Irina Dyachkova

Dr. Irina Dyachkova

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
VAVictor Asadchikov
Victor Asadchikov
ABAlexey Buzmakov
Alexey Buzmakov
Felix ChukhovskiiFelix Chukhovskii
Felix Chukhovskii
IDIrina Dyachkova
Irina Dyachkova
DZDenis Zolotov
Denis Zolotov
ESErnest Suvorov
Ernest Suvorov

11 March 2022 in Dental Materials
Verified
Journal Article
Open access
VLVarvara Labis
Varvara Labis
EBErnest Bazikyan
Ernest Bazikyan
OZOlga Zhigalina
Olga Zhigalina
SSSvetlana Sizova
Svetlana Sizova
VOVladimir Oleinikov
Vladimir Oleinikov
IKIvan Kozlov
Ivan Kozlov
To study the oxide layer stability of certified dental implants of system "P", made based on TiO2 alloy with carbon coating. To perform a comparative statistical analysis of the obtained data with the available data for the dental implants of systems "A" and "B". X-ray microtomography and X-ray fluorescence analysis were used to study soft tissue biopsy specimens. Supernatants were studied by dynamic light scattering and transmission electron microscopy when simulating free emission of nanoscale metal oxide particles from the surface of dental implants as well as when simulating physical loading. A comparative analysis of three parameters of nanoscale particles was performed by statistical data analysis. The surface of the "P" system dental implant with surface treatment was analyzed by scanning electron microscopy. Both free emission of nanoscale oxide layer particles and yield of nano- and microscale particles during simulation of physical load were confirmed. Statistically significant differences were noted in a comparative analysis of the size and frequency of occurrence of these particles in the supernatants obtained from the surfaces of three dental implant systems. The elemental composition of the particles and the composition and structure of the "P" system dental implants themselves were analyzed. The developed method of dynamic light scattering can be used to compare the stability of the oxide layer of standardized medical products manufactured on the basis of the TiO2 alloy.

25 March 2021 in Polymers
Verified
Journal Article
Open access
PDF file
ABAlexey Buzmakov
Alexey Buzmakov
ADAndrey Gennad'evich Dunaev
Andrey Gennad'evich Dunaev
YKYuri Stanislavovich Krivonosov
Yuri Stanislavovich Krivonosov
DZDenis Zolotov
Denis Zolotov
IDIrina Dyachkova
Irina Dyachkova
Vladimir K. PopovVladimir K. Popov
Vladimir K. Popov
In this study, the nanoscale transformation of the polylactic-co-glycolic acid (PLGA) internal structure, before and after its supercritical carbon dioxide (sc-CO2) swelling and plasticization, followed by foaming after a CO2 pressure drop, was studied by small-angle X-ray scattering (SAXS) for the first time. A comparative analysis of the internal structure data and porosity measurements for PLGA scaffolds, produced by sc-CO2 processing, on a scale ranging from 0.02 to 1000 μm, was performed by SAXS, helium pycnometry (HP), mercury intrusion porosimetry (MIP) and both “lab-source” and synchrotron X-ray microtomography (micro-CT). This approach opens up possibilities for the wide-scale evaluation, computer modeling, and prediction of the physical and mechanical properties of PLGA scaffolds, as well as their biodegradation behavior in the body. Hence, this study targets optimizing the process parameters of PLGA scaffold fabrication for specific biomedical applications.

