ingrid dupraz

Dr. ingrid dupraz


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
JWJana Gerda Weber
Jana Gerda Weber
AVAriana Ortigas Vásquez
Ariana Ortigas Vásquez
ASAdrian Sauer
Adrian Sauer
IDingrid dupraz
ingrid dupraz
MUMichael Utz
Michael Utz
TGThomas M. Grupp
Thomas M. Grupp
The use of inertial measurement units (IMUs) as an alternative to optical marker-based systems has the potential to make gait analysis part of the clinical standard of care. Previously, an IMU-based system leveraging Rauch–Tung–Striebel smoothing to estimate knee angles was assessed using a six-degrees-of-freedom joint simulator. In a clinical setting, however, accurately measuring abduction/adduction and external/internal rotation of the knee joint is particularly challenging, especially in the presence of soft tissue artefacts. In this study, the in vivo IMU-based joint angles of 40 asymptomatic knees were assessed during level walking, under two distinct sensor placement configurations: (1) IMUs fixed to a rigid harness, and (2) IMUs mounted on the skin using elastic hook-and-loop bands (from here on referred to as “skin-mounted IMUs”). Estimates were compared against values obtained from a harness-mounted optical marker-based system. The comparison of these three sets of kinematic signals (IMUs on harness, IMUs on skin, and optical markers on harness) was performed before and after implementation of a REference FRame Alignment MEthod (REFRAME) to account for the effects of differences in coordinate system orientations. Prior to the implementation of REFRAME, in comparison to optical estimates, skin-mounted IMU-based angles displayed mean root-mean-square errors (RMSEs) up to 6.5°, while mean RMSEs for angles based on harness-mounted IMUs peaked at 5.1°. After REFRAME implementation, peak mean RMSEs were reduced to 4.1°, and 1.5°, respectively. The negligible differences between harness-mounted IMUs and the optical system after REFRAME revealed that the IMU-based system was capable of capturing the same underlying motion pattern as the optical reference. In contrast, obvious differences between the skin-mounted IMUs and the optical reference indicated that the use of a harness led to fundamentally different joint motion being measured, even after accounting for reference frame misalignments. Fluctuations in the kinematic signals associated with harness use suggested the rigid device oscillated upon heel strike, likely due to inertial effects from its additional mass. Our study proposes that optical systems can be successfully replaced by more cost-effective IMUs with similar accuracy, but further investigation (especially in vivo and upon heel strike) against moving videofluoroscopy is recommended.

19 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IDingrid dupraz
ingrid dupraz
ABArthur Bollinger
Arthur Bollinger
JDJulien Deckx
Julien Deckx
RSRonja Alissa Schierjott
Ronja Alissa Schierjott
MUMichael Utz
Michael Utz
MJMarnic Jacobs
Marnic Jacobs
(1) TKA implants should well fit on each patient’s anatomy. Statistical Shape Models (SSM) statistically represent the anatomy of a given population. The aims of this study were to assess how to generate a valid SSM for implant design and provide guidelines and examples on how to use the SSMs to evaluate the anatomic fit of TKA components. (2) Methods: A Caucasian SSM was built from 120 anatomies (65 female, 55 male) and an Asian SSM was based on 112 patients (75 female, 37 male). These SSMs were used to generate a database of 20 bone models. The AP/ML dimensions of the bone models were compared to those of the input population. Design input parameters, such as the tibial contour, trochlea, and femur curvature were extracted from the SSMs. Femur and patella components were virtually implanted on the bone models. (3) Results: the dimensions of the generated bone models well represented the population. The overhang of the femoral component as well as the coverage and peak restoration of the patella component were visualized. (4) Conclusions: SSMs can be used to efficiently gain input into TKA design and evaluate the implant fit on the studied population.

22 May 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
IDingrid dupraz
ingrid dupraz
CTChristoph Thorwächter
Christoph Thorwächter
TGThomas M. Grupp
Thomas M. Grupp
FHFlorian Hammerschmid
Florian Hammerschmid
MWMatthias Woiczinski
Matthias Woiczinski
ASArnd Steinbrück
Arnd Steinbrück

1 January 2012 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Open access
PDF file
ODOlaf Dössel
Olaf Dössel
PAPeter Augat
Peter Augat
PBPeter Boesiger
Peter Boesiger
HZH.-F Zurich
H.-F Zurich
HGHermann Gehring
Hermann Gehring
Mahmoud A HafezMahmoud A Hafez
Mahmoud A Hafez

31 July 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
IDingrid dupraz
ingrid dupraz
YMYukihide Minoda
Yukihide Minoda
NKNikolai Kornilov
Nikolai Kornilov
BABrigitte Altermann
Brigitte Altermann
PHPhilipp Hauff
Philipp Hauff
TGThomas M. Grupp
Thomas M. Grupp
Introduction and aim: Modern tibial implants should be designed to achieve an optimal anatomical fit. The aim of this study was to evaluate how well a newly developed tibial implant design (oneKNEE ® – B. Braun Aesculap, Tuttlingen, Germany) matches patient anatomy compared to three existing implant systems, using Statistical Shape Models (SSM). Method: SSMs for Caucasian and Asian populations were generated using CT scans of 120 Caucasian and 112 Asian osteoarthritic patients. Border anatomical variations were represented by individual anatomies from 14 Caucasian and 12 Asian patients. Tibial components were positioned in accordance with strict protocols established by senior knee surgeons (YM, NK). The anatomical fit was analyzed across all four implant systems in terms of antero-posterior and medio-lateral dimensions, tibial coverage and cortical bone support. Global tests for homogeneity and Dunnett’s tests were performed. Results: Bony coverage for Asian and Caucasian populations ranged from 82.9% to 88.4% for long-established designs and from 85.0% to 91.2% for more recently introduced designs. Among all designs, the oneKNEE ® implant demonstrated superior bony coverage and cortical support, followed by Attune ® (Depuy-Synthes, Warsaw, IN, USA), Columbus ® (B. Braun Aesculap), and PFC Sigma ® (Depuy-Synthes). For average anatomies, oneKNEE ® showed significantly better bony coverage and cortical score compared to Columbus ® and PFC Sigma ® (P < 0.01). In less average anatomies, oneKNEE ® exhibited statistically superior bony coverage compared to PFC Sigma ® , although no significant difference was observed in cortical support. Conclusion: Compared with established tibial implant designs, the new design demonstrated improved virtual anatomical fit and coverage metrics based on computational modeling. These findings reflect a theoretical design‑level improvement and require biomechanical and clinical validation.