Joong-woo Shin

Dr. Joong-woo Shin

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
LHLEE HYEONGJIN
LEE HYEONGJIN
KYKwang-Hoon Yoon
Kwang-Hoon Yoon
JSJoong-woo Shin
Joong-woo Shin
JKJacChul Kim
JacChul Kim
Sungmin ChoSungmin Cho
Sungmin Cho
This paper proposes a method to improve the performance of a distribution system by optimizing volt–var function of a smart inverter to alleviate the voltage deviation problem due to distributed generation connection. In order to minimize voltage deviation and line losses which represent the performance of a distribution system, this paper proposes an algorithm that optimally sets the parameters of the volt–var function. In the process of optimizing the parameters of the volt–var function, the algorithm proposed in this paper considers minimizing the contribution of the reactive power in order not to affect the output of the distributed generation. In order to apply to the field, the distribution system in South Korea considering the configuration and operation regulation was selected as a test model for algorithm verification. As a result, the system performance was successfully improved by optimally setting the volt–var function of the smart inverter which is an effective way to solve the over-voltage problem caused by distributed generation connection. This paper verified the proposed method through OpenDSS, a quasi-static time-series simulation, for the test model considering the characteristics of the distribution system in South Korea.

5 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
KYKwang-Hoon Yoon
Kwang-Hoon Yoon
JSJoong-woo Shin
Joong-woo Shin
TNTea-Yang Nam
Tea-Yang Nam
JKJacChul Kim
JacChul Kim
WMWon-Sik Moon
Won-Sik Moon
The increasing use of photovoltaics (PVs) in distribution systems owing to the low-carbon policy has given rise to the need for various technological changes. In particular, the operation of on-load tap changers (OLTCs) has attracted attention. In traditional distribution systems, the OLTC operates via a line-drop compensator (LDC), which focuses on the load to solve the low-voltage problem; however, the problem of over-voltage caused by PVs persists. Currently, a method for operating an OLTC using the measured voltage is being researched; however, solving the voltage problem for several feeders connected to a main transformer (MT) is not viable. Therefore, this study proposes an OLTC operation method to address the feeder with the largest voltage problem depending on the direction of power flow. The proposed method selects a point where the OLTC operates using the difference between the measured and reference voltages. Setting the reference voltage can solve the problem that occurs due to the direction of power flow. Finally, the effectiveness of the proposed method is verified via case studies. Based on the results, we can conclude that the proposed method effectively solves the voltage problem, and an increase in hosting capacity can be expected.

30 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
JSJoong-woo Shin
Joong-woo Shin
KYKwang-Hoon Yoon
Kwang-Hoon Yoon
HCHui-Seok Chai
Hui-Seok Chai
JKJacChul Kim
JacChul Kim
In the power distribution system of South Korea, the sectionalizer minimizes and recovers the system from failures, and prohibits independent operation of distributed energy resources. Therefore, it is difficult to expect reliability improvements owing to a photovoltaic system in the power distribution system. Herein, we propose a reliability-centered maintenance-scheduling method based on an economic analysis of photovoltaic integration facilities to ensure the economic feasibility of the photovoltaic system operator and the reliability of the power distribution system. Photovoltaic integration facilities are divided into two categories based on their spread of the failure, and the maintenance scheduling is evaluated according to the maximum and minimum losses according to the time of failure. Facilities that cause power outages to photovoltaics and to loads have relatively little effect on the time of failure. This is because the effects of the power outages in the loads predominate. In contrast, facilities that only cause photovoltaic outages are affected by the generation time. In particular, insulated gate bipolar transistors that operate only during photovoltaic generation have been found to be more economical for corrective replacement than preventive replacement.

