Matthias F. Frölich

Dr. Matthias F. Frölich

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2020 in Cancers
Verified
Journal Article
Open access
PDF file
PWPiotr Woznicki
Piotr Woznicki
NWNiklas Westhoff
Niklas Westhoff
THThomas Huber
Thomas Huber
PRPhilipp Riffel
Philipp Riffel
MFMatthias F. Frölich
Matthias F. Frölich
DNDominik Nörenberg
Dominik Nörenberg
Radiomics is an emerging field of image analysis with potential applications in patient risk stratification. This study developed and evaluated machine learning models using quantitative radiomic features extracted from multiparametric magnetic resonance imaging (mpMRI) to detect and classify prostate cancer (PCa). In total, 191 patients that underwent prostatic mpMRI and combined targeted and systematic fusion biopsy were retrospectively included. Segmentations of the whole prostate glands and index lesions were performed manually in apparent diffusion coefficient (ADC) maps and T2-weighted MRI. Radiomic features were extracted from regions corresponding to the whole prostate gland and index lesion. The best performing combination of feature setup and classifier was selected to compare its predictive ability of the radiologist’s evaluation (PI-RADS), mean ADC, prostate specific antigen density (PSAD) and digital rectal examination (DRE) using receiver operating characteristic (ROC) analysis. Models were evaluated using repeated 5-fold cross-validation and a separate independent test cohort. In the test cohort, an ensemble model combining a radiomics model, with models for PI-RADS, PSAD and DRE achieved high predictive AUCs for the differentiation of (i) malignant from benign prostatic lesions (AUC = 0.889) and of (ii) clinically significant (csPCa) from clinically insignificant PCa (cisPCa) (AUC = 0.844). Our combined model was numerically superior to PI-RADS for cancer detection (AUC = 0.779; p = 0.054) as well as for clinical significance prediction (AUC = 0.688; p = 0.209) and showed a significantly better performance compared to mADC for csPCa prediction (AUC = 0.571; p = 0.022). In our study, radiomics accurately characterizes prostatic index lesions and shows performance comparable to radiologists for PCa characterization. Quantitative image data represent a potential biomarker, which, when combined with PI-RADS, PSAD and DRE, predicts csPCa more accurately than mADC. Prognostic machine learning models could assist in csPCa detection and patient selection for MRI-guided biopsy.

11 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MSMartin Soschynski
Martin Soschynski
FHFlorian Hagen
Florian Hagen
SBStefan Baumann
Stefan Baumann
MHMuhammad Taha Hagar
Muhammad Taha Hagar
JWJakob Weiss
Jakob Weiss
PKPatrick Krumm
Patrick Krumm
The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0–2965 (interquartile range (IQR) 0–135). The IQ was very good (one, IQR one–two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

21 February 2023 in European Radiology
Verified
Journal Article
Open access
PDF file
AHAlexander Hertel
Alexander Hertel
HTHishan Tharmaseelan
Hishan Tharmaseelan
LRLukas T. Rotkopf
Lukas T. Rotkopf
DNDominik Nörenberg
Dominik Nörenberg
PRPhilipp Riffel
Philipp Riffel
IAIsabelle Ayx
Isabelle Ayx
Objectives: Radiomics image data analysis offers promising approaches in research but has not been implemented in clinical practice yet, partly due to the instability of many parameters. The aim of this study is to evaluate the stability of radiomics analysis on phantom scans with photon-counting detector CT (PCCT). Methods: Photon-counting CT scans of organic phantoms consisting of 4 apples, kiwis, limes, and onions each were performed at 10 mAs, 50 mAs, and 100 mAs with 120-kV tube current. The phantoms were segmented semi-automatically and original radiomics parameters were extracted. This was followed by statistical analysis including concordance correlation coefficients (CCC), intraclass correlation coefficients (ICC), as well as random forest (RF) analysis, and cluster analysis to determine the stable and important parameters. Results: Seventy-three of the 104 (70%) extracted features showed excellent stability with a CCC value > 0.9 when compared in a test and retest analysis, and 68 features (65.4%) were stable compared to the original in a rescan after repositioning. Between the test scans with different mAs values, 78 (75%) features were rated with excellent stability. Eight radiomics features were identified that had an ICC value greater than 0.75 in at least 3 of 4 groups when comparing the different phantoms in a phantom group. In addition, the RF analysis identified many features that are important for distinguishing the phantom groups. Conclusion: Radiomics analysis using PCCT data provides high feature stability on organic phantoms, which may facilitate the implementation of radiomics analysis likewise in clinical routine. Key Points: • Radiomics analysis using photon-counting computed tomography provides high feature stability. • Photon-counting computed tomography may pave the way for implementation of radiomics analysis in clinical routine.

