Eid Ammar

Dr. Eid Ammar


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Naji KharoufNaji Kharouf
Naji Kharouf
YAYouri Arntz
Youri Arntz
Eid AmmarEid Ammar
Eid Ammar
JZJihed ZGHAL
Jihed ZGHAL
Salvatore SauroSalvatore Sauro
Salvatore Sauro
Mancino DavideMancino Davide
Mancino Davide
The aim of this study was to compare the physicochemical properties, filling ability, and antibacterial activity of a premixed calcium silicate-based sealer to those of a powder–liquid bioceramic sealer. Ceraseal (CS) and BioRoot (BR) materials were analyzed using scanning electron microscopy and energy-dispersive X-ray spectroscopy at 7 and 14 d of immersion in distilled water. The filling ability of the two sealers as well as the water contact angle, solubility, flow, roughness, crystalline microstructure, pH, and compressive strength were also evaluated. The antibacterial activity was assessed through an agar diffusion as well as through direct tests. All the results were statistically analyzed using one-way or two-way analysis of variance tests. Statistically significant lower void percentages were observed for CS at 2 and 8 mm from the working length (WL) compared to those for the BR group, whilst no significant difference was observed at 5 mm from the WL. BR sealer showed higher alkaline pH, rougher surface, lower water contact angle values, lower flowability, and higher solubility compared to CS. BR showed globular and needle-like crystalline microstructure, whilst CS had globular and flower-like crystalline microstructure up to 72 h. No statistical difference was found for the compressive strength between the two sealers. BR and CS showed no antibacterial effect against Enterococcus faecalis after 3 h, whilst both sealers showed antibacterial capacity after 24 and 72 h. BR demonstrated higher antibacterial activity after 24 h. In conclusion, the use of bioceramic sealers may play an important role in controlling bacterial growth. Moreover, CS may have superior filling ability and lower solubility than the BioRoot sealer due to its specific chemical composition and mixing method.

25 February 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
Eid AmmarEid Ammar
Eid Ammar
Mancino DavideMancino Davide
Mancino Davide
MRMohammad Salem Rekab
Mohammad Salem Rekab
Youssef HaikelYoussef Haikel
Youssef Haikel
Naji KharoufNaji Kharouf
Naji Kharouf
The aim of this study was to investigate and compare, radiographically and clinically, the impacts of calcium-silicate based-cement (CSBC), nano-hydroxyapatite and platelet-rich fibrin (PRF) as pulpotomy agents in permanent immature molars with incomplete root development. Sixty-three participants (63 permanent immature molars) were included in this study. The patients were randomly divided into three equal groups. Fast setting MTA (MM-MTA), nano-hydroxyapatite and platelet-rich fibrin were used as pulpotomy agents. The teeth were evaluated clinically and radiographically after 6 and 12 months by two blinded examiners. Apical closure and pulp canal obliteration percentages were recorded. The in vitro reaction of the tested materials after a 7-day immersion period of the different materials in phosphate-buffered solution was analyzed using scanning electron microscopy to associate the in vitro mineralization with in vivo pulp canal obliteration percentages. Data were analyzed using Chi-square and ANOVA tests (α = 0.05). No significant difference was found between the three tested groups in terms of clinical and radiographic success (p > 0.05). All cases demonstrated evidence of root growth, including complete apical closure or continued apical closure. At 12 months, complete apical closure was found among the MM-MTA group (50%), nano-hydroxyapatite group (55%) and platelet-rich fibrin group (60%) (p > 0.05). After 12 months, pulp canal obliteration was more observed in the MM-MTA and nano-hydroxyapatite groups than in the PRF group (p < 0.05). MM-MTA (auto-mixed), NHA (hand-mixed) and PRF (autologous) could be used as pulpotomy agents since they exhibit comparable high clinical and radiographic success rates. However, the fact that the groups managed with MM-MTA and NHA have a higher tendency to canal obliteration might indicate that PRF should be considered the first choice material as pulpotomy agent, as it would make retreatment considerably easier.

16 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Naji KharoufNaji Kharouf
Naji Kharouf
TATarek Ashi
Tarek Ashi
Eid AmmarEid Ammar
Eid Ammar
Levi MaguinaLevi Maguina
Levi Maguina
JZJihed ZGHAL
Jihed ZGHAL
Mancino DavideMancino Davide
Mancino Davide
(1) Background: This study investigated the effect of the adhesive layer thickness and the length of resin tags on dentin bond strength of five universal adhesives applied in self-etch mode. (2) Methods: One hundred and fifty extracted human third molars were used. Five different universal adhesives were applied in self-etch mode on the dentin surface. Half of the specimens were subjected to an aging procedure for six months. A shear bond strength (SBS) test was performed and the results were statistically analyzed with a t-test and one-way ANOVA test. Scanning electron microscopy (SEM) was executed to measure the adhesive layer thickness and tag depth. (3) Results: No statistical differences were found between the five adhesive systems after a 24 h storage period, regardless of layer thickness and tag depth (p < 0.05). After 6 months of aging in water at 37 °C, Iperbond Max and Scotchbond Universal preserved the bond strength over time (p < 0.05), whilst the SBS of Iperbond Ultra, FuturaBond M+, and Ibond Universal decreased significantly after the aging period. No relation was observed between the adhesive thickness or tags’ length on SBS. (4) Conclusions: Within the limitation of this study, the stability over time of the bond strength of universal adhesives depends on their compositions regardless of the adhesive layer thickness and/or tags’ length.

