Heart rate variability (HRV) represents one of the most promising markers of the autonomic nervous system (ANS) regulation. However, it requires the acquisition of the ECG signal in order to reliably detect the RR intervals, which is not always easily and comfortably available in personal health applications. Additionally, due to progress in single spot optical sensors, photoplethysmography (PPG) is an interesting alternative for heartbeat interval measurements, since it is a more convenient and a less intrusive measurement technique. Driven by the technological advances in such sensors, wrist-worn devices are becoming a commodity, and the interest in the assessment of HRV indexes from the PPG analysis (pulse rate variability - PRV) is rising. In this study, we investigate the hypothesis of using PRV features as surrogates for HRV indexes, in three different contexts: healthy subjects at rest, healthy subjects after physical exercise and subjects with cardiovascular diseases (CVD). Additionally, we also evaluate which are the characteristic points better suited for PRV analysis in these contexts, i.e. the PPG waveform characteristic points leading to the PRV features that present the best estimates of HRV (correlation and error analysis). The achieved results suggest that the PRV can be often used as an alternative for HRV analysis in healthy subjects, with significant correlations above 82%, for both time and frequency features. Contrarily, in the post-exercise and CVD subjects, time and (most importantly) frequency domain features shall be used with caution (mean correlations ranging from 68% to 88%).

1 August 2006
Verified
Conference Paper
Closed access
Dinesh K. KumarDinesh K. Kumar
Dinesh K. Kumar
PCPaulo De Carvalho
Paulo De Carvalho
MAM. Antunes
M. Antunes
JHJorge Henriques
Jorge Henriques
LEL. Eugenio
L. Eugenio
JHJ. Habetha
J. Habetha
A new unsupervised and low complexity method for detection of S1 and S2 components of heart sound without the ECG reference is described The most reliable and invariant feature applied in current state-of-the-art of unsupervised heart sound segmentation algorithms is implicitly or explicitly the S1-S2 interval regularity. However; this criterion is inherently prone to noise influence and does not appropriately tackle the heart sound segmentation of arrhythmic cases. A solution based upon a high frequency marker; which is extracted from heart sound using the fast wavelet decomposition, is proposed in order to estimate instantaneous heart rate. This marker is physiologically motivated by the accentuated pressure differences found across heart valves, both in native and prosthetic valves, which leads to distinct high frequency signatures of the valve closing sounds. The algorithm has been validated with heart sound samples collected from patients with mechanical and bio prosthetic heart valve implants in different locations, as well as with patients with native valves. This approach exhibits high sensitivity and specificity without being dependent on the valve type nor their implant position. Further more, it exhibits invariance with respect to normal sinus rhythm (NSR) arrhythmias and sound recording location

1 December 2008 in 2008 19th International Conference on Pattern Recognition
Verified
Conference Paper
Closed access
RCRicardo Couceiro
Ricardo Couceiro
PCP. Carvalho
P. Carvalho
JHJorge Henriques
Jorge Henriques
MAM. Antunes
M. Antunes
MHM. Harris
M. Harris
JHJ. Habetha
J. Habetha
Atrial fibrillation (AF) is an arrhythmia that can lead to several patient risks. This kind of arrhythmia affects mostly elderly people, in particular those who suffer from heart failure (one of the main causes of hospitalization). Thus, detection of AF becomes decisive in the prevention of cardiac threats. In this paper an algorithm for AF detection based on a novel algorithm architecture and feature extraction methods is proposed. The aforementioned architecture is based on the analysis of the three main physiological characteristics of AF: i) P wave absence ii) heart rate irregularity and iii) atrial activity (AA). Discriminative features are extracted using model-based statistic and frequency based approaches. Sensitivity and specificity results (respectively, 93.80% and 96.09% using the MIT-BIH AF database) show that the proposed algorithm is able to outperform state-of-the-art methods.

