Hossein Amini

Mr. Hossein Amini

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
BEBehzad Esmaeilnezhad
Behzad Esmaeilnezhad
HAHossein Amini
Hossein Amini
RNReza Noroozian
Reza Noroozian
SJSaeid Jalilzadeh
Saeid Jalilzadeh
The primary objective when operating a distribution network is to minimize operating costs while taking technical constraints into account. Minimizing the operational costs is difficult when there is a high penetration of renewable resources and variability of loads, which introduces uncertainty. In this paper, a flexible, dynamic reconfiguration model is developed that enables a distribution network to minimize operating costs on an hourly basis. The model fitness function is to minimize the system costs, including power loss, voltage deviation, purchased power from the upstream network, renewable generation, and switching costs. The uncertainty of the load and generation from renewable energies is planned to use their probability density functions via a scenario-based approach. The suggested optimization problem is solved using a metaheuristic approach based on the coati optimization algorithm (COA) due to the nonlinearity and non-convexity of the problem. To evaluate the performance of the presented approach, it is validated on the IEEE 33-bus radial system and TPC 83-bus real system. The simulation results show the impact of dynamic reconfiguration on reducing operation costs. It is found that dynamic reconfiguration is an efficient solution for reducing power losses and total energy drawn from the upstream network by increasing the number of switching operations.

3 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
HAHossein Amini
Hossein Amini
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
RNReza Noroozian
Reza Noroozian
Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

23 April 2025 in IEEE Access
Verified
Journal Article
Open access
HAHossein Amini
Hossein Amini
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
RNReza Noroozian
Reza Noroozian
Unintentional islanding occurs when a microgrid continues operating independently after disconnection from the main grid, which can lead to voltage and frequency instability, power quality degradation, and safety risks. Few local and remote methods consider islanding detection in noisy environments. Noise can interfere with measurements and cause failed or delayed islanding detection. This paper proposes a hybrid islanding detection method that utilizes a Van der Pol Duffing oscillator (VDPDO), focusing on decreasing the detection period, zero power mismatch nondetection zone, and power quality degradation. The proposed method uses the fast Fourier transform (FFT) symmetry characteristic of a hybrid VDPDO (HVDPDO) output signal and addresses the set point threshold using the Melnikov function. This method detects the changes in frequency, phase, and voltage amplitude of the point of common coupling (PCC) simultaneously to distinguish islanded operation from other faults. For the asymmetric FFT waveform of the passive HVDPDO, the islanding system sends a signal to the inverter to change the mode from grid-following to grid-forming and injects perturbations into the frequency, phase, and voltage amplitude, simultaneously. The active HVDPDO detects islanded operations with a small non-detection zone. The inverter reverts to grid-following mode for other faults, and the main grid damps the intentionally small perturbations. Simulation and experimental results validate that the proposed method meets the IEEE standard 1547 criteria.

10 April 2025 in Electricity
Verified
Journal Article
Open access
PDF file
HAHossein Amini
Hossein Amini
RNReza Noroozian
Reza Noroozian
This paper discusses the operation and control of a low-voltage DC (LVDC) isolated distribution network powered by distributed generation (DG) from a variable-speed wind turbine induction generator (WTIG) to supply unbalanced AC loads. The system incorporates a DC-DC storage converter to regulate network voltages and interconnect battery energy storage with the DC network. The wind turbines are equipped with a squirrel cage induction generator (IG) to connect a DC network via individual power inverters (WTIG inverters). Loads are unbalanced ACs and are interfaced using transformerless power inverters, referred to as load inverters. The DC-DC converter is equipped with a novel control strategy, utilizing a droop regulator for the DC voltage to stabilize network operation. The control system is modeled based on Clark and Park transformations and is developed for the load inverters to provide balanced AC voltage despite unbalanced load conditions. The system employs the perturbation and observation (P&O) method for maximum power point tracking (MPPT) to optimize wind energy utilization, while blade angle controllers maintain generator performance within rated power and speed limits under high wind conditions. System operation is analyzed under two scenarios: normal operation with varying wind speeds and the effects of load variations. Simulation results using PSCAD/EMTDC demonstrate that the proposed LVDC isolated distribution network (DC) achieves a stable DC bus voltage within ±5% of the nominal value, efficiently delivers balanced AC voltages with unbalanced levels below 2%, and operates with over 90% wind energy utilization during varying wind speeds, confirming LVDC network reliability and robustness.