Reza Noroozian

Prof. Reza Noroozian

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
HHHossein Haddadian
Hossein Haddadian
RNReza Noroozian
Reza Noroozian
In a novel approach, this paper investigates the effect of demand response (DR) programs simultaneous with multi-microgrids-based operation of active distribution networks. In the proposed model, the possibility of microgrids (MGs) construction is evaluated through technical indices such as supply-adequacy, efficiency, voltage profile, and reliability as well as DR transaction costs. This multi-objective optimization problem is solved by a powerful method named non-dominated genetic algorithm-II (NSGA-II). Due to the probabilistic nature of renewable energy sources (RESs), loads, and energy prices, they are modeled using their probability density functions by Monte Carlo simulation algorithm. Also, the backward-forward load flow method is employed for obtaining the objective function parameters. The results of the proposed model are compared with the conventional operation method in various scenarios by implementing it on IEEE 69-bus test distribution system.

6 June 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MBMohsen Bakhshi
Mohsen Bakhshi
RNReza Noroozian
Reza Noroozian
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
This paper proposes a novel, passive-based antiislanding method for both inverter and synchronous machinebased distributed generation (DG) units. Unfortunately, when the active/ reactive power mismatch is near to zero, the majority of passive anti-islanding methods cannot detect the islanding situation. This study introduces a new islanding detection method based on the chaos theory that can detect the islanding condition with near-zero active power mismatch. The method uses the modified frequency of the point of common coupling (PCC) link as an input signal of forced Helmholtz oscillator. The obvious change between chaotic and normal motions in the forced Helmholtz oscillator is its main advantage over other oscillators. This change determines the threshold for detection index. The non-islanding transient events, which can cause a significant deviation in the frequency-based input signal of detector, are considered in simulations for two different case studies. These events include different types of faults, load changes, capacitor bank switching, and motor starting. Further, for islanding events, the capability of the proposed islanding detection method is verified by near-to-zero active power mismatches and UL 1741- based load imbalance tests.

9 July 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HBHamed Bizhani
Hamed Bizhani
RNReza Noroozian
Reza Noroozian
S.M. MuyeenS.M. Muyeen
S.M. Muyeen
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
This paper proposes a novel unified expandable low switch power electronic converter architecture for grid integration of direct drive variable speed wind turbine (VSWT) system using permanent magnet synchronous generator (PMSG). The proposed unified expandable power converter (UEPC) can interface two or more bidirectional output ports such as wind generators, energy storages and grid. The size of the power converter is compact because of low number of power electronic switches and protection devices and its architecture is easily expandable to accommodate more outputs, i.e., in this case, the wind turbines. A generalized sequential space vector modulation technique is developed based on the operational principle of the proposed converter to control of the outputs autonomously in order to track maximum power point for individual VSWTSs driven PMSG's. It is expected that the proposed approach will reduce the cost of power electronic converters in a wind farm compared to both AC- and DC-link based topologies, which are available for the moment

9 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
BEBehzad Esmaeilnezhad
Behzad Esmaeilnezhad
HAHossein Amini
Hossein Amini
RNReza Noroozian
Reza Noroozian
SJSaeid Jalilzadeh
Saeid Jalilzadeh
The primary objective when operating a distribution network is to minimize operating costs while taking technical constraints into account. Minimizing the operational costs is difficult when there is a high penetration of renewable resources and variability of loads, which introduces uncertainty. In this paper, a flexible, dynamic reconfiguration model is developed that enables a distribution network to minimize operating costs on an hourly basis. The model fitness function is to minimize the system costs, including power loss, voltage deviation, purchased power from the upstream network, renewable generation, and switching costs. The uncertainty of the load and generation from renewable energies is planned to use their probability density functions via a scenario-based approach. The suggested optimization problem is solved using a metaheuristic approach based on the coati optimization algorithm (COA) due to the nonlinearity and non-convexity of the problem. To evaluate the performance of the presented approach, it is validated on the IEEE 33-bus radial system and TPC 83-bus real system. The simulation results show the impact of dynamic reconfiguration on reducing operation costs. It is found that dynamic reconfiguration is an efficient solution for reducing power losses and total energy drawn from the upstream network by increasing the number of switching operations.

1 November 2017 in ISA Transactions
Verified
Journal Article
Closed access
MBM. Bakhshi
M. Bakhshi
RNReza Noroozian
Reza Noroozian
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian

3 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
HAHossein Amini
Hossein Amini
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
RNReza Noroozian
Reza Noroozian
Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.