Heart rate variability (HRV) represents one of the most promising markers of the autonomic nervous system (ANS) regulation. However, it requires the acquisition of the ECG signal in order to reliably detect the RR intervals, which is not always easily and comfortably available in personal health applications. Additionally, due to progress in single spot optical sensors, photoplethysmography (PPG) is an interesting alternative for heartbeat interval measurements, since it is a more convenient and a less intrusive measurement technique. Driven by the technological advances in such sensors, wrist-worn devices are becoming a commodity, and the interest in the assessment of HRV indexes from the PPG analysis (pulse rate variability - PRV) is rising. In this study, we investigate the hypothesis of using PRV features as surrogates for HRV indexes, in three different contexts: healthy subjects at rest, healthy subjects after physical exercise and subjects with cardiovascular diseases (CVD). Additionally, we also evaluate which are the characteristic points better suited for PRV analysis in these contexts, i.e. the PPG waveform characteristic points leading to the PRV features that present the best estimates of HRV (correlation and error analysis). The achieved results suggest that the PRV can be often used as an alternative for HRV analysis in healthy subjects, with significant correlations above 82%, for both time and frequency features. Contrarily, in the post-exercise and CVD subjects, time and (most importantly) frequency domain features shall be used with caution (mean correlations ranging from 68% to 88%).
1 December 2008 in 2008 19th International Conference on Pattern Recognition
Atrial fibrillation (AF) is an arrhythmia that can lead to several patient risks. This kind of arrhythmia affects mostly elderly people, in particular those who suffer from heart failure (one of the main causes of hospitalization). Thus, detection of AF becomes decisive in the prevention of cardiac threats. In this paper an algorithm for AF detection based on a novel algorithm architecture and feature extraction methods is proposed. The aforementioned architecture is based on the analysis of the three main physiological characteristics of AF: i) P wave absence ii) heart rate irregularity and iii) atrial activity (AA). Discriminative features are extracted using model-based statistic and frequency based approaches. Sensitivity and specificity results (respectively, 93.80% and 96.09% using the MIT-BIH AF database) show that the proposed algorithm is able to outperform state-of-the-art methods.
Monitoring of cardiovascular function on a beat-to-beat basis is fundamental for protecting patients in different settings including emergency medicine and interventional cardiology, but still faces technical challenges and several limitations. In the present study, we propose a new method for the extraction of cardiovascular performance surrogates from analysis of the photoplethysmographic (PPG) signal alone.We propose using a multi-Gaussian (MG) model consisting of five Gaussian functions to decompose the PPG pulses into its main physiological components. From the analysis of these components, we aim to extract estimators of the left ventricular ejection time, blood pressure and vascular tone changes. Using a multi-derivative analysis of the components related with the systolic ejection, we investigate which are the characteristic points that best define the left ventricular ejection time (LVET). Six LVET estimates were compared with the echocardiographic LVET in a database comprising 68 healthy and cardiovascular diseased volunteers. The best LVET estimate achieved a low absolute error (15.41 ± 13.66 ms), and a high correlation (ρ = 0.78) with the echocardiographic reference.To assess the potential use of the temporal and morphological characteristics of the proposed MG model components as surrogates for blood pressure and vascular tone, six parameters have been investigated: the stiffness index (SI), the T1_d and T1_2 (defined as the time span between the MG model forward and reflected waves), the reflection index (RI), the R1_d and the R1_2 (defined as their amplitude ratio). Their association to reference values of blood pressure and total peripheral resistance was investigated in 43 volunteers exhibiting hemodynamic instability. A good correlation was found between the majority of the extracted and reference parameters, with an exception to R1_2 (amplitude ratio between the main forward wave and the first reflection wave), which correlated low with all the reference parameters. The highest correlation ([Formula: see text] = 0.45) was found between T1_2 and the total peripheral resistance index (TPRI); while in the patients that experienced syncope, the highest agreement ([Formula: see text] = 0.57) was found between SI and systolic blood pressure (SBP) and mean blood pressure (MBP).In conclusion, the presented method for the extraction of surrogates of cardiovascular performance might improve patient monitoring and warrants further investigation.
The presence of motion artifacts in photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular parameters in continuous monitoring applications. In the current paper we present an algorithm for motion artifact detection based on the analysis of the variations in the time and the period domain characteristics of the PPG signal. The extracted features are ranked using a normalized mutual information feature selection algorithm and the best features are used in a support vector machine classification model to distinguish between clean and corrupted sections of the PPG signal. The proposed method has been tested in healthy and cardiovascular diseased volunteers, considering 11 different motion artifact sources. The results achieved by the current algorithm (sensitivity--SE: 84.3%, specificity--SP: 91.5% and accuracy--ACC: 88.5%) show that the current methodology is able to identify both corrupted and clean PPG sections with high accuracy in both healthy (ACC: 87.5%) and cardiovascular diseases (ACC: 89.5%) context.
An emergent research area in software engineering and software reliability is the use of wearable biosensors to monitor the cognitive state of software developers during software development tasks. The goal is to gather physiologic manifestations that can be linked to error-prone scenarios related to programmers’ cognitive states. In this paper we investigate whether electroencephalography (EEG) can be applied to accurately identify programmers’ cognitive load associated with the comprehension of code with different complexity levels. Therefore, a controlled experiment involving 26 programmers was carried. We found that features related to Theta, Alpha, and Beta brain waves have the highest discriminative power, allowing the identification of code lines and demanding higher mental effort. The EEG results reveal evidence of mental effort saturation as code complexity increases. Conversely, the classic software complexity metrics do not accurately represent the mental effort involved in code comprehension. Finally, EEG is proposed as a reference, in particular, the combination of EEG with eye tracking information allows for an accurate identification of code lines that correspond to peaks of cognitive load, providing a reference to help in the future evaluation of the space and time accuracy of programmers’ cognitive state monitored using wearable devices compatible with software development activities.
Systolic time intervals are highly correlated to fundamental cardiac functions. Several studies have shown that these measurements have significant diagnostic and prognostic value in heart failure condition and are adequate for long-term patient follow-up and disease management. In this paper, we investigate the feasibility of using heart sound (HS) to accurately measure the opening and closing moments of the aortic heart valve. These moments are crucial to define the main systolic timings of the heart cycle, i.e. pre-ejection period (PEP) and left ventricular ejection time (LVET). We introduce an algorithm for automatic extraction of PEP and LVET using HS and electrocardiogram. PEP is estimated with a Bayesian approach using the signal's instantaneous amplitude and patient-specific time intervals between atrio-ventricular valve closure and aortic valve opening. As for LVET, since the aortic valve closure corresponds to the start of the S2 HS component, we base LVET estimation on the detection of the S2 onset. A comparative assessment of the main systolic time intervals is performed using synchronous signal acquisitions of the current gold standard in cardiac time-interval measurement, i.e. echocardiography, and HS. The algorithms were evaluated on a healthy population, as well as on a group of subjects with different cardiovascular diseases (CVD). In the healthy group, from a set of 942 heartbeats, the proposed algorithm achieved 7.66 ± 5.92 ms absolute PEP estimation error. For LVET, the absolute estimation error was 11.39 ± 8.98 ms. For the CVD population, 404 beats were used, leading to 11.86 ± 8.30 and 17.51 ± 17.21 ms absolute PEP and LVET errors, respectively. The results achieved in this study suggest that HS can be used to accurately estimate LVET and PEP.