The use of inertial measurement units (IMUs) as an alternative to optical marker-based systems has the potential to make gait analysis part of the clinical standard of care. Previously, an IMU-based system leveraging Rauch–Tung–Striebel smoothing to estimate knee angles was assessed using a six-degrees-of-freedom joint simulator. In a clinical setting, however, accurately measuring abduction/adduction and external/internal rotation of the knee joint is particularly challenging, especially in the presence of soft tissue artefacts. In this study, the in vivo IMU-based joint angles of 40 asymptomatic knees were assessed during level walking, under two distinct sensor placement configurations: (1) IMUs fixed to a rigid harness, and (2) IMUs mounted on the skin using elastic hook-and-loop bands (from here on referred to as “skin-mounted IMUs”). Estimates were compared against values obtained from a harness-mounted optical marker-based system. The comparison of these three sets of kinematic signals (IMUs on harness, IMUs on skin, and optical markers on harness) was performed before and after implementation of a REference FRame Alignment MEthod (REFRAME) to account for the effects of differences in coordinate system orientations. Prior to the implementation of REFRAME, in comparison to optical estimates, skin-mounted IMU-based angles displayed mean root-mean-square errors (RMSEs) up to 6.5°, while mean RMSEs for angles based on harness-mounted IMUs peaked at 5.1°. After REFRAME implementation, peak mean RMSEs were reduced to 4.1°, and 1.5°, respectively. The negligible differences between harness-mounted IMUs and the optical system after REFRAME revealed that the IMU-based system was capable of capturing the same underlying motion pattern as the optical reference. In contrast, obvious differences between the skin-mounted IMUs and the optical reference indicated that the use of a harness led to fundamentally different joint motion being measured, even after accounting for reference frame misalignments. Fluctuations in the kinematic signals associated with harness use suggested the rigid device oscillated upon heel strike, likely due to inertial effects from its additional mass. Our study proposes that optical systems can be successfully replaced by more cost-effective IMUs with similar accuracy, but further investigation (especially in vivo and upon heel strike) against moving videofluoroscopy is recommended.
A correlation between patellar kinematics and anterior knee pain is widely accepted. However, there is no consensus on how they are connected or what profile of patellar kinematics would minimize anterior knee pain. Nevertheless, answering this question by merging existing studies is further complicated by the variety of ways to describe patellar kinematics. Therefore, this study describes the most frequently used conventions for defining patellar kinematics, focusing on the rotations. The similarities and differences between the Cardan sequences and angles calculated by projecting axes are analyzed. Additionally, a tool is provided to enable the conversion of kinematic data between definitions in different studies. The choice of convention has a considerable impact on the absolute values and the clinical characteristics of the patello-femoral angles. In fact, the angles that result from using different mathematical conventions to describe a given patello-femoral rotation from our analyses differ up to a Root Mean Squared Error of 111.49° for patellar flexion, 55.72° for patellar spin and 35.39° for patellar tilt. To compare clinical kinematic patello-femoral results, every dataset must follow the same convention. Furthermore, researchers should be aware of the used convention’s implications to ensure reproducibility when interpreting and comparing such data.
The isolated effects of patellar resurfacing on patellar kinematics are rarely investigated. Nonetheless, knowing more about these effects could help to enhance present understanding of the emergence of kinematic improvements or deteriorations associated with patellar resurfacing. The aim of this study was to isolate the effects of patellar resurfacing from a multi-stage in vitro study, where kinematics after total knee arthroplasty before and after patellar resurfacing were recorded. Additionally, the influence of the native patellar geometry on these effects was analysed. Eight fresh frozen specimens were tested successively with different implant configurations on an already established weight bearing knee rig. The patello-femoral kinematics were thereby measured using an ultrasonic measurement system and its relation to the native patellar geometries was analysed. After patellar resurfacing, the specimen showed a significantly medialized patellar shift. This medialization of the patellar tracking was significantly correlated to the lateral facet angle of the native patella. The patellar shift after patellar resurfacing is highly influenced by the position of the patellar button and the native lateral patellar facet angle. As a result, the ideal medio-lateral position of the patellar component is affected by the geometry of the native patella.
