Jinlei Chen

Mr. Jinlei Chen

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JCJinlei Chen
Jinlei Chen
WMWenlong Ming
Wenlong Ming
Carlos E Ugalde-LooCarlos E Ugalde-Loo
Carlos E Ugalde-Loo
SWSheng Wang
Sheng Wang
NJNick Jenkins
Nick Jenkins
The cascaded three-level neutral-point-clamped (3L-NPC) converter and the modular multilevel converter (MMC) are attractive solutions for medium-voltage direct-current (MVdc) applications. Due to their low cost compared to MMCs, cascaded 3L-NPC converters have been adopted in ANGLE-DC—a 30-MVA MVdc link demonstration project in North Wales, U.K. The dc voltage imbalance across submodules (SMs) is a common challenge for both types of MVdc converters. Such imbalance is topology dependent and remains underresearched for cascaded 3L-NPC converters. In this article, a small-signal model-based analysis has been done to reveal that the dc voltage imbalance in cascaded 3L-NPC converters is caused by an unstable system pole. Two voltage balancing methods are presented. The first method is based on PI controllers to precisely regulate SMs’ voltages without influencing output power. However, it relies on communication between a central controller and local controllers within SMs. The second method uses inverse-droop-based control to take over the dc voltage regulation upon loss of communication. Both balancing methods are experimentally validated using a 30-kVA testbed based on the ANGLE-DC project. It has been demonstrated that the dc voltages of SMs can be effectively balanced with both methods during changes of load conditions and dc bus voltages.

28 January 2023 in New Forests
Verified
Journal Article
Closed access
PDF file
JCJinlei Chen
Jinlei Chen
XFXi Fang
Xi Fang
AWAnchi Wu
Anchi Wu
WXWenhua Xiang
Wenhua Xiang
PLPifeng Lei
Pifeng Lei
SOShuai Ouyang
Shuai Ouyang

6 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
JCJinlei Chen
Jinlei Chen
SWSheng Wang
Sheng Wang
Carlos E Ugalde-LooCarlos E Ugalde-Loo
Carlos E Ugalde-Loo
WMWenlong Ming
Wenlong Ming
OAOluwole D. Adeuyi
Oluwole D. Adeuyi
IAIñigo Azpiri
Iñigo Azpiri
Although the control of modular multi-level converters (MMCs) in high-voltage direct-current (HVDC) networks has become a mature subject these days, the potential for adverse interactions between different converter controls remains an under-researched challenge attracting the attention from both academia and industry. Even for point-to-point HVDC links (i.e., simple HVDC systems), converter control interactions may result in the shifting of system operating voltages, increased power losses, and unintended power imbalances at converter stations. To bridge this research gap, the risk of multiple cross-over of control characteristics of MMCs is assessed in this paper through mathematical analysis, computational simulation, and experimental validation. Specifically, the following point-to-point HVDC link configurations are examined: (1) one MMC station equipped with a current versus voltage droop control and the other station equipped with a constant power control; and (2) one MMC station equipped with a power versus voltage droop control and the other station equipped with a constant current control. Design guidelines for droop coefficients are provided to prevent adverse control interactions. A 60-kW MMC test-rig is used to experimentally verify the impact of multiple crossing of control characteristics of the DC system configurations, with results verified through software simulation in MATLAB/Simulink using an open access toolbox. Results show that in operating conditions of 650 V and 50 A (DC voltage and DC current), drifts of 7.7% in the DC voltage and of 10% in the DC current occur due to adverse control interactions under the current versus voltage droop and power control scheme. Similarly, drifts of 7.7% both in the DC voltage and power occur under the power versus voltage droop and current control scheme.

16 August 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JCJinlei Chen
Jinlei Chen
SWSheng Wang
Sheng Wang
Carlos E Ugalde-LooCarlos E Ugalde-Loo
Carlos E Ugalde-Loo
JLJun LIANG
Jun LIANG
ILIngo Lüdtke
Ingo Lüdtke
WMWenlong Ming
Wenlong Ming
The cascaded three-level neutral-point-clamped (C3L-NPC) converter has been adopted in practical projects for power transmission in medium-voltage distribution networks. However, this type of converter comprises multiple submodules (SMs) in which thermal imbalance may occur due to a mismatch between component parameters of the SMs. This may lead to decreased system reliability. To address this shortcoming, an active thermal sharing control strategy for C3L-NPC converters is presented in this paper. A thermal control loop is incorporated into the inner current controller within each SM. Active and reactive power regulation is conducted based on the individual junction temperature of each SM. A high-level controller is used to regulate the total power and to calculate the temperature reference. The control strategy enables decoupled thermal and power regulation, and each control loop can be independently designed. The effectiveness of the approach has been experimentally validated using a testbed down-scaled from the ANGLE-DC project—the first operational medium-voltage dc link in Europe. It is shown that the junction temperature of the SMs is effectively balanced without affecting the output power under cooling system failures.

20 April 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
JCJinlei Chen
Jinlei Chen
SWSheng Wang
Sheng Wang
JLJun LIANG
Jun LIANG
RNRukshan Navaratne
Rukshan Navaratne
WMWenlong Ming
Wenlong Ming
Decentralized control with multiple droop characteristics can significantly improve the accuracy of power flow in medium-voltage direct-current (MVdc) networks. However, multiple crossovers caused by different control characteristics can lead to the drifts of power and voltage and instability issues. When this type of control is implemented in the cascaded three-level neutral-point-clamped (C3L-NPC) converters, on one hand, the mechanism of such the power and voltage drifts was not investigated. On the other hand, power control accuracy, dc voltage balancing across submodules (SMs) and multiple crossovers should all be considered, which requires suitable control methods. To address the challenges, firstly, the mechanism behind the power and dc voltage drifts is analyzed. Secondly, a control scheme is presented to improve the power control accuracy and dc voltage balancing and concurrently, to avoid the multiple crossovers. This is achieved by suitable droop gain design and adding a secondary power compensator. The presented control scheme is verified in MATLAB/Simulink simulation and experimentally validated in a three-terminal MVdc testbed. Results show that the accuracy of steady-state power flow is improved by 15% due to the elimination of multiple crossovers, while the power accuracy at dynamics improved by 13% with the secondary power compensator.

19 May 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYidan Zhang
Yidan Zhang
JCJinlei Chen
Jinlei Chen
A key objective of the UK's first medium-voltage dc (MVdc) project, Angle-DC, is to reduce network losses, with converter losses (around 10%) presenting significant improvement potential. To reduce the converter's switching losses, this paper presents a power-routing based coordination control strategy for the interleaved input-series-output-parallel (ISOP) converter used in Angle-DC. The control method optimizes power redistribution across submodules (SMs), with high-power SMs operating at low switching frequencies to handle most power transmission, while a low-power auxiliary SM employs fast-response hysteresis control to mitigate the total current ripple, thus reducing losses without compromising output current performance. A hardware-in-the-loop (HIL) test validates the proposed approach, showing a 38% reduction in switching losses compared to conventional power balancing methods for a full-rating system. The effectiveness of the proposed control is further partially validated using a laboratory-scale testbed.