6G wireless communications will be immersed in the future with different applications. It is expected to support all IoT services and satellite communications, and it is expected to support artificial intelligence (AI) and machine learning (ML). The THz frequency band has a vital role in 6G communication. In this study, a new graphene plasmonic two-port Terahertz (THz) MIMO antenna is analyzed by the characteristic mode theory (CMA), which gives a better insight into the physical behavior of the MIMO configurations. The proposed MIMO antenna is compact and designed on a Teflon substrate of 130 × 85 µm2. The antenna provides a wide impedance bandwidth of 0.6 THz (3.2–3.8 THz). The CMA is applied to clarify the position at which the mutual coupling gives a maximum concentrated current distribution. It is mainly used to reveal the preferable MIMO antenna configuration by the usage of the model significant and model current distribution property. To reduce the mutual coupling between the radiating elements, a complementary dumbbell-structure Metamaterial (MTM) unit cell is etched in the ground plane to block the coupling mode without any affection on the dominant mode. The preferred MIMO configuration gives high isolation of −55 dB between the radiating patches. The fundamental characteristics have been discussed in detail. The proposed MIMO design offers several attractive features such as large bandwidth of 0.6 THz, low envelope correlation coefficient (ECC) of 0.000168, compact size, stable radiation, high gain of 7.23 dB, and low channel capacity loss (CCL) of 0.006. The proposed MIMO design is suitable for different applications in the THz band according to the high-performance parameters such as biomedical applications, security scanning, sensing, IoT, and 6G high-speed wireless communication systems.
The approaching sixth-generation (6G) communication network will modernize applications and satisfy user demands through implementing a smart and reconfigurable system with a higher data rate and wider bandwidth. The controllable THz waves are highly recommended for the instantaneous development the new technology in wireless communication systems. Recently, reconfigurable intelligent surfaces (RIS), also called codded/tunable programmable metasurfaces, have enabled a conspicuous functionality for THz devices and components for influencing electromagnetic waves (EM) such as beam steering, multi-beam-scanning applications, polarization variation, and beam focusing applications. In this article, we proposed a graphene plasmonic two-port MIMO microstrip patch antenna structure that operates at a 1.9 THz resonance frequency. An E-shape MTM unit cell is introduced to enhance the isolation of the antenna from −35 dB to −54 dB. An implementation of controllable and reconfigurable surfaces based on graphene meta-atoms (G-RIS) placed above the radiating patches with a suitable separated distance to control the radiated beam to steer in different directions (±60°). The reconfigurable process is carried out via changing the (ON/OFF) meta-atoms states to get a specific code with a certain beam direction. The gain enhancement of the antenna can be implemented through an artificial magnetic conductor (AMC) based on graphene material. The G-AMC layer is located underneath the (MIMO antenna, G-RIS layer) to improve the gain from 4.5 dBi to 10 dBi. The suggested antenna structure results are validated with different techniques CST microwave studio and ADS equivalent circuit model. The results have asymptotic values. So, the proposed design of the MIMO antenna that is sandwiched between G-RIS and G-AMC is suitable for IoT applications.
This paper proposes a wideband ultra-compact implantable antenna for a wireless body area network (WBAN). The proposed patch antenna works in the industrial, scientific, and medical (ISM) bands. The proposed patch antenna with an ultra-compact size (5 × 5 × 0.26 mm3) was designed with 29% wide bandwidth (about 670 MHz). This wide bandwidth makes the antenna unaffected by implantation in different human body parts. The miniaturization process passed many steps by adding many slots with different shapes in the radiating element as well as in the ground plane. A 50 Ω coaxial feeding excites the antenna to maintain matching and low power loss. The specific absorption rate (SAR) was calculated for health considerations. The result was within the standard limits of IEEE organizations and the International Commission on Non-Ionizing Radiation Protection (ICNRP). The antenna was tested in tissues with multiple layers (up to seven layers) and at various depths (up to 29 mm). The link margin was calculated, and the proposed antenna enables 100 Kbps of data to be transferred over a distance of 20 m and approximately 1 Mbps over a distance of 7 m. The proposed antenna was fabricated and tested. The measured S11 parameters and the simulated results using the Computer Simulation Technology (CST Studio) simulator were in good agreement.
The objective of this paper is to develop a wearable circular UWB MIMO antenna array, consisting of four elements, that is capable of detecting and locating tumor cells within a heterogeneous breast phantom. The antenna element operates within a bandwidth from 2.4 GHz to 10.6 GHz when FR4 is used as the substrate, and extends from 2.57 GHz to 12.6 GHz when a Dacron fabric is used instead. The antenna is fabricated and measured, yielding highly similar results to the simulated outcomes. In the suggested detection system, one antenna is used for transmission, while the other antennas receive the transmitted signal. The employed antenna demonstrates gains of 5.49 dBi, 9.87 dBi, 11.9 dBi, and 14.7 dBi at resonant frequencies of 2.84 GHz, 3.87 GHz, 5.83 GHz, and 8.24 GHz, respectively, when a Dacron fabric is used as the substrate. Moreover, the proposed antenna exhibits a flexible shape with minimal vertical and horizontal bending effects across the entire operating frequency band. The antenna has a compact size of 42.85 × 42.85 mm2 and is printed on an FR4 substrate with a dielectric constant of 4.5 and a thickness of 1.6 mm for testing purposes. The S-parameters of the suggested system can effectively identify and precisely locate small tumors. Furthermore, the SAR findings indicate that the amount of power absorbed by the breast phantom tissues complies with the IEEE standards, thus confirming the suitability of the recommended antenna for the early detection and localization of breast cancer.
1 August 2022 in Journal of Electrical Engineering
Recently, graphene-patch antennas have been widely used in communication technology, especially in THz applications due to the extraordinary properties of graphene material. Herein, a graphene-based rectangular microstrip patch antenna is designed on an FR4 substrate material (ɛr = 4.3). A single and double-faced superstrate MTM is placed upon the radiating patch for di erent purposes, such as enhancing the overall antenna performance, protecting the patch from environmental jeopardies, and generating a multiband resonance frequency. A single face superstrate triangle SRR unit was used to produce a dual-band frequency at 3.5 and 4.331 THz. The S11 of the dual-band structure is achieved to be −26.78 dB and −46.25 dB with a bandwidth of 400 GHz and 460 GHz, respectively. The double face superstrate MTM unit cell of the triangle SRR printed on the opposite face gives another resonant frequency, so, triple frequency bands of 2.32, 3.35, and 4.38 THz with a wide impedance bandwidth of 230, 520, and 610 GHz, were generated, respectively. The double-face superstrate MTM not only enhances the antenna performance but also generates another resonant frequency that could be used in the next 6G communications. The proposed antenna is designed and optimized using two commercial 3D full-wave software, CST Microwave Studio and Ansoft HFSS, to validate the results.
This research presents a high-performance design for a multiple-input multiple-output (MIMO) antenna intended for operation within the 28 GHz band. The four-port MIMO antenna configuration, featuring 1 × 8 series-fed arrays for each port, has demonstrated peak gains of 15.5 dBi and bandwidths of 2 GHz. This improved antenna performance results from carefully optimized antenna spacing and a decoupling approach involving well-designed metamaterial cells, effectively minimizing interference between antenna elements. The system exhibits remarkably low mutual coupling, measuring below −40 dB, with envelope correlation coefficients of 0.00010, diversity gains nearing 10 dB, and a channel loss capacity of 0.11 bit/s/Hz across the frequency spectrum under investigation. Experimental evaluations have confirmed these improvements, establishing the proposed design as a robust candidate suitable for a wide range of millimeter-wave communication systems.