Ana Budimir

Prof. Dr. Ana Budimir

Department of Clinical and Molecular Microbiology, School of Medicine, University of Zagreb, 10000 Zagreb, Croatia

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

31 October 2021 in Fibers
Verified
Journal Article
Open access
PDF file
EMEva Magovac
Eva Magovac
BVBojana Voncina
Bojana Voncina
ABAna Budimir
Ana Budimir
IJIgor Jordanov
Igor Jordanov
Jaime GrunlanJaime Grunlan
Jaime Grunlan
SBSandra Bischof
Sandra Bischof
Environmentally benign layer-by-layer (LbL) deposition was used to obtain flame-retardant and antimicrobial cotton. Cotton was coated with 8, 10, and 12 phytic acid (PA) and chitosan (CH)-urea bilayers (BL) and then immersed into copper (II) sulfate (CuSO4) solution. Our findings were that 12 BL of PA/CH-urea + Cu2+ were able to stop flame on cotton during vertical flammability testing (VFT) with a limiting oxygen index (LOI) value of 26%. Microscale combustion calorimeter (MCC) data showed a reduction of peak heat release rates (pHRR) of more than 61%, while the reduction of total heat release (THR) was more than 54%, relative to untreated cotton. TG-IR analysis of 12 BL-treated cotton showed the release of water, methane, carbon dioxide, carbon monoxide, and aldehydes, while by adding Cu2+ ions, the treated cotton produces a lower amount of methane. Treated cotton also showed no levoglucosan. The intumescent behavior of the treatment was indicated by the bubbled structure of the post-burn char. Antibacterial testing showed a 100% reduction of Klebsiella pneumoniae and Staphylococcus aureus. In this study, cotton was successfully functionalized with a multifunctional ecologically benign flame-retardant and antibacterial nanocoating, by means of LbL deposition.

12 July 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
LMLuka Morelato
Luka Morelato
ABAna Budimir
Ana Budimir
Igor SmojverIgor Smojver
Igor Smojver
IKIvan Katalinić
Ivan Katalinić
MVMarko Vuletić
Marko Vuletić
DGDragana Gabric
Dragana Gabric
Background: Antimicrobial photodynamic therapy (PDT) has been introduced as a potential option for peri-implantitis treatment. The aim of this study is to evaluate the antimicrobial effect of a novel technique involving a combination of 445 nm diode laser light with 0.1% riboflavin solution (used as a photosensitizing dye) as applied on a bacterial–fungal biofilm formed on implants and to compare the performance of this technique with that of the commonly used combination of 660 nm diode laser with 0.1% methylene blue dye. Methods: An in vitro study was conducted on 80 titanium dental implants contaminated with Staphylococcus aureus (SA) and Candida albicans (CA) species. The implants were randomly divided into four groups: negative control (NC), without surface treatment; positive control (PC), treated with a 0.2% chlorhexidine (CHX)-based solution; PDT1, 660 nm (EasyTip 320 µm, 200 mW, Q power = 100 mW, 124.34 W/cm2, 1240 J/cm2) with a 0.1% methylene blue dye; and PDT2, 445 nm (EasyTip 320 µm, 200 mW, Q power = 100 mW, 100 Hz, 124.34 W/cm2, 1.24 J/cm2) with a 0.1% riboflavin dye. Results: The PDT1 and PDT2 groups showed greater reduction of SA and CA in comparison to the NC group and no significant differences in comparison to the PC group. No statistically significant differences between the PDT1 and PDT2 groups were observed. Conclusions: A novel antimicrobial treatment involving a combination of 445 nm diode laser light with riboflavin solution showed efficiency in reducing SA and CA biofilm formation on dental implant surfaces comparable to those of the more commonly used PDT treatment consisting of 660 nm diode laser light with methylene blue dye or 0.2% CHX treatment.

24 March 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
IKIvan Katalinić
Ivan Katalinić
Igor SmojverIgor Smojver
Igor Smojver
LMLuka Morelato
Luka Morelato
MVMarko Vuletić
Marko Vuletić
ABAna Budimir
Ana Budimir
DGDragana Gabric
Dragana Gabric
Photoactivation of 3% hydrogen peroxide with a 445 nm diode laser represents a relatively new, insufficiently researched antimicrobial method in the treatment of peri-implantitis. The purpose of this work is to evaluate the effect of photoactivation of 3% hydrogen peroxide with a 445 nm diode laser, and to compare the obtained results with 0.2% chlorhexidine treatment and 3% hydrogen peroxide treatment without photoactivation, in vitro, on the surface of dental implants contaminated with S. aureus and C. albicans biofilms. Previously, 80 infected titanium implants with S. aureus and C. albicans cultures were divided into four groups: G1-negative control (no treatment), G2-positive control (0.2% chlorhexidine), G3 (3% hydrogen peroxide), and G4 (photoactivated 3% hydrogen peroxide). The number of viable microbes in each sample was determined by the colony forming unit (CFU) count. The results were statistically processed and analyzed, showing a statistically significant difference across all groups compared to the negative control (G1), and the absence of a statistically significant difference between groups G1–G3. The new antimicrobial treatment, according to the results, could be worthy of further analysis and research.

30 October 2022 in Life
Verified
Journal Article
Open access
PDF file
GPGabrijela Perše
Gabrijela Perše
ISIvana Samošćanec
Ivana Samošćanec
ZBZrinka Bośnjak
Zrinka Bośnjak
ABAna Budimir
Ana Budimir
TKTomislav Kulis
Tomislav Kulis
IMIvana Mareković
Ivana Mareković
In order to further accelerate pathogen identification from positive blood cultures (BC), various sample preparation protocols to identify bacteria with MALDI-TOF MS directly from positive BCs have been developed. We evaluated an in-house method in comparison to the Sepsityper® Kit (Bruker Daltonics, Bremen, Germany) as well as the benefit of an on-plate formic acid extraction step following positive signal by the BACTECTM FX system. Confirmation of identification was achieved using subcultured growing biomass used for MALDI-TOF MS analysis. A total of 113 monomicrobial positive BCs were analyzed. The rates of Gram-positive bacteria correctly identified to the genus level using in-house method and Sepsityper® Kit were 63.3% (38/60) and 81.7% (49/60), respectively (p = 0.025). Identification rates at species level for Gram-positive bacteria with in-house method and Sepsityper® kit were 30.0% (18/60) and 66.7% (40/60), respectively (p < 0.001). Identification rates of Gram-negative bacteria were similar with the in-house method and Sepsityper® Kit. Additional on-plate formic acid extraction demonstrated significant improvement in the identification rate of Gram-positive bacteria at both genus and species level for both in-house (p = 0.001, p < 0.001) and Sepsityper® Kit methods (p = 0.007, p < 0.001). Our in-house method is a candidate for laboratory routines with Sepsityper® Kit as a back-up solution when identification of Gram-positive bacteria is unsuccessful.

1 November 2014 in American Journal of Infection Control
Verified
Journal Article
Closed access
ABAna Budimir
Ana Budimir
MPMarina Payerl Pal
Marina Payerl Pal
ZBZrinka Bošnjak
Zrinka Bošnjak
IMIvana Mareković
Ivana Mareković
DVDubravka Vuković
Dubravka Vuković
SKSmilja Kalenić
Smilja Kalenić