Laser scanning 3D imaging technology, because it can obtain accurate three-dimensional surface data, has been widely used in the search for wrecks and rescue operations, underwater resource development, and other fields. At present, the conventional underwater spinning laser scanning imaging system maintains a relatively fixed light window. However, in low-light situations underwater, the rotation of the scanning device causes some degree of water fluctuation, which warps the light strip data that the system sensor receives about the object’s surface. To solve this problem, this research studies an underwater 3D scanning and imaging system that makes use of a fixed light window and a spinning laser (FWLS). A refraction error compensation algorithm is investigated that is based on the fundamentals of linear laser scanning imaging, and a dynamic refraction mathematical model is established based on the motion of the imaging device. The results of the experiment on error analysis in an optimal underwater environment indicate that the error in reconstructing the radius is decreased by 60% (from 2.5 mm to around 1 mm) when compensating for the measurement data of a standard sphere with a radius of 20 mm. Moreover, the compensated point cloud data exhibit a higher degree of correspondence with the model of the standard spherical point cloud. Furthermore, we examine the impact of physical noise, measurement distance, and partial occlusion of the object on the imaging system inside an authentic underwater setting. This study is a good starting point for looking at the refractive error of an underwater laser scanning imaging system. It also provides to us some ideas for future research on the refractive error of other scanning imaging methods.
Axial piston pumps provide a number of benefits, including strong pressure resistance, high efficiency, high transmission power, a broad speed range, and a long lifespan. These characteristics have led to their widespread usage in naval applications, construction machines, and hydraulic machinery. On the other hand, axial piston pumps frequently display reduced operating speeds as well as instability because of their inherently nonlinear properties. In this study, a mathematical model of these changeable (variable) processes is developed using a mix of theoretical calculations and acquired data. An investigation of variable mechanism control in axial piston pumps is carried out centered on robust control methods, and the controller is constructed utilizing robust H∞ theory. In terms of resilience, control precision, and system reaction time, simulations show that the H controller surpasses the PID controller.
The collapse of cavitation bubbles in a hydraulic system generates localized zones of high temperature and pressure and, under certain conditions, luminescence. In this study, we studied the influence of the hydraulic oil viscosity on cavitation luminescence. We used a hydraulic cone-type throttle valve with antiwear hydraulic oils with kinematic viscosities of 32, 46, and 46 mm2/s at 40°C. Computational fluid dynamics was used to simulate the flow field of the cone-throttle valve under different viscosities. After constructing the visual experimental platform of hydraulic cavitation, we observed cavitation luminescence of the valve under three different hydraulic oil conditions. After the experiment, the viscosity index of the oil increased, the pour point decreased, and the flash point decreased. Thus, the viscosity–temperature characteristics and low-temperature fluidity improved and the safety decreased after luminescence.
In this paper, a microheater that can absorb thermal stress and has a large heating area is demonstrated by optimizing the structure and process of the microheater. Four symmetrically distributed elongated support beam structures were machined around the microheater via deep silicon etching. This design efficiently mitigates the deformation of the heated region caused by thermal expansion and enhances the structural stability of the microheater. The updated microheater no longer converts the work area into a thin film; instead, it creates a stable heating platform that can uniformly heat a work area measuring 10 × 10 mm2. The microheater is verified to have high temperature uniformity and structural stability in finite element simulation. Finally, thorough investigations of electrical–thermal–structural characterization were conducted. The test findings show that the new microheater can achieve 350 °C with a power consumption of 6 W and a thermal reaction time of 22 s. A scan of its whole plane reveals that the surface of the working area of the new microheater is flat and does not distort in response to variations in temperature, offering good structural stability.
23 May 2021 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Cavitation is common in electrohydraulic servo valves and often adversely affects their performance. This study explores the influence of pre-stage cavitation on the performance of double-nozzle flapper pressure servo valves. The mechanism of cavitation is theoretically studied, a dynamic model of cavitation bubble motion is deduced, and the main factors affecting the development and variation of cavitation are determined. The software ADINA is used to establish a servo valve pre-stage fluid–structure interaction (FSI) model using the finite volume method. Cavitation is introduced to the model to conduct an FSI simulation of the influence of pre-stage cavitation on the performance of double-nozzle flapper pressure servo valves with nozzle diameters of 0.5, 0.55, 0.6, and 0.7 mm. An experiment on the servo valve is carried out to verify the simulation results. The simulation and experiment show that a nozzle diameter that is too small or large weakens the performance of a servo valve, and 0.6 mm is an ideal diameter; asymmetric double nozzles may reduce or improve the performance of a servo valve, and a combination of 0.6 and 0.55 mm nozzles is optimal; pre-stage cavitation influences the performance of a servo valve by changing the size and pressure gain of the dead zone; and excessive cavitation strength decreases or increases the dead zone and increases the pressure gain.