Lin Gui

Prof. Lin Gui

Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MGMeng Gao
Meng Gao
Lin GuiLin Gui
Lin Gui
A room temperature liquid metal based electroosmotic flow (EOF) pump has been proposed in this work. This low-cost EOF pump is convenient for both fabrication and integration. It utilizes polydimethylsiloxane (PDMS) microchannels filled with the liquid-metal as non-contact pump electrodes. The electrode channels are fabricated symmetrically to both sides of the pumping channel, having no contact with the pumping channel. To test the pumping performance of the EOF pump, the mean flow velocities of the fluid (DI water) in the EOF pumps were experimentally measured by tracing the fluorescent microparticles in the flow. To provide guidance for designing a low voltage EOF pump, parametric studies on dimensions of the electrode and pumping channels were performed in this work. According to the experimental results, the pumping speed can reach 5.93 μm s−1 at a driving voltage of only 1.6 V, when the gap between the electrode and the pumping channel is 20 μm. Injecting a room temperature liquid metal into microchannels can provide a simple, rapid, low-cost but accurately self-aligned way to fabricate microelectrodes for EOF pumps, which is a promising method to achieve the miniaturization and integration of the EOF pump in microfluidic systems. The non-contact liquid electrodes have no influence on the fluid in the pumping channel when pumping, reducing Joule heat generation and preventing gas bubble formation at the surface of electrodes. The pump has great potential to drive a wide range of fluids, such as drug reagents, cell suspensions and biological macromolecule solutions.

15 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LZLunjia Zhang
Lunjia Zhang
MGMeng Gao
Meng Gao
RWRonghang Wang
Ronghang Wang
ZDZhong-Shan Deng
Zhong-Shan Deng
Lin GuiLin Gui
Lin Gui
Nowadays, with the development of wearable devices, stretchable pressure sensors have been widely adopted in all kinds of areas. Most of the sensors aim to detect small pressure, such as fingertip tactile sensing, but only a few are focused on high-pressure sensing, such as foot pressure sensing during men’s walking. In this work, a liquid metal-based stretchable sensor for large-pressure measurement is investigated. This sensor is fully stretchable because it is made of soft materials. However, when the soft sensor is subjected to high pressure, the liquid metal easily leaks from microchannels because it maintains the liquid state at room temperature. We therefore propose to fabricate liquid metal-based leakage-free electrodes to handle the liquid-metal leak. Parametric studies are conducted to compare this sensor with liquid-metal-only electrodes and leakage-free electrodes. The leakage-free electrodes increase the measurement ranges from 0.18, 0.18, and 0.15 MPa to 0.44 MPa, with higher linearity and precision. The improvement in the liquid-metal electrode enables the sensors to work stably within 0.44 MPa pressure and 20% strain. In addition, we integrate two capacitors, namely, a working capacitor and a reference capacitor, into one sensor to reduce the influence of parasitic capacitance brought about by external interference. This stretchable capacitive sensor capable of working under a wide range of pressure with good repeatability, sensitivity, and linearity, exhibits great potential use for wearable electronics. Finally, the method for fabricating leakage-free electrodes shows great value for hyperelastic electronics manufacturing and micromachine technology.

27 January 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
LTLu Tian
Lu Tian
MGMeng Gao
Meng Gao
Lin GuiLin Gui
Lin Gui
A liquid metal based microfluidic system was proposed and demonstrated for the generation and sorting of liquid metal droplets. This micro system utilized silicon oil as the continuous phase and Ga66In20.5Sn13.5 (66.0 wt % Ga, 20.5 wt % In, 13.5 wt % Sn, melting point: 10.6 °C) as the dispersed phase to generate liquid metal droplets on a three-channel F-junction generator. The F-junction is an updated design similar to the classical T-junction, which has a special branch channel added to a T-junction for the supplement of 30 wt % aqueous NaOH solution. To perform active sorting of liquid metal droplets by dielectrophoresis (DEP), the micro system utilized liquid-metal-filled microchannels as noncontact electrodes to induce electrical fields through the droplet channel. The electrode channels were symmetrically located on both sides of the droplet channel in the same horizontal level. According to the results, the micro system can generate uniformly spherical liquid metal droplets, and control the flow direction of the liquid metal droplets. To better understand the control mechanism, a numerical simulation of the electrical field was performed in detail in this work.

