Alpha-decay propulsion technology, a microthrust technology based on thin spontaneous-alpha-decay films, is proposed in this paper. A large quantity of decayed alpha particles emitted from the upper surface of thin films would generate thrust statistically. Simulations were executed using the Monte Carlo N-Particle Transport Code (MCNP) to acquire the energy and angular distributions of escaping alpha particles, as well as the key parameters of alpha-decay films. A 22.40-μm 210Po film combined with a 20-μm aluminum film was able to generate an average thrust of 29.5 nN/cm2 in half-life time. The remaining charges and thermal energies of the decay films were considered. Directional-generated alpha particles were simulated to analyze the influence of angular scattering on escaped alpha-particle distributions. Alpha particles with low energy, with large scattering angles, or with large generated angles contributed less to thrust value. With the assumptions of no scattering, constant stopping power, and no range struggling, a set of analytic formulas were derived. Comparisons of the distributions and typical parameters between simulations and the analytic model were conducted. Discrepancies were mostly caused by the three assumptions and were less than 3.7% for thrust and less than 3.9% for the proportion of escaped alpha-particles.
The plastic scintillator detector is widely used to measure pulsed radiation fields, and a high-quality neutron energy response curve is crucial for accurately determining neutron yields. Traditionally, the neutron energy response curve can be obtained by the simulation of the performance of neutron detectors via the knowledge of the light yield of secondary particles or direct measuring energy response. Both methods record signals by a data acquisition system in the counting mode. This work establishes a new model to directly measure the energy response to neutrons of a plastic scintillator detector in current mode with white source spectra. The plastic scintillator detector can be triggered externally. There is no signal loss and dead time, and it is possible to calibrate the neutron detector with a high-intensity neutron source. Efficiencies can be determined at all energies simultaneously, and a rapid calibration of the plastic scintillator detector is available. To validate the experimental results, the theoretical values are obtained by Geant4 simulation, and the results reproduce the shapes of the experimental curves reasonably well. The neutron energy response curves of the detector show that when the thickness of the scintillator is reduced from 3 to 1 mm, the reduction ratio of gamma signal intensity is greater than that of neutron signal intensity, which leads to an increase in the neutron–gamma sensitivity ratio. Meanwhile, the thin scintillator thickness can obtain a somewhat flatter neutron energy response curve compared with other thicknesses.
In high energy density physics, the demand for precise detection of nanosecond-level fast physical processes is high. Ga:ZnO (GZO), GaN, and other fast scintillators are widely used in pulsed signal detection. However, many of them, especially wide-bandgap materials, still face issues of low luminous intensity and significant self-absorption. Therefore, an enhanced method was proposed to tune the wavelength of materials via coating perovskite quantum dot (QD) films. Three-layer samples based on GZO were primarily investigated and characterized. Radioluminescence (RL) spectra from each face of the samples, as well as their decay times, were obtained. Lower temperatures further enhanced the luminous intensity of the samples. Its overall luminous intensity increased by 2.7 times at 60 K compared to room temperature. The changes in the RL processes caused by perovskite QD and low temperatures were discussed using the light tuning and transporting model. In addition, an experiment under a pico-second electron beam was conducted to verify their pulse response and decay time. Accordingly, the samples were successfully applied in beam state monitoring of nanosecond pulsed proton beams, which indicates that GZO wafer coating with perovskite QD films has broad application prospects in pulsed radiation detection.
9 December 2024 in IEEE Transactions on Instrumentation and Measurement
Scintillation detector is one of the key detectors for measurements of pulsed radiation fields due to its high sensitivity, and fast time response. In a scintillation detector, the photomultiplier tube need have a high gain, a fast temporal response, and a large maximum linear current (MLC). The hybrid photomultiplier tube based on a SiC detector (SiC-HPMT) with a larger MLC is expected to become one kind of the important photon detectors for the measurements of pulsed radiation fields with a high intensity. However, the inherent problem is that the currently used hybrid photomultiplier is severely restricted by a low gain. On the basis of maintaining the original excellent properties, such as fast temporal response and large MLC, a novel hybrid photomultiplier tube (MCP-SiC-HPMT) which is composed of SiC-HPMT and a microchannel plate (MCP) is developed to offer an effective way to improve the gain. According to the experimental results, the influence laws of the accelerating and focusing voltage and the bias voltage of the SiC detector on its properties such as the gain, dark current, temporal response, and MLC were obtained. The gain and the MLC of the MCP-SiC-HPMT can reach over 10 5 and 500 mA, respectively. Moreover, the result demonstrated that the temporal response of the MCP-SiC-HPMT has a leading edge of about 2 ns and a FWHM of about 4 ns, which is almost same as that of the SiC-HPMT. The addition of the MCP does not only improve their gain, but also have no significant impact on its excellent performance. The detector based on an EJ228 scintillator and the MCP-SiC-HPMT successfully measured the multiple peaks characteristic of a pulsed X-ray source, which indicated that the MCP-SiC-HPMT can well meet the requirements of the temporal characteristics measurement of a pulsed device. The detector combining a stilbene scintillator with the developed MCP-SiC-HPMT can well discriminate the neutron and gamma rays produced by a D-T neutron source. The successful development of the MCP-SiC-HPMT can further expand the applications in pulsed radiation field measurements and show the great potential in the field of particle detections for hybrid photomultiplier tubes (HPMTs).