Michael Utz

Mr. Michael Utz

Research & Development, B.Braun Aesculap AG, Tuttlingen, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
USU. Simon
U. Simon
PAPeter Augat
Peter Augat
MUMichael Utz
Michael Utz
LCL. Claes
L. Claes
A dynamic model was developed to simulate complex interactions of mechanical stability, revascularisation and tissue differentiation in secondary fracture healing. Unlike previous models, blood perfusion was included as a spatio-temporal state variable to simulate the revascularisation process. A 2D, axisymmetrical finite element model described fracture callus mechanics. Fuzzy logic rules described the following biological processes: angiogenesis, intramembranous ossification, chondrogenesis, cartilage calcification and endochondral ossification, all of which depended on local strain state and local blood perfusion. In order to evaluate how the predicted revascularisation depended on the mechanical environment, we simulated two different healing cases according to two groups of transverse metatarsal osteotomies in sheep with different axial stability. The model predicted slower revascularisation and delayed bony bridging for the less stable case, which corresponded well to the experimental observations. A revascularisation sensitivity analysis demonstrated the potential of the model to account for different conditions regarding the blood supply.

28 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
JWJana Gerda Weber
Jana Gerda Weber
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
ASAdrian Sauer
Adrian Sauer
IDingrid dupraz
ingrid dupraz
MUMichael Utz
Michael Utz
TGThomas M. Grupp
Thomas M. Grupp
The use of inertial measurement units (IMUs) as an alternative to optical marker-based systems has the potential to make gait analysis part of the clinical standard of care. Previously, an IMU-based system leveraging Rauch–Tung–Striebel smoothing to estimate knee angles was assessed using a six-degrees-of-freedom joint simulator. In a clinical setting, however, accurately measuring abduction/adduction and external/internal rotation of the knee joint is particularly challenging, especially in the presence of soft tissue artefacts. In this study, the in vivo IMU-based joint angles of 40 asymptomatic knees were assessed during level walking, under two distinct sensor placement configurations: (1) IMUs fixed to a rigid harness, and (2) IMUs mounted on the skin using elastic hook-and-loop bands (from here on referred to as “skin-mounted IMUs”). Estimates were compared against values obtained from a harness-mounted optical marker-based system. The comparison of these three sets of kinematic signals (IMUs on harness, IMUs on skin, and optical markers on harness) was performed before and after implementation of a REference FRame Alignment MEthod (REFRAME) to account for the effects of differences in coordinate system orientations. Prior to the implementation of REFRAME, in comparison to optical estimates, skin-mounted IMU-based angles displayed mean root-mean-square errors (RMSEs) up to 6.5°, while mean RMSEs for angles based on harness-mounted IMUs peaked at 5.1°. After REFRAME implementation, peak mean RMSEs were reduced to 4.1°, and 1.5°, respectively. The negligible differences between harness-mounted IMUs and the optical system after REFRAME revealed that the IMU-based system was capable of capturing the same underlying motion pattern as the optical reference. In contrast, obvious differences between the skin-mounted IMUs and the optical reference indicated that the use of a harness led to fundamentally different joint motion being measured, even after accounting for reference frame misalignments. Fluctuations in the kinematic signals associated with harness use suggested the rigid device oscillated upon heel strike, likely due to inertial effects from its additional mass. Our study proposes that optical systems can be successfully replaced by more cost-effective IMUs with similar accuracy, but further investigation (especially in vivo and upon heel strike) against moving videofluoroscopy is recommended.

