(1) Background: Patients with respiratory conditions typically exhibit adventitious respiratory sounds (ARS), such as wheezes and crackles. ARS events have variable duration. In this work we studied the influence of event duration on automatic ARS classification, namely, how the creation of the Other class (negative class) affected the classifiers’ performance. (2) Methods: We conducted a set of experiments where we varied the durations of the other events on three tasks: crackle vs. wheeze vs. other (3 Class); crackle vs. other (2 Class Crackles); and wheeze vs. other (2 Class Wheezes). Four classifiers (linear discriminant analysis, support vector machines, boosted trees, and convolutional neural networks) were evaluated on those tasks using an open access respiratory sound database. (3) Results: While on the 3 Class task with fixed durations, the best classifier achieved an accuracy of 96.9%, the same classifier reached an accuracy of 81.8% on the more realistic 3 Class task with variable durations. (4) Conclusion: These results demonstrate the importance of experimental design on the assessment of the performance of automatic ARS classification algorithms. Furthermore, they also indicate, unlike what is stated in the literature, that the automatic classification of ARS is not a solved problem, as the algorithms’ performance decreases substantially under complex evaluation scenarios.
A new unsupervised and low complexity method for detection of S1 and S2 components of heart sound without the ECG reference is described The most reliable and invariant feature applied in current state-of-the-art of unsupervised heart sound segmentation algorithms is implicitly or explicitly the S1-S2 interval regularity. However; this criterion is inherently prone to noise influence and does not appropriately tackle the heart sound segmentation of arrhythmic cases. A solution based upon a high frequency marker; which is extracted from heart sound using the fast wavelet decomposition, is proposed in order to estimate instantaneous heart rate. This marker is physiologically motivated by the accentuated pressure differences found across heart valves, both in native and prosthetic valves, which leads to distinct high frequency signatures of the valve closing sounds. The algorithm has been validated with heart sound samples collected from patients with mechanical and bio prosthetic heart valve implants in different locations, as well as with patients with native valves. This approach exhibits high sensitivity and specificity without being dependent on the valve type nor their implant position. Further more, it exhibits invariance with respect to normal sinus rhythm (NSR) arrhythmias and sound recording location
The Pulse Transit Time (PTT) is generally assumed to be a good surrogate measure to comfortably track blood pressure (BP) and blood pressure changes. This paper investigates PTT variations for healthy young subjects during a sequence of short-term physical exercises. PTT was measured by two different methodologies having different measurement accuracies as well as underlying assumptions: the total PTT from heart to fingertip and the difference of fingertip and earlobe PTTs. Small non consistent changes and very low correlation of both PTTs with systolic blood pressure (SBP) have been observed for the study population (-0.19 ± 0.45 and 0.22 ± 0.46). In conclusion, there might be a need for an improved measurement accuracy of the sensors and data processing techniques in use. The applicability of the Moens-Korteweg equation is also questionable for young people having flexible arteries. In this case, significant radius changes do occur in the large arteries during exercise, which might counteract a PTT decrease with the BP elevation. These radius effects are excluded from the Moens-Korteweg model.
Lung sounds acquired by stethoscopes are extensively used in diagnosing and differentiating respiratory diseases. Although an extensive know-how has been built to interpret these sounds and identify diseases associated with certain patterns, its effective use is limited to individual experience of practitioners. This user-dependency manifests itself as a factor impeding the digital transformation of this valuable diagnostic tool, which can improve patient outcomes by continuous long-term respiratory monitoring under real-life conditions. Particularly patients suffering from respiratory diseases with progressive nature, such as chronic obstructive pulmonary diseases, are expected to benefit from long-term monitoring. Recently, the COVID-19 pandemic has also shown the lack of respiratory monitoring systems which are ready to deploy in operational conditions while requiring minimal patient education. To address particularly the latter subject, in this article, we present a sound acquisition module which can be integrated into a dedicated garment; thus, minimizing the role of the patient for positioning the stethoscope and applying the appropriate pressure. We have implemented a diaphragm-less acousto-electric transducer by stacking a silicone rubber and a piezoelectric film to capture thoracic sounds with minimum attenuation. Furthermore, we benchmarked our device with an electronic stethoscope widely used in clinical practice to quantify its performance.