Nuria Barniol

Dr. Nuria Barniol

Departament d'Enginyeria Electrònica, Universitat Autònoma de Barcelona, Barcelona, Spain
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 1990 in Thin Solid Films
Verified
Journal Article
Closed access
Jordi SuñéJordi Suñé
Jordi Suñé
IPI. Placencia
I. Placencia
Nuria BarniolNuria Barniol
Nuria Barniol
EFE. Farrés
E. Farrés
Ferran MartinFerran Martin
Ferran Martin
XAX. Aymerich
X. Aymerich

21 January 2008 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
JVJ. Verd
J. Verd
AUArantxa Uranga
Arantxa Uranga
GAG. Abadal
G. Abadal
JTJ. L. Teva
J. L. Teva
FTFrancesc Torres
Francesc Torres
Nuria BarniolNuria Barniol
Nuria Barniol
This letter presents the design, fabrication, and demonstration of a CMOS/microelectromechanical system (MEMS) electrostatically self-excited resonator based on a submicrometer-scale cantilever with ~1 ag/Hz mass sensitivity. The mechanical resonator is the frequency-determining element of an oscillator circuit monolithically integrated and implemented in a commercial 0.35 mum CMOS process. The oscillator is based on a Pierce topology adapted for the MEMS resonator that presents a mechanical resonance frequency of ~6 MHz, a relative low quality factor of 100, and a large motional resistance of ~25 M. The MEMS oscillator has a frequency stability of ~1.6 Hz resulting in a mass resolution of ~1 ag (1 ag = 10-18 g in air conditions.

25 May 2001 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
GAG Abadal
G Abadal
ZDZ J Davis
Z J Davis
BHB Helbo
B Helbo
XBX Borrisé
X Borrisé
RRR Ruiz
R Ruiz
Nuria BarniolNuria Barniol
Nuria Barniol
A simple linear electromechanical model for an electrostatically driven resonating cantilever is derived. The model has been developed in order to determine dynamic quantities such as the capacitive current flowing through the cantilever-driver system at the resonance frequency, and it allows us to calculate static magnitudes such as position and voltage of collapse or the voltage versus deflection characteristic. The model is used to demonstrate the theoretical sensitivity on the attogram scale of a mass sensor based on a nanometre-scale cantilever, and to analyse the effect of an extra feedback loop in the control circuit to increase the Q factor.

21 July 2005 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
EFE. Forsen
E. Forsen
GAG. Abadal
G. Abadal
SGS. Ghatnekar-Nilsson
S. Ghatnekar-Nilsson
JTJ. Teva
J. Teva
JVJ. Verd
J. Verd
ABAnja Boisen
Anja Boisen
Nanomechanical resonators have been monolithically integrated on preprocessed complementary metal-oxide-semiconductor (CMOS) chips. Fabricated resonator systems have been designed to have resonance frequencies up to 1.5 MHz. The systems have been characterized in ambient air and vacuum conditions and display ultrasensitive mass detection in air. A mass sensitivity of 4ag∕Hz has been determined in air by placing a single glycerine drop, having a measured weight of 57 fg, at the apex of a cantilever and subsequently measuring a frequency shift of 14.8 kHz. CMOS integration enables electrostatic excitation, capacitive detection, and amplification of the resonance signal directly on the chip.

1 January 2015 in Microelectronic Engineering
Verified
Journal Article
Closed access
AUArantxa Uranga
Arantxa Uranga
JVJ. Verd
J. Verd
Nuria BarniolNuria Barniol
Nuria Barniol

1 December 1995 in Journal of Applied Physics
Verified
Journal Article
Open access
FPFrancesc Perez-Murano
Francesc Perez-Murano
GAG. Abadal
G. Abadal
Nuria BarniolNuria Barniol
Nuria Barniol
XAX. Aymerich
X. Aymerich
JSJ. Servat
J. Servat
FSF. Sanz
F. Sanz
The nanometer¿scale oxidation of Si(100) surfaces in air is performed with an atomic force microscope working in tapping mode. Applying a positive voltage to the sample with respect to the tip, two kinds of modifications are induced on the sample: grown silicon oxide mounds less than 5 nm high and mounds higher than 10 nm (which are assumed to be gold depositions). The threshold voltage necessary to produce the modification is studied as a function of the average tip¿to¿sample distance