Objectives: The aim of this retrospective study was to analyze peri-implant marginal bone loss levels/rates and peri-implant sulcular fluid levels/rates of metalloproteinase-8 in three timeframes (6 months post-surgery—restoration delivery (T0)—and 6 (T6) and 24 (T24)-months post-loading) and to evaluate if there is a correlation between peri-implant sulcular fluid levels of metalloproteinase-8 and peri-implant marginal bone loss progression. Materials and Methods: Two cohorts of patients undergoing implant surgery between January 2017 and January 2019 were selected in this retrospective study. A total of 39 patients received 39 implants with a laser-microtextured collar surface, and 41 subjects received 41 implants with a machined/smooth surface. For each patient, periapical radiographs and a software package were used to measure marginal bone loss rates. Implant fluid samples were analyzed by an enzyme-linked immunosorbent assay (ELISA) test. The modified plaque index, probing depth, and bleeding on probing were also recorded. Results: High marginal bone rates at T24 were strongly associated with elevated rates between T0 and T6. The levels of metalloproteinase-8 were significantly more elevated around implants with marginal bone loss, in relation to implants without marginal bone loss. Marginal bone loss (MBL) rates at 24 months were associated with initial bone loss rates and initial levels of metalloproteinase-8. Conclusions: Peri-implant marginal bone loss progression is statistically correlated to peri-implant sulcular fluid levels of metalloproteinase-8. Moreover, the initial high levels of marginal bone loss and metalloproteinase-8 can be considered as indicators of the subsequent progression of peri-implant MBL: implants with increased marginal bone loss rates and metalloproteinase-8 levels at 6 months after loading are likely to achieve additional marginal bone loss values.
The aim of the present study is twofold: to assess ex vivo the role of different lubricants on real-time torque generated during intracanal instrumentation and to check whether two different kinds of torque parameters, operative torque (OT) and average peak torque (APT), could produce similar results. Forty extracted single-rooted teeth were selected for the present study and divided into four equal groups (n = 10): Group A, NaCl 0.2%; Group B, NaOCl 5%; Group C, ethylenediaminetetraacetate (EDTA), and Group D, EDTA and hydrogen peroxide. Afterwards, Edge Taper F2 (Edge Endo, Albuquerque, New Mexico) were rotated clockwise at 300 rpm with 3 Ncm maximum torque by an endodontic torque recording motor. In each sample, mean OT and mean APT were recorded and statistically analyzed with one-way ANOVA and a post hoc Bonferroni between groups (p < 0.05). EDTA (12.11 ± 4.45 Ncm) showed statistically significant (p < 0.05) lower values compared with the other tested irrigant for both parameters. Overall, the two different parameters were both able to differentiate between the influence of lubricants on torsional loads.
The action of stem cells is mediated by their paracrine secretions which comprise the secretory profile. Various approaches can be used to modify the secretory profile of stem cells. Creating a hypoxic environment is one method. The present study aims to demonstrate the influence of CoCl2 in generating hypoxic conditions in a dental pulp stem cell (DPSCs) culture, and the effect of this environment on their secretory profile. DPSCs that were isolated from human permanent teeth were characterized and treated with different concentrations of CoCl2 to assess their viability by an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and proliferation by a cell counting kit (CCK)-8 assay. The gene expression level of hypoxia-inducible factor 1-alpha (HIF-1α) was analyzed by quantitative real time polymerase chain reaction (qRT-PCR) to demonstrate a hypoxic environment. Comparative evaluation of the growth factors and cytokines were done by cytometric bead array. Gene expression levels of transcription factors OCT4 and SOX2 were analyzed by qRT-PCR to understand the effect of CoCl2 on stemness in DPSCs. DPSCs were positive for MSC-specific markers. Doses of CoCl2, up to 20 µM, did not negatively affect cell viability; in low doses (5 µM), it promoted cell survival. Treatment with 10 µM of CoCl2 significantly augmented the genetic expression of HIF-1α. Cells treated with 10 µM of CoCl2 showed changes in the levels of growth factors and cytokines produced. It was very evident that CoCl2 also increased the expression of OCT4 and SOX2, which is the modulation of stemness of DPSCs. A CoCl2 treatment-induced hypoxic environment modulates the secretory profile of DPSCs.
The aims of the present study were to propose a new machine for testing the bending behavior of an instrument at multiple specific points along the cutting surface and to compare the influence of proprietary heat treatment on the bending ability of EdgeTaper (ET), Protaper Universal (PTU), EdgeTaper Platinum (ETP), and Protaper Gold (PTG). A total of 320 instruments were examined in the present study: 80 ET, 80 PTU, 80 ETP, and 80 PTG. The bending ability of all instruments was tested at a 45° angle and on three different portions of the instrument at 3, 6, and 9 mm from the tip using a customized device. Statistical analysis showed significant differences among each single instrument of the series and between ET and PTU as well as ETP and PTG. The bending behavior of a nickel–titanium rotary instrument is its ability to bend without any plastic deformation. This feature, according to the results of the present study, is variable along the cutting surface; therefore, it should be evaluated. Due to the present testing device, it would be possible to obtain reliable and trustworthy information about an instrument’s bending ability.
The aim of the present study is to evaluate operative torque, torque at failure and the difference between these two values—the “torque range”—of two different NiTi files. We also sought to evaluate and compare these parameters for new and used files. Forty S-One 20.06 and forty M-Two 20.06 were tested, divided in four equal groups (n = 10) for each brand. Ten instruments from each brand performed three root canal treatments each on standardized extracted single-rooted teeth. Afterwards, each group was subjected to the following two tests: operative torque and torsional resistance. Mean values for all the tested groups were calculated. The results for new instruments showed that S-One developed significantly higher operative torque, but higher torsional resistance. The results for used instruments showed that the S-One 20.06 developed less operative torque and higher mean torsional resistance value compared to the M-Two. Moreover, the percentage reduction of both values was significantly higher for M-Two. The results of the present study showed a safer torsional behavior of the S-One. These results could be related to the heat treatment and the manufacturing process.
The aim of the present study is to evaluate the setting and sealant ability of two different bioceramic sealers in two different environmental conditions: humid and wet environment. Ex vivo root canal treatment was performed on 24 freshly extracted teeth. Irrigation was performed with Niclor NaOCl 5% and EDTA 17%, then obturated with a bioceramic sealer in the two different environmental conditions listed above. Furthermore, scanning electron microscope (SEM) investigation was performed to verify the presence of gaps and the setting ability of the two sealers in two different environmental conditions was evaluated. While presence of gaps was found mainly in the wet specimens, on the other hand, regarding the setting ability, there is no statistically significant difference between the two different samples. Therefore, even if humid conditions represent the gold standard in terms of lower gaps dimension, since there is no methodology standardizing the drying procedure of the root canal, it is compulsory to investigate the sealing ability of the bioceramic sealers, even in wet conditions. Thanks to the findings shown in the present study, it is demonstrated that even in wet conditions the ability of the sealer to set does not change and such clinical situation could affect the bioceramic sealer protocol.