Alberto Tapetado Moraleda

Dr. Alberto Tapetado Moraleda

Carlos III University of Madrid
+1
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JAJ. F. Algorri
J. F. Algorri
Dimitrios ZografopoulosDimitrios Zografopoulos
Dimitrios Zografopoulos
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
DPDavid Poudereux
David Poudereux
JSJose Manuel Sanchez-Pena
Jose Manuel Sanchez-Pena
Photonic crystal fibers (PCFs) are a special class of optical fibers with a periodic arrangement of microstructured holes located in the fiber’s cladding. Light confinement is achieved by means of either index-guiding, or the photonic bandgap effect in a low-index core. Ever since PCFs were first demonstrated in 1995, their special characteristics, such as potentially high birefringence, very small or high nonlinearity, low propagation losses, and controllable dispersion parameters, have rendered them unique for many applications, such as sensors, high-power pulse transmission, and biomedical studies. When the holes of PCFs are filled with solids, liquids or gases, unprecedented opportunities for applications emerge. These include, but are not limited in, supercontinuum generation, propulsion of atoms through a hollow fiber core, fiber-loaded Bose–Einstein condensates, as well as enhanced sensing and measurement devices. For this reason, infiltrated PCF have been the focus of intensive research in recent years. In this review, the fundamentals and fabrication of PCF infiltrated with different materials are discussed. In addition, potential applications of infiltrated PCF sensors are reviewed, identifying the challenges and limitations to scale up and commercialize this novel technology.

26 September 2013 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
CVCarmen Vazquez
Carmen Vazquez
Joseba Zubia ZaballaJoseba Zubia Zaballa
Joseba Zubia Zaballa
JAJon Arrue
Jon Arrue
The design and development of a plastic optical fiber (POF) macrobend temperature sensor is presented. The sensor has a linear response versus temperature at a fixed bend radius, with a sensitivity of . The sensor system used a dummy fiber-optic sensor for reference purposes having a resolution below 0.3 °C. A comprehensive experimental analysis was carried out to provide insight into the effect of different surrounding media on practical macro-bend POF sensor implementation. Experimental results are successfully compared with bend loss calculations.

18 March 2015 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
PPP. J. Pinzon
P. J. Pinzon
JZJ. Zubia
J. Zubia
CVCarmen Vazquez
Carmen Vazquez
The design and development of a plastic optical fiber macrobend temperature sensor is presented. The sensor can operate in a temperature range from -55 to 70 °C and has a linear response versus temperature with a sensitivity of 8.95·10 -4 °C -1 . The sensor system uses the ratio of transmittance at two wavelengths to implement a self-referencing technique in order to avoid undesirable power fluctuations influence. The transmittance ratio precision is 0.1%. An analysis has been developed to find the two wavelengths which ratio offers the highest linearity and sensitivity response. Experimental results are successfully compared with theoretical approaches.

6 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
CVCarmen Vazquez
Carmen Vazquez
SPSandra Pérez-Prieto
Sandra Pérez-Prieto
JLJuan D. López-Cardona
Juan D. López-Cardona
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
EBEnrique Blanco
Enrique Blanco
PLPedro Contreras Lallana
Pedro Contreras Lallana
We report the experimental results on a new infrared fiber-optic pyrometer for very localized and high-speed temperature measurements ranging from 170 to 530 °C using low-noise photodetectors and high-gain transimpedance amplifiers with a single gain mode in the whole temperature range. We also report a shutter based on an optical fiber switch which is optically powered to provide a reference signal in an optical fiber pyrometer measuring from 200 to 550 °C. The tests show the potential of remotely powering via optical means a 300 mW power-hungry optical switch at a distance of 100 m, avoiding any electromagnetic interference close to the measuring point.

29 November 2016 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
José Díaz ÁlvarezJosé Díaz Álvarez
José Díaz Álvarez
HMH. Miguelez
H. Miguelez
CVCarmen Vazquez
Carmen Vazquez
A fiber-optic two-color pyrometer based on glass multimode fibers with 62.5 μm diameter and 0.275 numerical aperture is used for localized temperature measurements in turning processes. Operation wavelengths improve temperature measurement accuracy. The system is capable of measuring temperature in the range from 300 to 650 °C in a surface area below 0.16 mm 2 . Numerical simulation of the calibration curves including manufacturer tolerances are reported, showing good agreement with the experimental results. Temperature evolution is performed in a lathe at different feed rates and cutting speeds at an Inconel 718 turning process, using a glass fiber-optic sensor embedded into a modified tool member. The results are used to in-process prevent premature failure of the components related to the fatigue and validate feed rates recommended by the tool manufacturer.

10 May 2021 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
SAStefano Aretusini
Stefano Aretusini
ANArántzazu Núñez-Cascajero
Arántzazu Núñez-Cascajero
ESElena Spagnuolo
Elena Spagnuolo
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
CVCarmen Vazquez
Carmen Vazquez
GTGiulio Di Toro
Giulio Di Toro
The understanding of earthquake physics is hindered by the poor knowledge of fault strength and temperature evolution during seismic slip. Experiments reproducing seismic velocity (∼1 m/s) allow us to measure both the evolution of fault strength and the associated temperature increase due to frictional heating. However, temperature measurements were performed with techniques having insufficient spatial and temporal resolution. Here we conduct high velocity friction experiments on Carrara marble rock samples sheared at 20 MPa normal stress, velocity of 0.3 and 6 m/s, and 20 m of total displacement. We measured the temperature evolution of the fault surface at the acquisition rate of 1 kHz and over a spatial resolution of ∼40 µm with an optical fiber conveying the infrared radiation to a two‐color pyrometer. Temperatures up to 1,250°C and low coseismic fault shear strength are compatible with the activation of grain size dependent viscous creep.