In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by a lack of consensus around joint coordinate frame definitions, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation. Consequently, for consistent interpretation of joint motion (especially direct comparison) to be possible, differences in local frame position and orientation must first be addressed. Here, building on previous work that introduced a frame orientation optimisation method and demonstrated its potential to induce convergence towards a consistent kinematic signal, we present the REference FRame Alignment MEthod (REFRAME) that addresses both rotational and translational kinematics, is validated here for a healthy tibiofemoral joint, and allows flexible selection of optimisation criteria to fittingly address specific research questions. While not claiming to improve the accuracy of joint kinematics or reference frame axes, REFRAME does enable a representation of knee kinematic signals that accounts for differences in local frames (regardless of how these differences were introduced, e.g. anatomical heterogeneity, use of different data capture modalities or joint axis approaches, intra- and inter-rater reliability, etc.), as evidenced by peak root-mean-square errors of 0.24° ± 0.17° and 0.03 mm ± 0.01 mm after its implementation. By using a self-contained optimisation approach to systematically re-align the position and orientation of reference frames, REFRAME allows researchers to better assess whether two kinematic signals represent fundamentally similar or different underlying knee motion. The openly available implementation of REFRAME could therefore allow the consistent interpretation and comparison of knee kinematic signals across trials, subjects, examiners, or even research institutes.
Recently, inertial measurement units have been gaining popularity as a potential alternative to optical motion capture systems in the analysis of joint kinematics. In a previous study, the accuracy of knee joint angles calculated from inertial data and an extended Kalman filter and smoother algorithm was tested using ground truth data originating from a joint simulator guided by fluoroscopy-based signals. Although high levels of accuracy were achieved, the experimental setup leveraged multiple iterations of the same movement pattern and an absence of soft tissue artefacts. Here, the algorithm is tested against an optical marker-based system in a more challenging setting, with single iterations of a loaded squat cycle simulated on seven cadaveric specimens on a force-controlled knee rig. Prior to the optimisation of local coordinate systems using the REference FRame Alignment MEthod (REFRAME) to account for the effect of differences in local reference frame orientation, root-mean-square errors between the kinematic signals of the inertial and optical systems were as high as 3.8° ± 3.5° for flexion/extension, 20.4° ± 10.0° for abduction/adduction and 8.6° ± 5.7° for external/internal rotation. After REFRAME implementation, however, average root-mean-square errors decreased to 0.9° ± 0.4° and to 1.5° ± 0.7° for abduction/adduction and for external/internal rotation, respectively, with a slight increase to 4.2° ± 3.6° for flexion/extension. While these results demonstrate promising potential in the approach’s ability to estimate knee joint angles during a single loaded squat cycle, they highlight the limiting effects that a reduced number of iterations and the lack of a reliable consistent reference pose inflicts on the sensor fusion algorithm’s performance. They similarly stress the importance of adapting underlying assumptions and correctly tuning filter parameters to ensure satisfactory performance. More importantly, our findings emphasise the notable impact that properly aligning reference-frame orientations before comparing joint kinematics can have on results and the conclusions derived from them.
Although simulation models are heavily used in biomechanical research and testing of TKA implants, pre-clinical tools for a holistic estimation of implant performance under dynamic loading conditions are rare. The objective of this study was the development of an efficient pre-clinical test method for analyzing knee contact mechanics and kinematics based on a dynamic FE model and to evaluate the effects of the proximo-distal patella position and the patellar tendon stiffness on the patellar kinematics. A finite element-based workflow for knee prostheses designs was developed based on standardized in vivo load data, which included the tibial forces and moments. In a new research approach, the tibial forces are used as input for the model, whereas the tibial moments were used to validate the results. For the standardized sit down, stand up, and knee bend load cycles, the calculated tibial moments show only small deviations from the reference values—especially for high flexion angles. For the knee bend cycle, the maximum absolute value of patellar flexion decreases for higher patellar tendon stiffness and more distally placed patellar components. Therefore, patella-related clinical problems caused by patella baja may also arise if the patellar tendon is too weak for high tibiofemoral flexion angles.