Yu-Ting Kao

Ms. Yu-Ting Kao

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
YKYu-Ting Kao
Yu-Ting Kao
TKTomasz S. Kaminski
Tomasz S. Kaminski
WPWitold Postek
Witold Postek
JGJan Guzowski
Jan Guzowski
KMKarol Makuch
Karol Makuch
PGPiotr Garstecki
Piotr Garstecki
Easy-to-use gravity-driven step emulsification devices are capable of digital enumeration of bacteria and antibiotic susceptibility testing within 5 hours.

12 April 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
YKYu-Ting Kao
Yu-Ting Kao
SCSilvia Calabrese
Silvia Calabrese
NBNadine Borst
Nadine Borst
MLMichael Lehnert
Michael Lehnert
YLYu-Kai Lai
Yu-Kai Lai
FSFelix von Stetten
Felix von Stetten
We demonstrate detection and quantification of bacterial load with a novel microfluidic one-pot wash-free fluorescence in situ hybridization (FISH) assay in droplets. The method offers minimal manual workload by only requiring mixing of the sample with reagents and loading it into a microfluidic cartridge. By centrifugal microfluidic step emulsification, our method partitioned the sample into 210 pL (73 µm in diameter) droplets for bacterial encapsulation followed by in situ permeabilization, hybridization, and signal detection. Employing locked nucleic acid (LNA)/DNA molecular beacons (LNA/DNA MBs) and NaCl-urea based hybridization buffer, the assay was characterized with Escherichia coli, Klebsiella pneumonia, and Proteus mirabilis. The assay performed with single-cell sensitivity, a 4-log dynamic range from a lower limit of quantification (LLOQ) at ~3 × 103 bacteria/mL to an upper limit of quantification (ULOQ) at ~3 × 107 bacteria/mL, anda linearity R2 = 0.976. The total time-to-results for detection and quantification was around 1.5 hours.

3 May 2023 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
YLYu-Kai Lai
Yu-Kai Lai
YKYu-Ting Kao
Yu-Ting Kao
JHJacob Friedrich Hess
Jacob Friedrich Hess
SCSilvia Calabrese
Silvia Calabrese
FSFelix von Stetten
Felix von Stetten
NPNils Paust
Nils Paust
We present a centrifugal microfluidic cartridge for the eight-fold parallel generation of monodisperse water-in-oil droplets using standard laboratory equipment. The key element is interfacing centrifugal microfluidics with its design based on polar coordinates to the linear structures of standard high-throughput laboratory automation. Centrifugal step emulsification is used to simultaneously generate droplets from eight samples directly into standard 200 μl PCR 8-tube strips. To ensure minimal manual liquid handling, the design of the inlets allows the user to load the samples and the oil via a standard multichannel pipette. Simulation-based design of the cartridge ensures that the performance is consistent in each droplet generation unit despite the varying radial positions that originate from the interface to the linear oriented PCR 8-tube strip and from the integration of linear oriented inlet holes for the multichannel pipettes. Within 10 minutes, sample volumes of 50 μl per droplet generation unit are emulsified at a fixed rotation speed of 960 rpm into 1.47 × 105 monodisperse droplets with a mean diameter of 86 μm. The overall coefficient of variation (CV) of the droplet diameter was below 4%. Feasibility is demonstrated by an exemplary digital droplet polymerase chain reaction (ddPCR) assay which showed high linearity (R2 ≥ 0.999) across all of the eight tubes of the strip.