Ariana Ortigas Vásquez

Ms. Ariana Ortigas Vásquez

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
JWJana Gerda Weber
Jana Gerda Weber
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
ASAdrian Sauer
Adrian Sauer
IDingrid dupraz
ingrid dupraz
MUMichael Utz
Michael Utz
TGThomas M. Grupp
Thomas M. Grupp
The use of inertial measurement units (IMUs) as an alternative to optical marker-based systems has the potential to make gait analysis part of the clinical standard of care. Previously, an IMU-based system leveraging Rauch–Tung–Striebel smoothing to estimate knee angles was assessed using a six-degrees-of-freedom joint simulator. In a clinical setting, however, accurately measuring abduction/adduction and external/internal rotation of the knee joint is particularly challenging, especially in the presence of soft tissue artefacts. In this study, the in vivo IMU-based joint angles of 40 asymptomatic knees were assessed during level walking, under two distinct sensor placement configurations: (1) IMUs fixed to a rigid harness, and (2) IMUs mounted on the skin using elastic hook-and-loop bands (from here on referred to as “skin-mounted IMUs”). Estimates were compared against values obtained from a harness-mounted optical marker-based system. The comparison of these three sets of kinematic signals (IMUs on harness, IMUs on skin, and optical markers on harness) was performed before and after implementation of a REference FRame Alignment MEthod (REFRAME) to account for the effects of differences in coordinate system orientations. Prior to the implementation of REFRAME, in comparison to optical estimates, skin-mounted IMU-based angles displayed mean root-mean-square errors (RMSEs) up to 6.5°, while mean RMSEs for angles based on harness-mounted IMUs peaked at 5.1°. After REFRAME implementation, peak mean RMSEs were reduced to 4.1°, and 1.5°, respectively. The negligible differences between harness-mounted IMUs and the optical system after REFRAME revealed that the IMU-based system was capable of capturing the same underlying motion pattern as the optical reference. In contrast, obvious differences between the skin-mounted IMUs and the optical reference indicated that the use of a harness led to fundamentally different joint motion being measured, even after accounting for reference frame misalignments. Fluctuations in the kinematic signals associated with harness use suggested the rigid device oscillated upon heel strike, likely due to inertial effects from its additional mass. Our study proposes that optical systems can be successfully replaced by more cost-effective IMUs with similar accuracy, but further investigation (especially in vivo and upon heel strike) against moving videofluoroscopy is recommended.

14 June 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
William R. TaylorWilliam R. Taylor
William R. Taylor
AMAllan Maas
Allan Maas
MWMatthias Woiczinski
Matthias Woiczinski
TGThomas M. Grupp
Thomas M. Grupp
ASAdrian Sauer
Adrian Sauer
In clinical movement biomechanics, kinematic data are often depicted as waveforms (i.e. signals), characterising the motion of articulating joints. Clinically meaningful interpretations of the underlying joint kinematics, however, require an objective understanding of whether two different kinematic signals actually represent two different underlying physical movement patterns of the joint or not. Previously, the accuracy of IMU-based knee joint angles was assessed using a six-degrees-of-freedom joint simulator guided by fluoroscopy-based signals. Despite implementation of sensor-to-segment corrections, observed errors were clearly indicative of cross-talk, and thus inconsistent reference frame orientations. Here, we address these limitations by exploring how minimisation of dedicated cost functions can harmonise differences in frame orientations, ultimately facilitating consistent interpretation of articulating joint kinematic signals. In this study, we present and investigate a frame orientation optimisation method (FOOM) that aligns reference frames and corrects for cross-talk errors, hence yielding a consistent interpretation of the underlying movement patterns. By executing optimised rotational sequences, thus producing angular corrections around each axis, we enable a reproducible frame definition and hence an approach for reliable comparison of kinematic data. Using this approach, root-mean-square errors between the previously collected (1) IMU-based data using functional joint axes, and (2) simulated fluoroscopy-based data relying on geometrical axes were almost entirely eliminated from an initial range of 0.7°–5.1° to a mere 0.1°–0.8°. Our results confirm that different local segment frames can yield different kinematic patterns, despite following the same rotation convention, and that appropriate alignment of reference frame orientation can successfully enable consistent kinematic interpretation.

29 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
AMAllan Maas
Allan Maas
RLRenate List
Renate List
PSPascal Schütz
Pascal Schütz
William R. TaylorWilliam R. Taylor
William R. Taylor
TGThomas M. Grupp
Thomas M. Grupp
The success of kinematic analysis that relies on inertial measurement units (IMUs) heavily depends on the performance of the underlying algorithms. Quantifying the level of uncertainty associated with the models and approximations implemented within these algorithms, without the complication of soft-tissue artefact, is therefore critical. To this end, this study aimed to assess the rotational errors associated with controlled movements. Here, data of six total knee arthroplasty patients from a previously published fluoroscopy study were used to simulate realistic kinematics of daily activities using IMUs mounted to a six-degrees-of-freedom joint simulator. A model-based method involving extended Kalman filtering to derive rotational kinematics from inertial measurements was tested and compared against the ground truth simulator values. The algorithm demonstrated excellent accuracy (root-mean-square error ≤0.9°, maximum absolute error ≤3.2°) in estimating three-dimensional rotational knee kinematics during level walking. Although maximum absolute errors linked to stair descent and sit-to-stand-to-sit rose to 5.2° and 10.8°, respectively, root-mean-square errors peaked at 1.9° and 7.5°. This study hereby describes an accurate framework for evaluating the suitability of the underlying kinematic models and assumptions of an IMU-based motion analysis system, facilitating the future validation of analogous tools.

