Yuhang Wang

Yuhang Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
景张景辉 张
景辉 张
YWYuhang Wang
Yuhang Wang
TZTao Zhang
Tao Zhang
KYKai Yang
Kai Yang
JZJian Zhang
Jian Zhang
XWXinyu Wang
Xinyu Wang
Laser scanning 3D imaging technology, because it can obtain accurate three-dimensional surface data, has been widely used in the search for wrecks and rescue operations, underwater resource development, and other fields. At present, the conventional underwater spinning laser scanning imaging system maintains a relatively fixed light window. However, in low-light situations underwater, the rotation of the scanning device causes some degree of water fluctuation, which warps the light strip data that the system sensor receives about the object’s surface. To solve this problem, this research studies an underwater 3D scanning and imaging system that makes use of a fixed light window and a spinning laser (FWLS). A refraction error compensation algorithm is investigated that is based on the fundamentals of linear laser scanning imaging, and a dynamic refraction mathematical model is established based on the motion of the imaging device. The results of the experiment on error analysis in an optimal underwater environment indicate that the error in reconstructing the radius is decreased by 60% (from 2.5 mm to around 1 mm) when compensating for the measurement data of a standard sphere with a radius of 20 mm. Moreover, the compensated point cloud data exhibit a higher degree of correspondence with the model of the standard spherical point cloud. Furthermore, we examine the impact of physical noise, measurement distance, and partial occlusion of the object on the imaging system inside an authentic underwater setting. This study is a good starting point for looking at the refractive error of an underwater laser scanning imaging system. It also provides to us some ideas for future research on the refractive error of other scanning imaging methods.

26 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YFYuan Feng
Yuan Feng
JZJian Zhang
Jian Zhang
JLJiayang Li
Jiayang Li
TZTao Zhang
Tao Zhang
YWYuhang Wang
Yuhang Wang
JXJingwei Xue
Jingwei Xue
Axial piston pumps provide a number of benefits, including strong pressure resistance, high efficiency, high transmission power, a broad speed range, and a long lifespan. These characteristics have led to their widespread usage in naval applications, construction machines, and hydraulic machinery. On the other hand, axial piston pumps frequently display reduced operating speeds as well as instability because of their inherently nonlinear properties. In this study, a mathematical model of these changeable (variable) processes is developed using a mix of theoretical calculations and acquired data. An investigation of variable mechanism control in axial piston pumps is carried out centered on robust control methods, and the controller is constructed utilizing robust H∞ theory. In terms of resilience, control precision, and system reaction time, simulations show that the H controller surpasses the PID controller.

21 September 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
TZTao Zhang
Tao Zhang
XLxiong liuguang
xiong liuguang
ZPZequan Pan
Zequan Pan
CZChunhua Zhang
Chunhua Zhang
WQWen Qu
Wen Qu
CYChunmei Yang
Chunmei Yang
This study presents a newly developed piezoelectric drive mechanism for the purpose of designing, analyzing, and testing a micro-positioning platform driven by piezoelectric actuators. The platform incorporates a piezoelectric ceramic actuator and a flexible hinge drive and features a symmetrical two-stage lever (STSL) amplification mechanism and a parallelogram output structure. The implementation of this design has led to notable enhancements in the dynamic properties of the platform, thereby eliminating the undesired parasitic displacement of the mechanism. An analytical model describing the fully elastic deformation of the platform is established, which is further verified by finite element simulation. Finally, the static and dynamic performances of the platform are comprehensively evaluated through experiments. A closed-loop control strategy is adopted to eliminate the nonlinear hysteresis phenomenon of the piezoceramic actuator (PEA). The experimental results show that the piezoelectric micro-actuator platform has a motion range of 97.84 μm × 98.03 μm; the output coupling displacement error is less than 1%; the resolutions of the two axes are 8.1 nm and 8 nm, respectively; and the x-axis and y-axis trajectory tracking errors are both 0.6%. The piezoelectric micromotion platform has good dynamic properties, precision, and stability. The design has a wide application potential in the field of micro-positioning.

