Nurcan Kılıç Baygutalp

Prof. Nurcan Kılıç Baygutalp

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2023 in Environmental Chemistry Letters
Verified
Journal Article
Closed access
PDF file
MCMeltem Cetin
Meltem Cetin
FMFatma Demirkaya Miloglu
Fatma Demirkaya Miloglu
NBNurcan Kılıç Baygutalp
Nurcan Kılıç Baygutalp
OCOnur Ceylan
Onur Ceylan
SYSerkan Yildirim
Serkan Yildirim
HGHalise İnCi Gul
Halise İnCi Gul

18 July 2023 in Biological Trace Element Research
Verified
Journal Article
Closed access
PDF file
ÖÇözgür çelebi
özgür çelebi
DÇDemet Çelebi
Demet Çelebi
SBSumeyye Baser
Sumeyye Baser
EAElif Aydın
Elif Aydın
ERErva Rakıcı
Erva Rakıcı
A. M. Abd El-AtyA. M. Abd El-Aty
A. M. Abd El-Aty

20 October 2022 in Nutrients
Verified
Journal Article
Open access
PDF file
MOMurat Ozan
Murat Ozan
YBYusuf Buzdagli
Yusuf Buzdagli
CEMRE DIDEM IyipınarCEMRE DIDEM Iyipınar
CEMRE DIDEM Iyipınar
NBNurcan Kılıç Baygutalp
Nurcan Kılıç Baygutalp
NYNeslihan Yüce
Neslihan Yüce
FBFatih Baygutalp
Fatih Baygutalp
In previous studies, the effect of single or combined intake of caffeine (CAF) and taurine (TAU) on exercise performance was investigated. However, the potential synergistic effect on physical and cognitive performance after fatigue induced by anaerobic exercise is unknown. The effects of single and combination CAF and TAU supplementation on the Wingate test in elite male boxers and to evaluate balance, agility and cognitive performance after fatigue are being investigated for the first time in this study. Twenty elite male boxers 22.14 ± 1.42 years old were divided into four groups in this double-blind, randomized crossover study: CAF (6 mg/kg of caffeine), TAU (3 g single dose of taurine), CAF*TAU (co-ingestion of 3 g single dose of taurine and 6 mg/kg of caffeine) and PLA (300 mg maltodextrin). The findings are as follows: co-ingestion of CAF*TAU, improved peak (W/kg), average (W), minimum (W) power, time to reach (s), and RPE performances compared to the PLA group significantly (p < 0.05). Similarly, it was determined that a single dose of TAU, created a significant difference (p < 0.05) in peak power (W/kg), and average and minimum power (W) values compared to the CAF group. According to the balance and agility tests performed after the Wingate test, co-ingestion of CAF*TAU revealed a significant difference (p < 0.05) compared to the PLA group. In terms of cognitive performance, co-ingestion of CAF*TAU significantly improved the neutral reaction time (ms) compared to the TAU, CAF and PLA groups. As a result, elite male boxers performed better in terms of agility, balance and cognitive function when they consumed a combination of 6 mg/kg CAF and 3 g TAU. It has been determined that the combined use of these supplements is more effective than their single use.

22 November 2021 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
FBFatih Baygutalp
Fatih Baygutalp
YBYusuf Buzdagli
Yusuf Buzdagli
MOMurat Ozan
Murat Ozan
MKMitat KOZ
Mitat KOZ
NBNurcan Kılıç Baygutalp
Nurcan Kılıç Baygutalp
Gökhan ATASEVERGökhan ATASEVER
Gökhan ATASEVER
Background: This study aims to determine and compare the effects of exercise modalities with different intensities on the secretion of key inflammation and hypoxia markers in amateur athletes.Methods: Twenty-three athletes with a mean age of 20.1 years, living at low altitude (1850 m) participated in this study. The participants' maximal oxygen consumption values (VO2max) were determined with an incremental cycle exercise test as 54.15 ± 6.14 mL kg min−1. Athletes performed four protocols: at rest, 50% VO2max, 75% VO2max and 100% VO2max (until exhaustion) with one-week intervals. 50% VO2max, 75% VO2max sessions were performed continuously for 30 min on a bicycle ergometer and 100% VO2max session was performed by cycling until exhaustion. Blood samples were obtained at rest and immediately after each exercise session. Serum tumor necrosis factor alpha (TNF-α), C-reactive protein (CRP), interleukin-10 (IL-10), and hypoxia inducible factor-1 alpha (HIF-1α) levels were measured.Results: There were significant differences in serum TNF-α levels in 75% VO2max and 100% VO2max sessions (489.03 ± 368.37 and 472.70 ± 365.21 ng/L, respectively) compared to rest conditions (331.65 ± 293.52 ng/L). Serum CRP levels of 50% VO2max and 75% VO2max sessions (1.19 ± 0.50; 1.07 ± 0.52 mg/L) were significantly higher than the rest condition (0.74 ± 0.35 mg/L). There were significant differences in serum IL-10 levels of rest condition and 50% VO2max; 50% VO2max, and 100% VO2max sessions (328.09 ± 128.87; 446.36 ± 142.84; 347.44 ± 135.69; 324.88 ± 168.06 pg/mL). Serum HIF-1α levels were significantly higher in 75% VO2 max session compared to rest (1.26 ± 0.16; 1.08 ± 0.19 ng/mL) (P < 0.05 for all comparisons).Conclusions: Both inflammatory and anti-inflammatory pathway is induced on different exercise intensities. Exercise protocols performed until exhaustion may lead to activation of inflammatory pathways and hypoxia-induced damage.