18 January 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
XZXuyan Zhou
Xuyan Zhou
RZRenchang Zhang
Renchang Zhang
LLLuojia Li
Luojia Li
LZLunjia Zhang
Lunjia Zhang
BLBingxin Liu
Bingxin Liu
Lin GuiLin Gui
Lin Gui
A liquid-metal based capacitive soft pressure microsensor is proposed in this work for measuring pressure in microchannels. To measure the pressure of the target microchannel, a short detection channel is fabricated and connected to the target microchannel. Because the detection channel has only one outlet at the end which is connected to the target microchannel, the fluid in the detection channel will stay still during the measurement and the pressure remains constant inside the detection channel. A segment of reference fluid which is immiscible with the working fluid is sealed inside the detection channel. Because the chip material is soft, the pressure change will lead to the movement of the interface between the reference fluid and working fluid inside the detection channel. A pair of liquid metal electrodes are fabricated on both sides of the detection channel. By measuring the capacitance between these two liquid metal electrodes, the movement of the interface can be detected, and thus the pressure change can be detected as well. To minimize the influence from the environment, two liquid metal shield layers are placed on the top and the bottom of the microchannel layer separately. The microsensor was first tested in a microfluidic system and then utilized to measure the blood pressure of rabbit carotid artery in vivo. The experimental results showed excellent stability and linear correlation between capacitance and the value of fluid pressure. The pressure sensor can achieve a resolution of 7.5 mmHg within a pressure range of 20–300 mmHg. This work provides a promising approach to develop an implantable blood or intraocular pressure-monitoring device for clinical use.

6 June 2016 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
MGMeng Gao
Meng Gao
Lin GuiLin Gui
Lin Gui
Room temperature liquid metal gallium alloy has been widely used in many micro-electromechanical systems applications, such as on-chip electrical microheaters, micro temperature sensors, micro pumps and so on. Injecting liquid metal into microchannels can provide a simple, rapid, low-cost but efficient way to integrate these elements in microfluidic chips with high accuracy. The liquid metal-filled microstructures can be designed in any shape and easily integrated into microfluidic chips. In this paper, an on-chip liquid metal-based thermal microfluidic system is proposed for quick temperature control at the microscale. The micro system utilizes just one microfluidic chip as a basic working platform, which has liquid metal-based on-chip heaters, temperature sensors and electroosmotic flow pumps. Under the comprehensive control of these elements, the micro system can quickly change the temperature of a target fluid in the microfluidic chip. These liquid metal-based on-chip elements are very helpful for the fabrication and miniaturization of the microfluidic chip. In this paper, deionized water is used to test the temperature control performance of the thermal microfluidic system. According to the experimental results, the micro system can efficiently control the temperature of water ranging from 28 °C to 90 °C. The thermal microfluidic system has great potential for use in many microfluidic applications, such as on-chip polymerase chain reaction, temperature gradient focusing, protein crystallization and chemical synthesis.

14 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
QWQifu Wang
Qifu Wang
MGMeng Gao
Meng Gao
LZLunjia Zhang
Lunjia Zhang
ZDZhong-Shan Deng
Zhong-Shan Deng
Lin GuiLin Gui
Lin Gui
A handy, flexible micro-thermocouple using low-melting-point metal alloys is proposed in this paper. The thermocouple has the advantages of simple fabrication and convenient integration. Bismuth/gallium-based mixed alloys are used as thermocouple materials. To precisely inject the metal alloys to the location of the sensing area, a micro-polydimethylsiloxane post is designed within the sensing area to prevent outflow of the metal alloy to another thermocouple pole during the metal-alloy injection. Experimental results showed that the Seebeck coefficient of this thermocouple reached −10.54 μV/K, which was much higher than the previously reported 0.1 μV/K. The thermocouple was also be bent at 90° more than 200 times without any damage when the mass ratio of the bismuth-based alloy was <60% in the metal-alloy mixture. This technology mitigated the difficulty of depositing traditional thin–film thermocouples on soft substrates. Therefore, the thermocouple demonstrated its potential for use in microfluidic chips, which are usually flexible devices.