3 August 2015 in Physiological Measurement
Verified
Journal Article
Closed access
RCRicardo Couceiro
Ricardo Couceiro
PCP Carvalho
P Carvalho
Rui Pedro PaivaRui Pedro Paiva
Rui Pedro Paiva
JHJorge Henriques
Jorge Henriques
IQI Quintal
I Quintal
CMC Meyer
C Meyer
Monitoring of cardiovascular function on a beat-to-beat basis is fundamental for protecting patients in different settings including emergency medicine and interventional cardiology, but still faces technical challenges and several limitations. In the present study, we propose a new method for the extraction of cardiovascular performance surrogates from analysis of the photoplethysmographic (PPG) signal alone.We propose using a multi-Gaussian (MG) model consisting of five Gaussian functions to decompose the PPG pulses into its main physiological components. From the analysis of these components, we aim to extract estimators of the left ventricular ejection time, blood pressure and vascular tone changes. Using a multi-derivative analysis of the components related with the systolic ejection, we investigate which are the characteristic points that best define the left ventricular ejection time (LVET). Six LVET estimates were compared with the echocardiographic LVET in a database comprising 68 healthy and cardiovascular diseased volunteers. The best LVET estimate achieved a low absolute error (15.41 ± 13.66 ms), and a high correlation (ρ = 0.78) with the echocardiographic reference.To assess the potential use of the temporal and morphological characteristics of the proposed MG model components as surrogates for blood pressure and vascular tone, six parameters have been investigated: the stiffness index (SI), the T1_d and T1_2 (defined as the time span between the MG model forward and reflected waves), the reflection index (RI), the R1_d and the R1_2 (defined as their amplitude ratio). Their association to reference values of blood pressure and total peripheral resistance was investigated in 43 volunteers exhibiting hemodynamic instability. A good correlation was found between the majority of the extracted and reference parameters, with an exception to R1_2 (amplitude ratio between the main forward wave and the first reflection wave), which correlated low with all the reference parameters. The highest correlation ([Formula: see text] = 0.45) was found between T1_2 and the total peripheral resistance index (TPRI); while in the patients that experienced syncope, the highest agreement ([Formula: see text] = 0.57) was found between SI and systolic blood pressure (SBP) and mean blood pressure (MBP).In conclusion, the presented method for the extraction of surrogates of cardiovascular performance might improve patient monitoring and warrants further investigation.

12 November 2014 in Physiological Measurement
Verified
Journal Article
Closed access
RCRicardo Couceiro
Ricardo Couceiro
PCP Carvalho
P Carvalho
Rui Pedro PaivaRui Pedro Paiva
Rui Pedro Paiva
JHJorge Henriques
Jorge Henriques
JMJ Muehlsteff
J Muehlsteff
The presence of motion artifacts in photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular parameters in continuous monitoring applications. In the current paper we present an algorithm for motion artifact detection based on the analysis of the variations in the time and the period domain characteristics of the PPG signal. The extracted features are ranked using a normalized mutual information feature selection algorithm and the best features are used in a support vector machine classification model to distinguish between clean and corrupted sections of the PPG signal. The proposed method has been tested in healthy and cardiovascular diseased volunteers, considering 11 different motion artifact sources. The results achieved by the current algorithm (sensitivity--SE: 84.3%, specificity--SP: 91.5% and accuracy--ACC: 88.5%) show that the current methodology is able to identify both corrupted and clean PPG sections with high accuracy in both healthy (ACC: 87.5%) and cardiovascular diseases (ACC: 89.5%) context.

8 April 2011 in Physiological Measurement
Verified
Journal Article
Closed access
Dinesh K. KumarDinesh K. Kumar
Dinesh K. Kumar
PCP Carvalho
P Carvalho
MAM Antunes
M Antunes
Rui Pedro PaivaRui Pedro Paiva
Rui Pedro Paiva
JHJorge Henriques
Jorge Henriques
Heart sound is a valuable biosignal for diagnosis of a large set of cardiac diseases. Ambient and physiological noise interference is one of the most usual and highly probable incidents during heart sound acquisition. It tends to change the morphological characteristics of heart sound that may carry important information for heart disease diagnosis. In this paper, we propose a new method applicable in real time to detect ambient and internal body noises manifested in heart sound during acquisition. The algorithm is developed on the basis of the periodic nature of heart sounds and physiologically inspired criteria. A small segment of uncontaminated heart sound exhibiting periodicity in time as well as in the time-frequency domain is first detected and applied as a reference signal in discriminating noise from the sound. The proposed technique has been tested with a database of heart sounds collected from 71 subjects with several types of heart disease inducing several noises during recording. The achieved average sensitivity and specificity are 95.88% and 97.56%, respectively.