F. Wang

Dr. F. Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
SHShiyi He
Shiyi He
FWF. Wang
F. Wang
LCLiang Chen
Liang Chen
YLYang Li
Yang Li
JRJinlu Ruan
Jinlu Ruan
XOXiao-ping Ouyang
Xiao-ping Ouyang

24 December 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
WJWang Jing
Wang Jing
LZLeidang Zhou
Leidang Zhou
LCLiang Chen
Liang Chen
SZSilong Zhang
Silong Zhang
FWF. Wang
F. Wang
XOXiao-ping Ouyang
Xiao-ping Ouyang
In this paper, a silicon carbide (SiC) phototransistor based on an open-base structure was fabricated and used as a radiation detector. In contrast to the exposed and thin sensitive region of traditional photo detectors, the sensitive region of the radiation detector was much thicker (30 μm), ensuring the high energy deposition of radiation particles. The response properties of the fabricated SiC npn radiation detector were characterized by high-energy X-ray illumination with a maximum X-ray photon energy of 30 keV. The SiC npn detector featured stable and clear response to the X-ray within 0.0766 Gy∙s−1 to 0.766 Gy∙s−1 below 300 V. Due to to the low leakage current of less than 1 nA and the fully depleted sensitive region, the bipolar-transistor-modeled SiC npn detector exhibited a clear common-emitter current gain of 5.85 at 200 V (under 0.383 Gy∙s−1), where the gain increased with bias voltage due to the Early effect and reached 7.55 at 300 V. In addition, the transient response of the SiC npn detector revealed a longer delay time than the SiC diode of the same size, which was associated with the larger effective capacitance of the npn structure. The npn detector with internal gain showed great potential in radiation detection.

30 October 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
JRJinlu Ruan
Jinlu Ruan
LCLiang Chen
Liang Chen
LZLeidang Zhou
Leidang Zhou
XDXue Du
Xue Du
FWF. Wang
F. Wang
XOXiao-ping Ouyang
Xiao-ping Ouyang
The silicon carbide (SiC) Schottky diode (SBD) detector in a SiC hybrid photomultiplier tube (HPMT) generates signals by receiving photocathode electrons with an energy of 10 keV. So, the performance of the SiC SBD under electron irradiation with an energy of 10 keV has an important significance for the application of the SiC-HPMT. However, studies on 10 keV radiation effects on the SiC SBDs were rarely reported. In this paper, the performance degradation of the SiC SBDs irradiated by 10 keV electrons at different fluences was investigated. After the irradiation, the forward current of the SiC SBDs increased, and the turn-on voltage decreased with the irradiation fluences until 1.6 × 1016 cm−2. According to the capacitance–voltage (C-V) curves, the effective doping concentration increased slightly after the irradiation, and an obvious discrepancy of C-V curves occurred below 5 V. Moreover, as a radiation detector, the peak position of the α-particles’ amplitude spectrum changed slightly, and the energy resolution was also slightly reduced after the irradiation due to the high collection charge efficiency (CCE) still being larger than 99.5%. In addition, the time response of the SiC SBD to the 50 ns pulsed X-ray was almost not affected by the irradiation. The results indicated that the performance degradation of the SiC SBD irradiated at the fluence of 1.5 × 1017 cm−2 would not result in a deterioration of the properties of the SiC-HPMT and showed an important significance for the supplement of the radiation resistance of the SiC SBD radiation detector.

6 August 2025 in Materials
Verified
Journal Article
Open access
PDF file
SHShiyi He
Shiyi He
SZSilong Zhang
Silong Zhang
LCLiang Chen
Liang Chen
YLYang Li
Yang Li
FWF. Wang
F. Wang
XOXiao-ping Ouyang
Xiao-ping Ouyang
In high energy density physics, the demand for precise detection of nanosecond-level fast physical processes is high. Ga:ZnO (GZO), GaN, and other fast scintillators are widely used in pulsed signal detection. However, many of them, especially wide-bandgap materials, still face issues of low luminous intensity and significant self-absorption. Therefore, an enhanced method was proposed to tune the wavelength of materials via coating perovskite quantum dot (QD) films. Three-layer samples based on GZO were primarily investigated and characterized. Radioluminescence (RL) spectra from each face of the samples, as well as their decay times, were obtained. Lower temperatures further enhanced the luminous intensity of the samples. Its overall luminous intensity increased by 2.7 times at 60 K compared to room temperature. The changes in the RL processes caused by perovskite QD and low temperatures were discussed using the light tuning and transporting model. In addition, an experiment under a pico-second electron beam was conducted to verify their pulse response and decay time. Accordingly, the samples were successfully applied in beam state monitoring of nanosecond pulsed proton beams, which indicates that GZO wafer coating with perovskite QD films has broad application prospects in pulsed radiation detection.

8 April 2026 in Materials
Verified
Journal Article
Open access
PDF file
JYJingwei Yang
Jingwei Yang
FWF. Wang
F. Wang
LCLiang Chen
Liang Chen
TBTao Bo
Tao Bo
ZCZhifang Chai
Zhifang Chai
WLWenwen Lin
Wenwen Lin
Large-sized, room-temperature ultrafast scintillator single crystals are highly demanded for fast timing applications such as time of flight–positron emission tomography, high-speed medical imaging, and pulse heavy-ray detection. Sub-nanosecond scintillation was discovered in 16 mm sized CsPbCl3Brx single crystals in our previous research. In this work, the crystal size of CsPbCl3Br0.03 was enlarged to 2 inches (50.8 mm). Meanwhile, by precisely optimizing the vertical Bridgman growth process, we further increased the concentration of Br dopant to realize even faster scintillation decay. In this study, we conducted a series of tests on the grown crystals, including temperature-dependent photoluminescence tests, alpha particle excitation tests, X-ray imaging tests, etc. Via the strategy of the incorporation of Br2, Br dopant introduces highly efficient fast recombination centers in perovskite CsPbCl3Br0.03 crystals, resulting in an unprecedently fast scintillation decay time of 303 ps under 241Am α-particle excitation, which is significantly shorter than that of the pure CsPbCl3 and all other perovskites by at least two orders of magnitude. Benefiting from the excellent optical transparency and high crystalline quality of the CsPbCl3Br0.03 crystal, an X-ray spatial resolution of up to 20 lp/mm is achieved. These results further demonstrate the great potential of large-sized CsPbCl3Brx single crystals for fast timing applications.