Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.
Objectives: The aim of this retrospective study was to analyze peri-implant marginal bone loss levels/rates and peri-implant sulcular fluid levels/rates of metalloproteinase-8 in three timeframes (6 months post-surgery—restoration delivery (T0)—and 6 (T6) and 24 (T24)-months post-loading) and to evaluate if there is a correlation between peri-implant sulcular fluid levels of metalloproteinase-8 and peri-implant marginal bone loss progression. Materials and Methods: Two cohorts of patients undergoing implant surgery between January 2017 and January 2019 were selected in this retrospective study. A total of 39 patients received 39 implants with a laser-microtextured collar surface, and 41 subjects received 41 implants with a machined/smooth surface. For each patient, periapical radiographs and a software package were used to measure marginal bone loss rates. Implant fluid samples were analyzed by an enzyme-linked immunosorbent assay (ELISA) test. The modified plaque index, probing depth, and bleeding on probing were also recorded. Results: High marginal bone rates at T24 were strongly associated with elevated rates between T0 and T6. The levels of metalloproteinase-8 were significantly more elevated around implants with marginal bone loss, in relation to implants without marginal bone loss. Marginal bone loss (MBL) rates at 24 months were associated with initial bone loss rates and initial levels of metalloproteinase-8. Conclusions: Peri-implant marginal bone loss progression is statistically correlated to peri-implant sulcular fluid levels of metalloproteinase-8. Moreover, the initial high levels of marginal bone loss and metalloproteinase-8 can be considered as indicators of the subsequent progression of peri-implant MBL: implants with increased marginal bone loss rates and metalloproteinase-8 levels at 6 months after loading are likely to achieve additional marginal bone loss values.
(1) The possibility of knowing information about the anatomy in advance, in particular the arrangement of the endodontic system, is crucial for successful treatment and for avoiding complications during endodontic therapy; the aim was to find a correlation between a minimally invasive and less stressful endodontic access on Ni-Ti rotary instruments, but which allows correct vision and identification of anatomical reference points, simplifying the typologies based on the shape of the pulp chamber in coronal three-dimensional exam views. (2) Based on the inclusion criteria, 104 maxillary molars (52 maxillary first molars and 52 maxillary second molars) were included in the study after 26 Cone Beam Computed Tomography (CBCT) acquisitions (from 15 males and 11 females). And linear measurements were taken with the CBCT-dedicated software for subsequent analysis. (3) The results of the present study show data similar to those already published about this topic. Pawar and Singh’s simplified classification actually seems to offer a schematic way of classification that includes almost all of the cases that have been analyzed. (4) The use of a diagnostic examination with a wide Field of View (FOV) and low radiation dose represents an exam capable of obtaining a lot of clinical information for endodontic treatment. Nevertheless, the endodontic anatomy of the upper second molar represents a major challenge for the clinician due to its complexity both in canal shape and in ramification.
1 January 2021 in The Journal of Contemporary Dental Practice
The main drawback of several studies is the limited analysis performed for the comparison of nickel-titanium (NiTi) rotary systems. Most often, research articles in this area are focalized on the static characteristics such as static cyclic fatigue, torsional loads, and flexibility, not considering their reciprocal interaction and all dynamic factors.1 Recent evidence in the literature defines the reciprocal interaction between these parameters as a fundamental element in the study of their mechanical characteristics.2 However, static mechanical behavior is fundamental to assess the basic performance of NiTi instruments, but its interpretation during clinical practice is pointless as it does not resemble the real clinical scenario.1,3,4 Results arising from static tests, certainly valid as a first approach to the evaluation of an instrument recently introduced on the market, and comparative evaluations, should be considered in a general and more complete view, considering their reciprocal relationships.3-6 For these reasons, different types of researches that investigate both static and dynamic performance of NiTi instruments should be strongly recommended in order to give to original research and in vitro study an actual clinical significance, certainly much more indicative in view of a subsequent clinical application of NiTi rotary instruments.7-9.