Maxim Grigoriev

Dr. Maxim Grigoriev

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
NAN. P. Aleshin
N. P. Aleshin
VMV. V. Murashov
V. V. Murashov
AEA. G. Evgenov
A. G. Evgenov
MGMaxim Grigoriev
Maxim Grigoriev
SNShchipakov Nikita
Shchipakov Nikita
IKI. S. Krasnov
I. S. Krasnov

31 December 2003
Verified
Conference Paper
Closed access
PDF file
ASA Snigirev
A Snigirev
ISIrina Snigireva
Irina Snigireva
MDMichael Drakopoulos
Michael Drakopoulos
VNVladimir Nazmov
Vladimir Nazmov
ERElena Reznikova
Elena Reznikova
VSVolker Saile
Volker Saile
Compound refractive lenses printed in Al and Be are becoming the key X-ray focusing and imaging components of beamline optical layouts at the 3rd generation synchrotron radiation sources. Recently proposed planar optical elements based on Si, diamond etc. may substantially broaden the spectrum of the refractive optics applicability. Planar optics has focal distances ranging from millimeters to tens of meters offering nano- and micro-focusing lenses, as well as beam condensers and collimators. Here we promote deep X-ray lithography and LIGA-type techniques to create high aspect-ratio lens structures for different optical geometries. Planar X-ray refractive lenses were manufactured in 1 mm thick SU-8 negative resist layer by means of deep synchrotron radiation lithography. The focusing properties of lenses were studied at ID18F and BM5 beamlines at the ESRF using monochromatic radiation in the energy range of 10 - 25 keV. By optimizing lens layout, mask making and resist processing, lenses of good quality were fabricated. The resolution of about 270 nm (FWHM) with gain in the order of 300 was measured at 14 keV. In-line holography of B-fiber was realized in imaging and projection mode with a magnification of 3 and 20, respectively. Submicron features of the fiber were clearly resolved. A radiation stability test proved that the fabricated lenses don't change focusing characteristics after dose of absorbed X-ray radiation of about 2 MJ/cm3. The unique radiation stability along with the high effficiency of SU8 lenses opens wide range of their synchrotron radiation applications such as microfocusing elements, condensers and collimators.

1 February 2021 in Computer Optics
Verified
Journal Article
Closed access
FSFsrc
Fsrc
MCMarina Chukalina
Marina Chukalina
CPCrystallography And Photonics
Crystallography And Photonics
RARas
Ras
SLSmart Engines Llc
Smart Engines Llc
ISInstitute of Microelectronics Technology and High-Purity Materials of the Russian Academy of Sciences
Institute of Microelectronics Technology and High-Purity Materials of the Russian Academy of Sciences
An algorithm for post-processing of the grayscale 3D computed tomography (CT) images of porous structures with the automatic selection of filtering parameters is proposed. The determination of parameters is carried out on a representative part of the image under analysis. A criterion for the search for optimal filtering parameters based on the count of "levitating stone" voxels is described. The stages of CT image filtering and its binarization are performed sequentially. Bilateral and anisotropic diffuse filtering is implemented; the Otsu method for unbalanced classes is chosen for binarization. Verification of the proposed algorithm was carried out on model data. To create model porous structures, we used our image generator, which implements the function of anisotropic porous structures generation. Results of the post-processing of real CT images containing noise and reconstruction artifacts by the proposed method are discussed.

27 May 2020 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
DZDenis Zolotov
Denis Zolotov
ABAlexey Buzmakov
Alexey Buzmakov
MGMaxim Grigoriev
Maxim Grigoriev
ISIgor Schelokov
Igor Schelokov

18 April 2022 in IEEE Access
Verified
Journal Article
Open access
ABAlexey Buzmakov
Alexey Buzmakov
YKYuri Krivonosov
Yuri Krivonosov
MGMaxim Grigoriev
Maxim Grigoriev
EMEvgeny Mogilevskiy
Evgeny Mogilevskiy
MCMarina Chukalina
Marina Chukalina
VAVictor Asadchikov
Victor Asadchikov
In this paper, a new method for the mathematical tomographic reconstruction of time-varying objects (4D tomography) is presented. The method is applicable under the conditions that the amount of substance at each spatial point does not decrease, and only one projection image is available per time point during the process of the object changing. The temporal resolution of the proposed method is obtained by using an iterative approach to reconstruction. Prior knowledge about object morphology is exploited to improve the convergence of the algorithm by reducing the number of processed spatial points. Verification of the algorithm operation was carried out using model examples. The presented method was experimentally tested on the tomographic reconstruction of the dynamics of the capillary rise of a liquid. Our experiments demonstrated that monitoring fast processes, when the speed of the process does not allow to measure more than one tomographic projection, is potentially possible.

14 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MGMaxim Grigoriev
Maxim Grigoriev
DZDenis Zolotov
Denis Zolotov
AIAnastasia Ingacheva
Anastasia Ingacheva
ABAlexey Buzmakov
Alexey Buzmakov
IDIrina Dyachkova
Irina Dyachkova
MCMarina Chukalina
Marina Chukalina
To solve the problems of spectral tomography, an X-ray optical scheme was proposed, using a crystal analyzer in Laue geometry between the sample and the detector, which allowed for the selection of predetermined pairs of wavelengths from the incident polychromatic radiation to obtain projection images. On a laboratory X-ray microtomography setup, an experiment was carried out for the first time where a mixture of micro-granules of sodium chloride NaCl, silver behenate AgC22H43O2, and lithium niobate LiNbO3 was used as a test sample to identify their spatial arrangement. The elements were chosen based on the presence of absorption edges in two of the elements in the energy range of the polychromatic spectrum of the probing radiation. The method of projection distortion correction was used to preprocess the obtained projections. To interpret the obtained reconstruction results, the segmentation method based on the analysis of joint histograms was used. This allowed us to identify each of the three substances. To compare the results obtained, additional “reference” tomographic measurements were performed: one in polychromatic and two in monochromatic (MoKα-, MoKβ-lines) modes. It took three times less time for the tomographic experiment with the crystal analyzer, while the reconstruction accuracy was comparable to that of the “reference” tomography.