24 June 2025 in Nutrients
Verified
Journal Article
Open access
PDF file
SOSedat Okut
Sedat Okut
MOMurat Ozan
Murat Ozan
YBYusuf Buzdagli
Yusuf Buzdagli
HUHalil Uçar
Halil Uçar
İRİNAÇ MUHAMMET RAŞİT
İNAÇ MUHAMMET RAŞİT
NBNurcan Kılıç Baygutalp
Nurcan Kılıç Baygutalp
Objectives: This study aimed to comprehensively investigate the physiological effects of omega-3 fatty acid supplementation combined with resistance training on the lipid profile, inflammatory and antioxidant responses, neuro-biomarkers, and physical performance parameters in physically healthy young adults. Methods: Thirty physically active male participants were randomly assigned to an experimental group (omega-3 + resistance training) or a control group (resistance training only). Over eight weeks, both groups performed a standardized resistance training program three times per week. The experimental group additionally received 3150 mg/day of omega-3 fatty acids (EPA and DHA). Pre- and post-intervention assessments included blood biomarkers (LDL, HDL, triglycerides, IL-6, TNF-α, CRP, GSH, MDA, BDNF, serotonin, and dopamine) and physical performance tests (1RM, CMJ, RSI, 10 m sprint, and Illinois agility). Results: The experimental group showed significant improvements in the lipid profile, with decreases in LDL and triglyceride levels and an increase in HDL levels. Levels of the inflammatory cytokines IL-6 and TNF-α were significantly reduced, while GSH levels increased and MDA levels decreased, indicating an enhanced antioxidant status. The neuro-biomarker analysis revealed increased levels of BDNF, dopamine, and serotonin. Physical performance tests demonstrated greater improvements in muscular strength, power, speed, agility, and reaction-based performance in the omega-3 group compared to controls. Conclusions: These findings suggest that omega-3 supplementation, when combined with resistance training, has a multi-systemic enhancing effect on both physiological markers and physical performance. This combination may represent a promising strategy for optimizing athletic adaptations and recovery in physically active populations. Future studies should further explore these effects across different populations and training modalities.

13 January 2018 in Turkish Journal of Biochemistry
Verified
Journal Article
Closed access
PDF file
NBNurcan Kılıç Baygutalp
Nurcan Kılıç Baygutalp
EBEbubekir Bakan
Ebubekir Bakan
ZBZafer Bayraktutan
Zafer Bayraktutan
FUFatma Zuhal Umudum
Fatma Zuhal Umudum
Background: Glucose meters are used for two purposes: point-of-care testing and the self-monitoring of glucose, both of which are very important in the management of diabetes, hypoglycemia, or hyperglycemia and in therapeutic decisions. Objective: The aim of this study was to determine the test reliability of glucose meters and to compare their results with those of the clinical laboratory method. Material and methods: Evaluation was made of five different types of glucose meters which are generally used for hospitalized patients. Capillary and venous specimens were obtained concurrently from each patient. The former were analyzed in the glucose meters, and the latter in the laboratory analyzer. Results: Of 1837 glucose meters read-outs, 1748 capillary and venous comparisons were evaluated. The majority of the glucose meter measurements were within acceptable limits. The error percentage distribution of glucose meters indicated that the accuracy of glucose meters is higher in the prediabetic/diabetic measurement range than at normo-/hypoglycemic levels. Conclusion: In general, the glucose meters and laboratory method were observed to be compatible. However, health care professionals and self-monitoring diabetic patients should be aware of the evaluation of glucose meter results, and should cross-check, as frequently as possible, with laboratory values.