12 January 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
TZTao Zhang
Tao Zhang
ZPZequan Pan
Zequan Pan
CZChunhua Zhang
Chunhua Zhang
XLxiong liuguang
xiong liuguang
CYChunmei Yang
Chunmei Yang
WQWen Qu
Wen Qu
In this paper, a microheater that can absorb thermal stress and has a large heating area is demonstrated by optimizing the structure and process of the microheater. Four symmetrically distributed elongated support beam structures were machined around the microheater via deep silicon etching. This design efficiently mitigates the deformation of the heated region caused by thermal expansion and enhances the structural stability of the microheater. The updated microheater no longer converts the work area into a thin film; instead, it creates a stable heating platform that can uniformly heat a work area measuring 10 × 10 mm2. The microheater is verified to have high temperature uniformity and structural stability in finite element simulation. Finally, thorough investigations of electrical–thermal–structural characterization were conducted. The test findings show that the new microheater can achieve 350 °C with a power consumption of 6 W and a thermal reaction time of 22 s. A scan of its whole plane reveals that the surface of the working area of the new microheater is flat and does not distort in response to variations in temperature, offering good structural stability.

22 September 2023 in Processes
Verified
Journal Article
Open access
PDF file
JZJian Zhang
Jian Zhang
JFJifeng Fu
Jifeng Fu
XZXinyang Zhang
Xinyang Zhang
TZTao Zhang
Tao Zhang
YWYuhang Wang
Yuhang Wang
A hydraulic cavitation platform was developed in order to examine the occurrence of cavitation in the rectangular throttling groove spool and its correlation with noise characteristics. The test valve is constructed using PMMA material, which possesses excellent transparency. This transparency enables direct visual examination of cavitation occurring at the throttle slot. Additionally, high-speed photography is employed to observe the flow characteristics of the valve port, facilitating the analysis of cavitation morphology changes. Furthermore, a noise meter is utilized to measure and record the noise level and its corresponding spectrum. The flow field and flow phenomena at the rectangular throttling groove spool were studied using high-speed photography, noise spectrum analysis, and other methods. It is discovered that back pressure has the greatest influence on cavitation and flow separation, followed by the influence of intake pressure on cavitation morphology and noise. As the back pressure lowers, the cavitation morphology changes from flaky to cloudy, and the cavitation intensity, distribution area, and noise level increase. Background noise and cavitation noise have distinct frequency differences; cavitation noise in the rectangular throttling groove spool is high-frequency noise, with a frequency of more than 8 kHz, and the higher the frequency, the greater the difference in noise value. The magnitude of the alterations in noise intensity is minimal. The noise values exhibit slight variations of 2.3 dB, 4 dB, and 4.3 dB under varying back pressure circumstances of 3 MPa, 4 MPa, and 5 MPa inlet pressure, respectively. It is recommended to use the frequency of cavitation noise to detect the cavitation state and monitor the cavitation process. In the low-frequency region, the cavitation noise in the rectangular throttle groove valve core is not significantly different. Once the center frequency surpasses 3.15 kHz, a discernible distinction emerges, with the magnitude of the discrepancy in noise value increasing as the frequency rises. In other words, the cavitation cloud does not pulsate at one single frequency, but rather in a range of relatively high frequencies (more than 3.15 kHz).

25 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ZAZeyu An
Zeyu An
XFXiaoyue Fan
Xiaoyue Fan
YWYuhang Wang
Yuhang Wang
TZTao Zhang
Tao Zhang
In the electromagnetic detection of shallow subsurface metal snaring traps in forested areas, conventional transmission schemes such as square waves, PRBS and PSO waveforms inevitably excite severe clutter in soils exhibiting viscous remanent magnetization (VRM), which drastically degrades the signal-to-clutter ratio (SCR). To resolve this issue, this paper proposes a spectrum modification method for the transmitting scheme based on an Interval Robust hybrid RIME and Sequential Quadratic Programming (IR-RIME-SQP) algorithm. By coupling the Debye relaxation characteristics of ferromagnetic targets with the soil VRM model, the proposed method concentrates limited transmission energy into a bell-shaped frequency window near the target’s characteristic frequency. Furthermore, interval analysis is introduced to ensure robust performance against the dynamic drift of coil parameters. The feasibility of this novel transmitting scheme is validated through ablation experiments and comparative simulations. Finally, laboratory measurements demonstrate that IR-RIME-SQP provides a more rational and efficient energy allocation strategy, improving the targeted frequency energy retention (TFER) by approximately 16.4% and thereby enhancing both detection efficiency and precision.