Yanan Gao

Dr. Yanan Gao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2025 in Measurement
Verified
Journal Article
Closed access
YDYao Dou
Yao Dou
YGYanan Gao
Yanan Gao
KWKun Wang
Kun Wang
MZMengshi Zhang
Mengshi Zhang
JLJanli Li
Janli Li
DMDanyue Ma
Danyue Ma

5 September 2022 in Measurement
Verified
Journal Article
Closed access
SLSiran Li
Siran Li
DMDanyue Ma
Danyue Ma
JLJixi Lu
Jixi Lu
BXBozheng Xing
Bozheng Xing
KWKun Wang
Kun Wang
BHBangcheng Han
Bangcheng Han

19 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SLSiran Li
Siran Li
Jixi LuJixi Lu
Jixi Lu
DMDanyue Ma
Danyue Ma
KWKun Wang
Kun Wang
YGYanan Gao
Yanan Gao
BHBangcheng Han
Bangcheng Han
An in situ method has been proposed for measuring all nonorthogonal angles of the beams and triaxial coils in a three-axis vector optically pumped magnetometer (OPM). Based on the combination and alignment of two pump beams, each of which can achieve biaxial transverse measurement in a time-sharing regime under modulated magnetic fields, a 3-D orthogonal coordinate measurement system is obtained, and the measurement models for three categories (six types) of nonorthogonal angles are established theoretically. On this basis, we experimentally measured the nonorthogonal angles along with related uncertainties at different modulated frequencies and strengths of the magnetic fields. The nonorthogonal angles were (3.65° ± 0.52°) between the two pump beams before compensation. They were (7.05° ± 0.23°) between the $X$ - and $Y$ -axis coils, (8.89° ± 0.21°) between the $Y$ - and $Z$ -axis coils, (5.23° ± 0.27°) between the $X$ - and $Z$ -axis coils, (7.24° ± 0.24°) between the $x$ -direction pump beam and $X$ -axis coil, and (9.10° ± 0.22°) between the $z$ -direction pump beam and the $Z$ -axis coil. This study measures the magnitudes of six types of nonorthogonality, without making an assumption of ideal orthogonality or using auxiliary calibration equipment. Moreover, this method can be extended to several other kinds of OPMs with simple modifications. This study is critical for evaluating and reducing the misalignment error to improve the accuracy of three-axis vector OPMs.

31 January 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KWKun Wang
Kun Wang
JSJinji Sun
Jinji Sun
DMDanyue Ma
Danyue Ma
SLSiran Li
Siran Li
YGYanan Gao
Yanan Gao
JZJiahe Zhang
Jiahe Zhang
Triaxial uniform coils installed in the magnetically shielded cylinder are essential components of an atomic magnetometer to achieve ultra-sensitive measurements and are used to compensate for the ambient magnetic remanence in the magnetometer’s operating area. This paper proposes the new three-dimensional octagonal coils configured with a two-pair octagonal coil and two double-nested octagonal coils, which differs from the conventional square or circular shim coils. The spatially homogeneous distribution of the magnetic field of the three-dimensional shim coils based on this configuration is simulated and evaluated, and then the fabrication and experimental tests are completed. The theoretical calculation results show that the magnetic field uniformity of the z-direction two-pair octagonal coil is improved by about one order of magnitude compared with that of the conventional coil such as the Lee-Whiting coil and the Rubens coil. The magnetic field uniformity of x-direction or y-direction double nested octagonal coil is promoted by about two orders of magnitude compared with that of saddle coil. The experimental magnetic field distribution is consistent with the theoretical value. This configuration can reduce the outer diameter of the coil under the premise of meeting the requirement of setting the magnetic field uniform zone, and it is easier to install than the cylindrical coil assemblies.

18 April 2024 in Measurement
Verified
Journal Article
Closed access
YGYanan Gao
Yanan Gao
XFXiujie Fang
Xiujie Fang
DMDanyue Ma
Danyue Ma
BSBowen Sun
Bowen Sun
KWKun Wang
Kun Wang
MZMin Zeng
Min Zeng

7 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KWKun Wang
Kun Wang
DMDanyue Ma
Danyue Ma
SLSiran Li
Siran Li
YMYanning Ma
Yanning Ma
YGYanan Gao
Yanan Gao
JSJinji Sun
Jinji Sun
The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in-situ calibration, we firstly studied the transient atomic dynamics of a dual beam SERF atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction decay (FID) curves by alternately applying square wave signals to the x -, y - and z -axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x-y , y-z , and z-x , respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.