15 November 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HTHishan Tharmaseelan
Hishan Tharmaseelan
LRLukas T. Rotkopf
Lukas T. Rotkopf
IAIsabelle Ayx
Isabelle Ayx
AHAlexander Hertel
Alexander Hertel
DNDominik Nörenberg
Dominik Nörenberg
MFMatthias F. Frölich
Matthias F. Frölich
Feature stability and standardization remain challenges that impede the clinical implementation of radiomics. This study investigates the potential of spectral reconstructions from photon-counting computed tomography (PCCT) regarding organ-specific radiomics feature stability. Abdominal portal-venous phase PCCT scans of 10 patients in virtual monoenergetic (VM) (keV 40–120 in steps of 10), polyenergetic, virtual non-contrast (VNC), and iodine maps were acquired. Two 2D and 3D segmentations measuring 1 and 2 cm in diameter of the liver, lung, spleen, psoas muscle, subcutaneous fat, and air were obtained for spectral reconstructions. Radiomics features were extracted with pyradiomics. The calculation of feature-specific intraclass correlation coefficients (ICC) was performed by comparing all segmentation approaches and organs. Feature-wise and organ-wise correlations were evaluated. Segmentation-resegmentation stability was evaluated by concordance correlation coefficient (CCC). Compared to non-VM, VM-reconstruction features tended to be more stable. For VM reconstructions, 3D 2 cm segmentation showed the highest average ICC with 0.63. Based on a criterion of ≥ 3 stable organs and an ICC of ≥ 0.75, 12—mainly non-first-order features—are shown to be stable between the VM reconstructions. In a segmentation-resegmentation analysis in 3D 2 cm, three features were identified as stable based on a CCC of > 0.6 in ≥ 3 organs in ≥ 6 VM reconstructions. Certain radiomics features vary between monoenergetic reconstructions and depend on the ROI size. Feature stability was also shown to differ between different organs. Yet, glcm_JointEntropy, gldm_GrayLevelNonUniformity, and firstorder_Entropy could be identified as features that could be interpreted as energy-independent and segmentation-resegmentation stable in this PCCT collective. PCCT may support radiomics feature standardization and comparability between sites.

1 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Daniel DillingerDaniel Dillinger
Daniel Dillinger
DODaniel Overhoff
Daniel Overhoff
CBChristian Booz
Christian Booz
HKHanns Leonhard Kaatsch
Hanns Leonhard Kaatsch
JPJoel Piechotka
Joel Piechotka
SWStephan Waldeck
Stephan Waldeck
Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. Results: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. Conclusions: Our data suggest that VMI at 60–70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.

5 October 2023 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
HTHishan Tharmaseelan
Hishan Tharmaseelan
AVAbhinay K. Vellala
Abhinay K. Vellala
AHAlexander Hertel
Alexander Hertel
FTFabian Tollens
Fabian Tollens
LRLukas T. Rotkopf
Lukas T. Rotkopf
MFMatthias F. Frölich
Matthias F. Frölich
Objectives: The goal of this study is to demonstrate the performance of radiomics and CNN-based classifiers in determining the primary origin of gastrointestinal liver metastases for visually indistinguishable lesions. Methods: In this retrospective, IRB-approved study, 31 pancreatic cancer patients with 861 lesions (median age [IQR]: 65.39 [56.87, 75.08], 48.4% male) and 47 colorectal cancer patients with 435 lesions (median age [IQR]: 65.79 [56.99, 74.62], 63.8% male) were enrolled. A pretrained nnU-Net performed automated segmentation of 1296 liver lesions. Radiomics features for each lesion were extracted using pyradiomics. The performance of several radiomics-based machine-learning classifiers was investigated for the lesions and compared to an image-based deep-learning approach using a DenseNet-121. The performance was evaluated by AUC/ROC analysis. Results: The radiomics-based K-nearest neighbor classifier showed the best performance on an independent test set with AUC values of 0.87 and an accuracy of 0.67. In comparison, the image-based DenseNet-121-classifier reached an AUC of 0.80 and an accuracy of 0.83. Conclusions: CT-based radiomics and deep learning can distinguish the etiology of liver metastases from gastrointestinal primary tumors. Compared to deep learning, radiomics based models showed a varying generalizability in distinguishing liver metastases from colorectal cancer and pancreatic adenocarcinoma.