This study investigates the broad-energy-spectrum reactor-neutron irradiation effects on the electrical characteristics of Ni/β-Ga2O3 Schottky barrier diodes (SBDs), where the irradiated neutron fluence was up to 1 × 1016 cm−2. On the one hand, the high neutron fluence of 1016 cm−2 resulted in a reduction in forward current density by two orders of magnitude and an extremely high on-resistance property due to the radiation-generated considerable series resistance in the SBD. On the other hand, the irradiation brought little influence on the Ni/β-Ga2O3 Schottky contact, since the extracted ideality factor and barrier height from temperature-dependent current–voltage (I–V–T) characteristics showed no significant changes after the radiation. Moreover, the capacitance–voltage (C–V) characterization revealed that the net carrier density in the β-Ga2O3 material was only reduced by 25% at the neutron fluence of 1015 cm−2 but a significant reduction by 2–3 orders at 1016 cm−2. Within the neutron fluence range of 2 × 1014 cm−2 up to 1016 cm−2, the carrier removal rates trended to be saturated with the increased fluences, following an exponential regular. In addition, the C–V measurement on the 1016 cm−2 irradiated sample exhibited an obvious frequency dispersion, and the extracted carrier distribution was not uniform.
X-ray response performances of a p-NiO/β-Ga2O3 hetero-junction diode (HJD) X-ray detector were studied before and after γ-ray irradiation at −200 V, with a total dose of 13.5 kGy(Si). The response performances of the HJD X-ray detector were influenced by the trap-assistant conductive process of the HJD under reverse bias, which exhibited an increasing net (response) current, nonlinearity, and a long response time. After irradiation, the Poole–Frenkel emission (PFE) dominated the leakage current of HJDs due to the higher electric field caused by the increased net carrier concentration of β-Ga2O3. This conductive process weakened the performance of the HJD X-ray detector in terms of sensitivity, output linearity, and response speed. This study provided valuable insights into the radiation damage and performance degradation mechanisms of Ga2O3-based radiation detectors and offered guidance on improving the reliability and stability of these radiation detectors.
To improve the radioluminescence (RL) performance of ZnO:Ga (GZO) crystal scintillators and overcome the challenge of their self-absorption, we proposed a two-layer composite scintillator consisting of a GZO wafer and a 70 nm lead halide perovskite film(CsPbBr3, CH3NH3PbBr3). The effects of the perovskite film on the RL properties were studied. The results showed that the perovskite quantum dot film substantially changed the RL spectrum of GZO and prevented self-absorption. The RL of the samples were enhanced by 66% to 151% through the photoluminescence (PL) of the perovskite film, while the energy-resolving power and spatial-resolving power were maintained at the same level as that of GZO image converters. The present experiments and discussions confirmed that the perovskite film improved the RL, and this study suggests a new wavelength regulation method among scintillators, converters, and back-end optical devices. The applications of perovskites in the field of radiation detection and imaging have been extended.
A new type of hybrid photon detector (HPD) based on SiC Schottky diode, with good radiation resistance and large sensitive area, has been constructed for either steady or pulsed light illumination. A series of experiments were carried out to examine its performance. As a result, the prototype SiC-HPD obtained a gain varying from 0 to 418, when the acceleration high voltage was up to 10 kV. In addition, the prototype SiC-HPD showed a nanoseconds time response with leading edge of 3.5 ns (FWHM similar to 16.6 ns) and a maximum output current around 0.65A under long pulse irradiation. The results indicate that the SiC-HPD is a very promising detector with high gain, fast-time-response and high pulse linearity current for the radiation-field measurements.
In this paper, a silicon carbide (SiC) phototransistor based on an open-base structure was fabricated and used as a radiation detector. In contrast to the exposed and thin sensitive region of traditional photo detectors, the sensitive region of the radiation detector was much thicker (30 μm), ensuring the high energy deposition of radiation particles. The response properties of the fabricated SiC npn radiation detector were characterized by high-energy X-ray illumination with a maximum X-ray photon energy of 30 keV. The SiC npn detector featured stable and clear response to the X-ray within 0.0766 Gy∙s−1 to 0.766 Gy∙s−1 below 300 V. Due to to the low leakage current of less than 1 nA and the fully depleted sensitive region, the bipolar-transistor-modeled SiC npn detector exhibited a clear common-emitter current gain of 5.85 at 200 V (under 0.383 Gy∙s−1), where the gain increased with bias voltage due to the Early effect and reached 7.55 at 300 V. In addition, the transient response of the SiC npn detector revealed a longer delay time than the SiC diode of the same size, which was associated with the larger effective capacitance of the npn structure. The npn detector with internal gain showed great potential in radiation detection.
The silicon carbide (SiC) Schottky diode (SBD) detector in a SiC hybrid photomultiplier tube (HPMT) generates signals by receiving photocathode electrons with an energy of 10 keV. So, the performance of the SiC SBD under electron irradiation with an energy of 10 keV has an important significance for the application of the SiC-HPMT. However, studies on 10 keV radiation effects on the SiC SBDs were rarely reported. In this paper, the performance degradation of the SiC SBDs irradiated by 10 keV electrons at different fluences was investigated. After the irradiation, the forward current of the SiC SBDs increased, and the turn-on voltage decreased with the irradiation fluences until 1.6 × 1016 cm−2. According to the capacitance–voltage (C-V) curves, the effective doping concentration increased slightly after the irradiation, and an obvious discrepancy of C-V curves occurred below 5 V. Moreover, as a radiation detector, the peak position of the α-particles’ amplitude spectrum changed slightly, and the energy resolution was also slightly reduced after the irradiation due to the high collection charge efficiency (CCE) still being larger than 99.5%. In addition, the time response of the SiC SBD to the 50 ns pulsed X-ray was almost not affected by the irradiation. The results indicated that the performance degradation of the SiC SBD irradiated at the fluence of 1.5 × 1017 cm−2 would not result in a deterioration of the properties of the SiC-HPMT and showed an important significance for the supplement of the radiation resistance of the SiC SBD radiation detector.