Saeid Jalilzadeh

Prof. Saeid Jalilzadeh


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in ISA Transactions
Verified
Journal Article
Closed access
MHMina Heshmati
Mina Heshmati
RNReza Noroozian
Reza Noroozian
SJSaeid Jalilzadeh
Saeid Jalilzadeh
HSHossein Shayeghi
Hossein Shayeghi

9 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
BEBehzad Esmaeilnezhad
Behzad Esmaeilnezhad
HAHossein Amini
Hossein Amini
RNReza Noroozian
Reza Noroozian
SJSaeid Jalilzadeh
Saeid Jalilzadeh
The primary objective when operating a distribution network is to minimize operating costs while taking technical constraints into account. Minimizing the operational costs is difficult when there is a high penetration of renewable resources and variability of loads, which introduces uncertainty. In this paper, a flexible, dynamic reconfiguration model is developed that enables a distribution network to minimize operating costs on an hourly basis. The model fitness function is to minimize the system costs, including power loss, voltage deviation, purchased power from the upstream network, renewable generation, and switching costs. The uncertainty of the load and generation from renewable energies is planned to use their probability density functions via a scenario-based approach. The suggested optimization problem is solved using a metaheuristic approach based on the coati optimization algorithm (COA) due to the nonlinearity and non-convexity of the problem. To evaluate the performance of the presented approach, it is validated on the IEEE 33-bus radial system and TPC 83-bus real system. The simulation results show the impact of dynamic reconfiguration on reducing operation costs. It is found that dynamic reconfiguration is an efficient solution for reducing power losses and total energy drawn from the upstream network by increasing the number of switching operations.

28 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
YByaser bostani
yaser bostani
SJSaeid Jalilzadeh
Saeid Jalilzadeh
Saleh MobayenSaleh Mobayen
Saleh Mobayen
TRThaned Rojsiraphisal
Thaned Rojsiraphisal
Andrzej BartoszewiczAndrzej Bartoszewicz
Andrzej Bartoszewicz
This paper presents a novel fuzzy control scheme for damping the subsynchronous resonance (SSR) according to the wide-area measurement system (WAMS) in power systems including doubly fed induction generator (DFIG)-based wind farms connected to series capacitive compensated transmission networks. The SSR damping is attained by adding the fuzzy controller as a supplementary signal at the stator voltage loop of the grid-side converter (GSC) of DFIG wind farms. Additionally, time delays due to communication signals are important when using WAMSs. If the time delays are ignored, it causes system instability. In this paper, the time delays are modeled with a separate fuzzy input to the controller. The new fuzzy control approach is executed by using the angular velocity of synchronous generators (w) and its variation in the angular velocity (dw/dt). The effectiveness and success of the WAMS-based fuzzy controller is demonstrated by comparison with the particle swarm optimization (PSO) and imperialist competitive algorithm (ICA) optimization methods. The efficacy and validity of the planned auxiliary damping control are verified on a modified version of the IEEE second benchmark model including DFIG-based wind farms via time simulations using the MATLAB/Simulink toolbox.

30 November 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Masoud KhatibiMasoud Khatibi
Masoud Khatibi
SJSaeid Jalilzadeh
Saeid Jalilzadeh
AHArif Hussain
Arif Hussain
Waseem HaiderWaseem Haider
Waseem Haider
Transient stability improvement of power systems in the event of short-circuit faults has always been an important issue in power systems analysis and studies. Resistive-type superconducting fault current limiters (RSFCL), owing to their capability in restricting fault currents, have been often taken into account as an efficient method to improve the transient stability of a power system. Regarding technical constraints as well as economic concerns, optimal allocation and sizing of RSFCLs in a power system play a crucial role in their efficient utilization. This paper aims to continue the authors’ previous work and enhance the transient stability of power systems by proposing an optimization approach for optimal sizing and the allocation of various candidate numbers of RSFCLs, as the most employed type of SFCL and the most efficient one in transient stability improvement. To solve the optimization problem, a PSO-based algorithm is solved in MATLAB through an objective function and related constraints. The efficacy of the proposed algorithm is evaluated by numerical studies on the IEEE 39-Bus New England system in various scenarios through the assessment of critical fault clearing time (CCT) as well as the generators rotor angle deviations as two crucial criteria for the transient stability of power systems. Simulating the optimization results in DIgSILENT Power Factory indicates an evident enhancement of the power system transient stability via employing optimized RSFCLs resulted from the proposed optimization algorithm. Moreover, the level of transient stability enhancement highly depends on the number of optimized RSFCLs employed in the power system. The results of this paper present a helpful guideline for power system planners to select an appropriate stability scheme based on RSFCLs besides other related technical and economic issues.

17 January 2019 in IETE Journal of Research
Verified
Journal Article
Closed access
MPMajid Pakdel
Majid Pakdel
ATAsghar Taheri
Asghar Taheri
SJSaeid Jalilzadeh
Saeid Jalilzadeh
The current study proposes a novel zero voltage and zero current (ZVZCS) soft switching pulse-width modulated (PWM) DC–DC boost converter. In the proposed converter, the main switch and the auxiliary switch are turned on by zero voltage switching (ZVS) and off by zero current switching (ZCS). There is no additional voltage or current stress on the power switches. The proposed topology has a simple structure. The strategy used to control the power devices is simple and implementation is straightforward. The proposed topology for the soft switching PWM DC–DC boost converter was analysed using simulation, and an experimental prototype was built to verify the theoretical analysis and simulation results.

15 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
YBYaser Bostani
Yaser Bostani
SJSaeid Jalilzadeh
Saeid Jalilzadeh
Saleh MobayenSaleh Mobayen
Saleh Mobayen
Afef FekihAfef Fekih
Afef Fekih
WAWudhichai Assawinchaichote
Wudhichai Assawinchaichote
This paper proposes an auxiliary damping control approach based on the wide-area measurement system (WAMS). Its main objective is to mitigate sub-synchronous resonance (SSR) in doubly fed induction generator (DFIG)-based wind farms connected to a series capacitive compensated transmission network. To mitigate the delay in sending measurement signals, typically associated with wide-area measurement systems, a fuzzy logic wide-area damping controller (FLWADC) is considered to mitigate the time delay caused by the phasor measurement unit (PMU) measurement. The FLWADC is a supplementary signal at the stator voltage of the grid-side converter (GSC) of the DFIG-based wind farms. The FLWADC was executed by using the voltage and capacitor voltage variations of the series capacitive compensated transmission network. The effectiveness and validity of the proposed auxiliary damping control was verified using a modified scheme of the IEEE first benchmark model via time-area simulation analysis using MATLAB/Simulink.