17 January 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
William R. TaylorWilliam R. Taylor
William R. Taylor
BPBarbara Postolka
Barbara Postolka
PSPascal Schütz
Pascal Schütz
AMAllan Maas
Allan Maas
ASAdrian Sauer
Adrian Sauer
In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation. Consequently, for consistent interpretation of joint motion (especially direct comparison) to be possible, differences in local frame position and orientation must first be addressed. Here, building on previous work that introduced a frame orientation optimisation method and demonstrated its potential to induce convergence towards a consistent kinematic signal, we present the REference FRame Alignment MEthod (REFRAME) that addresses both rotational and translational kinematics, is validated here for a healthy tibiofemoral joint, and allows flexible selection of optimisation criteria to fittingly address specific research questions. While not claiming to improve the accuracy of joint kinematics or reference frame axes, REFRAME does enable a representation of knee kinematic signals that accounts for differences in local frames (regardless of how these differences were introduced, e.g. anatomical heterogeneity, use of different data capture modalities or joint axis approaches, intra- and inter-rater reliability, etc.), as evidenced by peak root-mean-square errors of 0.24° ± 0.17° and 0.03 mm ± 0.01 mm after its implementation. By using a self-contained optimisation approach to systematically re-align the position and orientation of reference frames, REFRAME allows researchers to better assess whether two kinematic signals represent fundamentally similar or different underlying knee motion. The openly available implementation of REFRAME could therefore allow the consistent interpretation and comparison of knee kinematic signals across trials, subjects, examiners, or even research institutes.

5 April 2024 in Research Square
Verified
Preprint
Open access
PDF file
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
William R. TaylorWilliam R. Taylor
William R. Taylor
BPBarbara Postolka
Barbara Postolka
PSPascal Schütz
Pascal Schütz
AMAllan Maas
Allan Maas
ASAdrian Sauer
Adrian Sauer
In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by a lack of consensus around joint coordinate frame definitions, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation. Consequently, for consistent interpretation of joint motion (especially direct comparison) to be possible, differences in local frame position and orientation must first be addressed. Here, building on previous work that introduced a frame orientation optimisation method and demonstrated its potential to induce convergence towards a consistent kinematic signal, we present the REference FRame Alignment MEthod (REFRAME) that addresses both rotational and translational kinematics, is validated here for a healthy tibiofemoral joint, and allows flexible selection of optimisation criteria to fittingly address specific research questions. While not claiming to improve the accuracy of joint kinematics or reference frame axes, REFRAME does enable a representation of knee kinematic signals that accounts for differences in local frames (regardless of how these differences were introduced, e.g. anatomical heterogeneity, use of different data capture modalities or joint axis approaches, intra- and inter-rater reliability, etc.), as evidenced by peak root-mean-square errors of 0.24° ± 0.17° and 0.03 mm ± 0.01 mm after its implementation. By using a self-contained optimisation approach to systematically re-align the position and orientation of reference frames, REFRAME allows researchers to better assess whether two kinematic signals represent fundamentally similar or different underlying knee motion. The openly available implementation of REFRAME could therefore allow the consistent interpretation and comparison of knee kinematic signals across trials, subjects, examiners, or even research institutes.

23 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SSSvenja Sagasser
Svenja Sagasser
ASAdrian Sauer
Adrian Sauer
CTChristoph Thorwächter
Christoph Thorwächter
JWJana Gerda Weber
Jana Gerda Weber
AMAllan Maas
Allan Maas
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
Recently, inertial measurement units have been gaining popularity as a potential alternative to optical motion capture systems in the analysis of joint kinematics. In a previous study, the accuracy of knee joint angles calculated from inertial data and an extended Kalman filter and smoother algorithm was tested using ground truth data originating from a joint simulator guided by fluoroscopy-based signals. Although high levels of accuracy were achieved, the experimental setup leveraged multiple iterations of the same movement pattern and an absence of soft tissue artefacts. Here, the algorithm is tested against an optical marker-based system in a more challenging setting, with single iterations of a loaded squat cycle simulated on seven cadaveric specimens on a force-controlled knee rig. Prior to the optimisation of local coordinate systems using the REference FRame Alignment MEthod (REFRAME) to account for the effect of differences in local reference frame orientation, root-mean-square errors between the kinematic signals of the inertial and optical systems were as high as 3.8° ± 3.5° for flexion/extension, 20.4° ± 10.0° for abduction/adduction and 8.6° ± 5.7° for external/internal rotation. After REFRAME implementation, however, average root-mean-square errors decreased to 0.9° ± 0.4° and to 1.5° ± 0.7° for abduction/adduction and for external/internal rotation, respectively, with a slight increase to 4.2° ± 3.6° for flexion/extension. While these results demonstrate promising potential in the approach’s ability to estimate knee joint angles during a single loaded squat cycle, they highlight the limiting effects that a reduced number of iterations and the lack of a reliable consistent reference pose inflicts on the sensor fusion algorithm’s performance. They similarly stress the importance of adapting underlying assumptions and correctly tuning filter parameters to ensure satisfactory performance. More importantly, our findings emphasise the notable impact that properly aligning reference-frame orientations before comparing joint kinematics can have on results and the conclusions derived from them.