19 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IDingrid dupraz
ingrid dupraz
ABArthur Bollinger
Arthur Bollinger
JDJulien Deckx
Julien Deckx
RSRonja Alissa Schierjott
Ronja Alissa Schierjott
MUMichael Utz
Michael Utz
MJMarnic Jacobs
Marnic Jacobs
(1) TKA implants should well fit on each patient’s anatomy. Statistical Shape Models (SSM) statistically represent the anatomy of a given population. The aims of this study were to assess how to generate a valid SSM for implant design and provide guidelines and examples on how to use the SSMs to evaluate the anatomic fit of TKA components. (2) Methods: A Caucasian SSM was built from 120 anatomies (65 female, 55 male) and an Asian SSM was based on 112 patients (75 female, 37 male). These SSMs were used to generate a database of 20 bone models. The AP/ML dimensions of the bone models were compared to those of the input population. Design input parameters, such as the tibial contour, trochlea, and femur curvature were extracted from the SSMs. Femur and patella components were virtually implanted on the bone models. (3) Results: the dimensions of the generated bone models well represented the population. The overhang of the femoral component as well as the coverage and peak restoration of the patella component were visualized. (4) Conclusions: SSMs can be used to efficiently gain input into TKA design and evaluate the implant fit on the studied population.

5 September 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AEAnn-Kathrin Einfeldt
Ann-Kathrin Einfeldt
LBLeon Budde
Leon Budde
AOAriana Ortigas-Vásquez
Ariana Ortigas-Vásquez
ASAdrian Sauer
Adrian Sauer
MUMichael Utz
Michael Utz
Eike JakubowitzEike Jakubowitz
Eike Jakubowitz
The use of marker-based optical motion capture to estimate joint kinematics during gait is currently limited by errors associated with soft-tissue-induced motion artefacts (STIMA) and ambiguity in landmark palpation. This study therefore presents a novel protocol aiming to Minimize Knee Soft-Tissue Artefacts (MiKneeSoTA) and their effect on kinematic estimates. Relying on an augmented marker set and a new inverse kinematics approach, our method leverages frame-by-frame optimization to adjust best-fit cylinders that have been automatically generated based on the relative position of lower limb markers during an initial static trial. Tibiofemoral rotations and translations are then calculated along the anatomical joint axes based on the relative 3D motion of these cylinders. When compared against the conventional Helen-Hayes approach, in vivo assessment of fifteen healthy subjects revealed the MiKneeSoTA approach led to kinematic profiles with significantly lower standard deviations in joint rotations across trials, and even visibly reduced the presence of high frequency fluctuations presumably associated with e.g. soft-tissue vibration. In addition to agreeing with previously published bone pin and fluoroscopy datasets, our results illustrate MiKneeSoTA’s ability to abate the effect of STIMA induced by lateral knee ligaments. Our findings indicate that MiKneeSoTA is in fact a promising approach to mitigate knee joint STIMA and thus enable the previously unattainable accurate estimation of translational knee joint motion with an optoelectronic system.

1 September 2020 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MWMichael Wehmöller
Michael Wehmöller
MUMichael Utz
Michael Utz
VGValentine Gesche
Valentine Gesche
The Medical Technology Advisory Committee of the VDI Society develops a guideline for the implementation of digital process chains for patient-specific medical devices. The underlying medical device constitutes the basis for each individualized medical device. It serves as the development framework for manufacturing.

2 July 2016 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
SMSamuel Mueller
Samuel Mueller
IAIntsar Ahmad
Intsar Ahmad
MKManuel Kraemer
Manuel Kraemer
MUMichael Utz
Michael Utz
JGJohannes Gaa
Johannes Gaa
TOTobias Ortmaier
Tobias Ortmaier
Patient-specific instruments (PSIs) are clinically used to support the surgeon during a planned intervention. The planning is typically done based on volumetric image data from medical imaging systems, e.g. computed tomography (CT). The PSI uses the known surface structure of a bone for orientation during the intervention. Some surfaces of human bone are covered with a layer of cartilage which is hardly visible in clinically applied CT-imaging. This experimental study investigates ten different PSI designs and their effect to the overall accuracy when neglecting the cartilage in the design process. Therefore, a model of an acetabulum is used to simulate the use case of PSI in total hip arthroplasty. The concept of the different designs is to create structural elasticities in the PSI to avoid shifting of the whole instrument and rather have a small part of it deformed by cartilage. A needle array structure, for instance, should also be able to oust or penetrate remaining soft tissue in the acetabulum.