29 September 2023 in Photonics
Verified
Journal Article
Open access
PDF file
EMEvgenii Mareev
Evgenii Mareev
AGAlena Garmatina
Alena Garmatina
TSTimur Semenov
Timur Semenov
NANika Asharchuk
Nika Asharchuk
VRVladimir Rovenko
Vladimir Rovenko
IDIrina Dyachkova
Irina Dyachkova
Progress in the field of machine learning has enhanced the development of self-adjusting optical systems capable of autonomously adapting to changing environmental conditions. This study demonstrates the concept of self-adjusting optical systems and presents a new approach based on reinforcement learning methods. We integrated reinforcement learning algorithms into the setup for tuning the laser radiation into the fiber, as well as into the complex for controlling the laser-plasma source. That reduced the dispersion of the generated X-ray signal by 2–3 times through automatic adjustment of the position of the rotating copper target and completely eliminated the linear trend arising from the ablation of the target surface. The adjustment of the system was performed based on feedback signals obtained from the spectrometer, and the movement of the target was achieved using a neural network-controlled stepper motor. As feedback, the second harmonic of femtosecond laser radiation was used, the intensity of which has a square root dependence on the X-ray yield. The developed machine learning methodology allows the considered systems to optimize their performance and adapt in real time, leading to increased efficiency, accuracy, and reliability.

Verified
Journal Article
Open access
PDF file
VLVarvara Vladimirovna Labis
Varvara Vladimirovna Labis
EBErnest Bazikyan
Ernest Bazikyan
SSSvetlana Sizova
Svetlana Sizova
VOVladimir A. Oleinikov
Vladimir A. Oleinikov
ATAndrey Trulioff
Andrey Trulioff
IKIvan Genrikhovich Kozlov
Ivan Genrikhovich Kozlov
The purpose of this study was to provide an immuno-mediated substantiation of the etiopathogenesis of mucositis and peri-implantitis based on the results of experimental, laboratory and clinical studies. The biopsy material was studied to identify impregnated nanoscale and microscale particles in the structure of pathological tissues by using X-ray microtomography and X-ray fluorescence analyses. Electron microscopy with energy-dispersive analysis identified the composition of supernatants containing nanoscale metal particles obtained from the surfaces of dental implants. The parameters of the nanoscale particles were determined by dynamic light scattering. Flow cytometry was used to study the effect of nanoscale particles on the ability to induce the activation and apoptosis of immunocompetent cells depending on the particles’ concentrations during cultivation with the monocytic cell line THP-1 with the addition of inductors. An analysis of the laboratory results suggested the presence of dose-dependent activation, as well as early and late apoptosis of the immunocompetent cells. Activation and early and late apoptosis of a monocytic cell line when THP-1 was co-cultured with nanoscale metal particles in supernatants were shown for the first time. When human venous blood plasma was added, both activation and early and late apoptosis had a dose-dependent effect and differed from those of the control groups.

13 December 2023 in Optics Express
Verified
Journal Article
Closed access
AGAlena Garmatina
Alena Garmatina
EMEvgenii Mareev
Evgenii Mareev
NMNikita Minaev
Nikita Minaev
NANika Asharchuk
Nika Asharchuk
TSTimur Semenov
Timur Semenov
VAVictor Asadchikov
Victor Asadchikov
Radiographic imaging using X-rays is a tool for basic research and applications in industry, materials science, and medical diagnostics. In this article, we present a novel approach for the generation of X-rays using a vacuum-free microplasma by femtosecond fiber laser. By tightly focusing a laser pulse onto a micrometer-sized solid density near-surface plasma from a rotating copper target, we demonstrate the generation of Cu K-photons (8-9 keV) with high yield ∼ 1.6 × 109 phot/s/2π, and with a source size diameter of approximately 10 microns. Femtosecond fiber laser allows working with a high repetition rate (∼2 MHz) and moderate energy levels (10-40 µJ), ensuring the effective quasi-continuous generation of X-ray photons. Furthermore, we introduce a hybrid scheme that combines the tightly focusing laser-plasma X-ray generator with an online control unit for microplasma size source based on the back-reflected second harmonic generated in the laser-induced microplasma. The compactness and high performance of this vacuum-free femtosecond fiber laser microplasma X-ray source makes it a promising solution for advanced radiographic applications. Our preliminary results on the creation of a microfocus X-ray source provide insights into the feasibility and potential of this innovative approach.