16 March 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Rim BourgiRim Bourgi
Rim Bourgi
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
Monika Lukomska-SzymanskaMonika Lukomska-Szymanska
Monika Lukomska-Szymanska
ECElizabeth Cornejo-Ríos
Elizabeth Cornejo-Ríos
Youssef HaikelYoussef Haikel
Youssef Haikel
Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants are used; however, no sole disinfectant can be designated as universal for all the impression materials. Thus, the aim of this study is to systemically review the literature to evaluate the effect of the existing disinfection procedures on the bacterial colonization of dental impression materials. This systematic review and meta-analysis was conducted according to the PRISMA statement. PubMed (MEDLINE), Web of Science, Scopus, EMBASE, and SciELO databases were screened up to April 2021. Eligibility criteria included in vitro studies reporting the antibacterial activity of disinfectant solutions in dental impression materials. The meta-analysis was performed using Review Manager (version 5.3.5). A global comparison was performed with the standardized mean difference based on random-effect models at a significance level of α = 0.05. A total of seven studies were included in the meta-analysis. The included studies described the effect of disinfection processes with chlorhexidine gluconate, alcohol, sodium hypochlorite, glutaraldehyde, and hydrogen peroxide in alginate, polyvinyl siloxane, and polyether impression materials. The meta-analyses showed that the use of chlorhexidine, alcohol, glutaraldehyde, and sodium hypochlorite reduced the colony-forming units by a milliliter (CFU/mL) in alginate (p < 0.001). On the other hand, glutaraldehyde, sodium hypochlorite, and alcohol reduced the CFU/mL in polyvinyl siloxane (p < 0.001). Finally, alcohol and glutaraldehyde reduced the CFU/mL in polyether material (p < 0.001). High heterogenicity was observed for the alginate and polyvinyl siloxane materials (I2 = 74%; I2 = 90%). Based on these in vitro studies, the disinfection of impression materials with several disinfection agents reduces the CFU/mL count.

18 May 2022 in Gels
Verified
Journal Article
Open access
PDF file
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Mancino DavideMancino Davide
Mancino Davide
Rim BourgiRim Bourgi
Rim Bourgi
AAAlejandra Alvarado-Orozco
Alejandra Alvarado-Orozco
LRLaura Emma Rodríguez-Vilchis
Laura Emma Rodríguez-Vilchis
Naji KharoufNaji Kharouf
Naji Kharouf
Since the adhesion of resin composites to calcium silicate-based cement is considered challenging. Therefore, the best adhesion strategy should be indicated. This review aimed to assess the effect of different adhesive systems on the bond strength of resin composite to calcium silicate-based cement through a systematic review and meta-analysis. The subsequent PICOS framework used was: population, calcium silicate-based cement; intervention, use of self-etch adhesive systems; control, use of total-etch adhesive systems; outcome, bond strength; study design, in vitro studies. The literature search was conducted independently by two reviewers up to 18 February 2021. Electronic databases (PubMed, ISI Web of Science, SciELO, Scopus, and Embase) were searched for applicable articles. In vitro manuscripts studying the effect of adhesive systems on the bond strength of calcium silicate-based cement were considered. The meta-analyses were performed using Review Manager Software version 5.3.5 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). Bond strength comparisons were made considering the type of calcium silicate-based cement (Mineral Trioxide Aggregate (MTA), Biodentine™, or TheraCal LC®). A p-value < 0.05 was considered statistically significant. A total of 7321 studies were retrieved in databases searched. After full-text evaluation, 37 eligible papers were assessed for qualitative analysis, leaving a total of 22 papers for the quantitative analysis. According to the meta-analysis, the bond strength values of resin composite materials to MTA and TheraCal LC® cement were favored when a total-etch adhesive system was used (p ≤ 0.02). On the other hand, the meta-analysis of the bond strength of resin-based materials to Biodentine™ calcium silicate-based cement was similar between both approaches (p = 0.12). The in vitro evidence suggests that the bond strength of resin-based materials to both MTA and TheraCal LC® cement was preferred by using the total-etch adhesive strategy. However, when bonding to Biodentine™, the use of self-etch or total-etch strategies displayed promising results. Given the lack of evidence related to the chemical interaction of self-etch adhesive materials with the bioceramics, if self-etch adhesives are used for bonding resin-based restorations to calcium silicate-based cement, a pretreatment with phosphoric acid could be recommended.

Verified
Journal Article
Open access
PDF file
Naji KharoufNaji Kharouf
Naji Kharouf
Salvatore SauroSalvatore Sauro
Salvatore Sauro
Eid AmmarEid Ammar
Eid Ammar
JZJihed ZGHAL
Jihed ZGHAL
HJHamdi Jmal
Hamdi Jmal
Mancino DavideMancino Davide
Mancino Davide
The aim of the present in vitro study was to evaluate specific mechanical and physicochemical properties of two calcium silicate based sealers, (AH Plus Bioceramic “AHPB”; Well-Root ST “WRST”), and a conventional resin sealer (AH Plus “AHP”). These aims were accomplished by assessing the porosity, pH, compression strength, roughness, wettability and cell attachment of the tested materials. The results were compared statistically using the one-way ANOVA test. Higher pH values were obtained in both AHPB and WRST compared to AHP at 3, 24 and 72 h (p < 0.05). A greater level of porosity and wettability was detected for both AHPB and WRST compared to the resin sealer AHP (p < 0.05). Evident cell growth characterized by elongated morphology was observed on the surface of AHPB and WRST, while only a thin layer of cells was seen on the surface of AHP. A significant lower compression strength and modulus were obtained in the specimens created using AHPB compared to those made with AHP and WRST (p < 0.05). The removal of calcium silicates may be quite tricky during endodontic retreatment. In conclusion, considering the limitations of the present in vitro study, both calcium silicate sealers demonstrated good physicochemical properties. However, the lower compression strength and modulus of AHPB may facilitate its removal and make the retreatment procedures considerably easier.