this paper presents a sensorial system for measuring differential phase-shifts in a sinusoidally modulated infrared signal transmitted from the robot. Differential distances were obtained from these phase-shifts, and the position of the robot was estimated by hyperbolic trilateration. Due to the extremely severe trade-off between SNR, angle (coverage) and real-time response, a very accurate design and device selection was required to achieve good precision with wide coverage and acceptable robot speed. An I/Q demodulator was used to measure phases with one-stage synchronous demodulation to DC. A complete set of results from real measurements, both for distance and position estimations, is provided to demonstrate the validity of the system proposed, comparing it with other similar indoor positioning systems.

6 July 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JGJorge García
Jorge García
ALFREDO GARDEL-VICENTEALFREDO GARDEL-VICENTE
ALFREDO GARDEL-VICENTE
IGNACIO BRAVOIGNACIO BRAVO
IGNACIO BRAVO
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
MMMiguel Martinez
Miguel Martinez
DRDavid Rodriguez
David Rodriguez
This paper presents an application for counting people through a single fixed camera. This system performs the count distinction between input and output of people moving through the supervised area. The counter requires two steps: detection and tracking. The detection is based on finding people's heads through preprocessed image correlation with several circular patterns. Tracking is made through the application of a Kalman filter to determine the trajectory of the candidates. Finally, the system updates the counters based on the direction of the trajectories. Different tests using a set of real video sequences taken from different indoor areas give results ranging between 87% and 98% accuracies depending on the volume of flow of people crossing the counting zone. Problematic situations, such as occlusions, people grouped in different ways, scene luminance changes, etc., were used to validate the performance of the system.

1 April 2016 in Expert Systems with Applications
Verified
Journal Article
Closed access
FDFrancisco Domingo-Perez
Francisco Domingo-Perez
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
AWAndreas Wieser
Andreas Wieser
EMErnesto Martin-Gorostiza
Ernesto Martin-Gorostiza
DMDavid Salido Monzú
David Salido Monzú
ÁDÁlvaro De-La-Llana-Calvo
Álvaro De-La-Llana-Calvo

1 January 1995 in Autonomous Robots
Verified
Journal Article
Closed access
PDF file
MMManuel Mazo
Manuel Mazo
ESEnrique Santiso
Enrique Santiso
Pedro RevengaPedro Revenga
Pedro Revenga
FRFrancisco J. Rodríguez
Francisco J. Rodríguez
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
JGJ. Jesus Garcia
J. Jesus Garcia

13 October 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CLC A Luna
C A Luna
MMManuel Mazo
Manuel Mazo
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
JVJuan F. Vazquez
Juan F. Vazquez
This paper presents a novel method for calibrating line-scan cameras using a calibration pattern comprising two parallel planes with lines that can be described using known equations. Using pattern geometry and a line that is captured by a line-scan camera, we calculate the 3-D coordinates of the points corresponding to the straight lines of a pattern that is captured by the line-scan camera. These coordinates are used to obtain the intrinsic and extrinsic parameters of the line scan using a standard calibration procedure that is based on a recursive least squares method. In this paper, the procedure of calibration and the results obtained for a specific line scan will be shown; specifically, the obtained median residual error is 0.28 pixel. Also, the repetitiveness of the calibration process was verified for a sequence of 500 times.

1 May 1995 in Control Engineering Practice
Verified
Journal Article
Closed access
MMM. Mazo
M. Mazo
FRF.J. Rodríguez
F.J. Rodríguez
Dr. José Luis Lázaro-GalileaDr. José Luis Lázaro-Galilea
Dr. José Luis Lázaro-Galilea
Jesús UreñaJesús Ureña
Jesús Ureña
JGJ. Jesus Garcia
J. Jesus Garcia
Pedro RevengaPedro Revenga
Pedro Revenga