13 September 2023 in IEEE Access
Verified
Journal Article
Open access
TNTae-Yang Nam
Tae-Yang Nam
DCDong-Il Cho
Dong-Il Cho
WMWon-Sik Moon
Won-Sik Moon
JKJacChul Kim
JacChul Kim
JSJoong-woo Shin
Joong-woo Shin
A modular multilevel converter (MMC) synthesizes output voltages by combining voltages from various submodules (SMs) connected in series; thus, it is ideal for high-voltage transmission and distribution ranging from tens to several hundreds of kilovolts. However, MMCs incur high costs and losses, thus necessitating reliable operation. Research has been conducted to assess and enhance MMC reliability. Prior studies have presumed an exponential distribution for the reliability of SMs, including redundancy, thus implying that the failure rate does not change over time. This assumption signifies a constant system availability for the converter station, regardless of time, thus presenting a limitation in adequately comprehending the breakdown impact caused by a failure of the converter station. Additionally, as no standard exists for determining redundancy in medium-voltage direct current (MVDC) systems, a methodology is required to establish a redundancy criterion during the design process. Particularly for MVDC systems, the impact of power outages must be evaluated by considering the cost of expected outages based on system availability, as the load is interconnected. As a solution, we propose a method to assess the tradeoff between system availability and cost for an MVDC MMC, employing the Weibull distribution-based SM failure rate. The L-BFGS algorithm calculates the optimal value of the availability-cost function, and the number of redundant modules minimizing total operating cost is evaluated. Our case study determines the appropriate number of redundancy modules based on outage costs. The proposed methodology enables redundancy design that considers both reliability and operational costs, thus providing a practical solution to the problem of determining the number of redundant modules needed in MMCs.

8 March 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JSJoong-woo Shin
Joong-woo Shin
JKJacChul Kim
JacChul Kim
LHLEE HYEONGJIN
LEE HYEONGJIN
KYKwang-Hoon Yoon
Kwang-Hoon Yoon
HCHui-Seok Chai
Hui-Seok Chai
JKJin-Seok Kim
Jin-Seok Kim
Most industrial technologies are automated by sensitive electric parts such as programmable logic controllers(PLCs) and magnetic contactors which are required high power quality. The voltage sags occur in the non-faulted power distribution feeders during the fault duration. Therefore, voltage causes economic losses in the production process of various companies. To solve the fault current and the voltage sags, the superconducting fault current limiter (SFCL) is in the spotlight. The SFCL where was located on starting point of the feeder improves the reliability of the facility by reducing the fault current. In addition, it compensates the voltage sags on the bus-bar. In this paper, evaluating the voltage sags based on fault location in the power distribution system with the SFCL through PSCAD/EMTDC simulation. Next, the expected the voltage sags frequency is predicted by the reliability analysis technique of the power distribution system. The expected voltage sags frequency of the power distribution feeder is compared with before and after the application of the SFCL.

14 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
KYKwang-Hoon Yoon
Kwang-Hoon Yoon
JSJoong-woo Shin
Joong-woo Shin
JKJacChul Kim
JacChul Kim
LHLEE HYEONGJIN
LEE HYEONGJIN
JKJin-Seok Kim
Jin-Seok Kim
Owing to the increasing penetration level of distributed energy resources (DER) and direct current (DC) load, the usage of low-voltage direct current (LVDC) systems has expanded to achieve efficient operations. However, because the LVDC system reaches the peak fault current at a faster rate than the alternating current (AC) system, a solution that protects the system components is necessary to maintain system integrity. It is required by the low-voltage ride-through (LVRT) that the DERs maintain their interconnections with the LVDC system and support fault recovery. In this study, a method is proposed to allow the application of the superconducting fault current limiter (SFCL) to reduce the fault current and enhance the LVRT capability. However, when the DER maintain a connection to support fault recovery, the conventional resistive-type SFCL must withstand the burden of high-temperature superconducting (HTSC) operation during fault state dependence on LVRT. Therefore, this study proposes a trigger-type SFCL to reduce the burden of the HTSC element and enhance the LVRT capability. The voltage sag related to the LVRT was improved owing to the SFCL. The proposed solution was confirmed using PSCAD/EMTDC, which is a commercial software.