The heating and cooling energy consumption of buildings accounts for about 15% of national total energy consumption in the United States. In response to this challenge, many promising technologies with minimum carbon footprint have been proposed. However, most of the approaches are static and monofunctional, which can only reduce building energy consumption in certain conditions and climate zones. Here, we demonstrate a dual-mode device with electrostatically-controlled thermal contact conductance, which can achieve up to 71.6 W/m2 of cooling power density and up to 643.4 W/m2 of heating power density (over 93% of solar energy utilized) because of the suppression of thermal contact resistance and the engineering of surface morphology and optical property. Building energy simulation shows our dual-mode device, if widely deployed in the United States, can save 19.2% heating and cooling energy, which is 1.7 times higher than cooling-only and 2.2 times higher than heating-only approaches.
Magnetic field gradients affect numerous modern sensitive measurements and physics studies using atomic ensemble, resulting in the loss of coherence. In some cases, the presence of small gradients can reduce the performance significantly. In this study, we propose an effective in situ method to compensate the triaxial magnetic field gradient for atomic magnetometers, based on multichannel atomic signals in one vapor cell. We design two novel gradient coils by solving closed-form equations to improve the accuracy and efficiency of compensation. We demonstrate the performance of the compensation method in a spin-exchange relaxation-free atomic magnetometer, which reduces the magnetic linewidth by 4.2%–7.6% under the same conditions at a compensation resolution of 50 pT/cm. The proposed coils generate gradients only along two axes and achieve triaxial decoupling, which compensates for the gradient completely without iteration. Our results may aid in suppressing atomic spin relaxations due to magnetic field gradients in several modern measurements and improve their performance, such as the detection of electric dipole moments, ultralow-field nuclear magnetic resonance, and biomagnetism.
This study proposes a high-performance magnetic shielding structure composed of MnZn ferrite and mu-metal film. The use of the mu-metal film with a high magnetic permeability restrains the decrease in the magnetic shielding coefficient caused by the magnetic leakage between the gap of magnetic annuli. The 0.1–0.5 mm thickness of mu-metal film prevents the increase of magnetic noise of composite structure. The finite element simulation results show that the magnetic shielding coefficient and magnetic noise are almost unchanged with the increase in the gap width. Compared with conventional ferrite magnetic shields with multiple annuli structures under the gap width of 0.5 mm, the radial shielding coefficient increases by 13.2%, and the magnetic noise decreases by 21%. The axial shielding coefficient increases by 22.3 times. Experiments verify the simulation results of the shielding coefficient of the combined magnetic shield. The shielding coefficient of the combined magnetic shield is 16.5%. It is 91.3% higher than the conventional ferrite magnetic shield. The main difference is observed between the actual and simulated relative permeability of mu-metal films. The combined magnetic shielding proposed in this study is of great significance to further promote the performance of atomic sensors sensitive to magnetic field.
Podocytes derived from human induced pluripotent stem (hiPS) cells are enabling studies of kidney development and disease. However, many of these studies are carried out in traditional tissue culture plates that do not accurately recapitulate the molecular and mechanical features necessary for modeling tissue- and organ-level functionalities. Overcoming these limitations requires the design and application of tunable biomaterial scaffolds. Silk fibroin is an attractive biomaterial due to its biocompatibility and versatility, which include its ability to form hydrogels, sponge-like scaffolds, and electrospun fibers and membranes appropriate for tissue engineering and biomedical applications. In this study, we show that hiPS cells can be differentiated into post-mitotic kidney glomerular podocytes on electrospun silk fibroin membranes functionalized with laminin. The resulting podocytes remain viable and express high levels of podocyte-specific markers consistent with the mature cellular phenotype. The resulting podocytes were propagated for at least two weeks, enabling secondary cell-based applications and analyses. This study demonstrates for the first time that electrospun silk fibroin membrane can serve as a supportive biocompatible platform for human podocyte differentiation and propagation. We anticipate that the results of this study will pave the way for the use of electrospun membranes and other biomimetic scaffolds for kidney tissue engineering, including the development of co-culture systems and organs-on-chips microphysiological devices.