Vittorio Di Trapani

Dr. Vittorio Di Trapani

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
RLRenata Longo
Renata Longo
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
UBUbaldo Bottigli
Ubaldo Bottigli
LBLUCA BROMBAL
LUCA BROMBAL
GTGiuliana Tromba
Giuliana Tromba

1 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
DDDiego Dreossi
Diego Dreossi
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
RLRenata Longo
Renata Longo
X-ray phase imaging has the potential to dramatically improve soft tissue contrast sensitivity, which is a crucial requirement in many diagnostic applications such as breast imaging. In this context, a program devoted to perform in vivo phase-contrast synchrotron radiation breast computed tomography is ongoing at the Elettra facility (Trieste, Italy). The used phase-contrast technique is the propagation-based configuration, which requires a spatially coherent source and a sufficient object-to-detector distance. In this work the effect of this distance on image quality is quantitatively investigated scanning a large breast surgical specimen at three object-to-detector distances (1.6, 3, 9 m) and comparing the images both before and after applying the phase-retrieval procedure. The sample is imaged at 30 keV with a pixel pitch CdTe single-photon-counting detector, positioned at a fixed distance of 31.6 m from the source. The detector fluence is kept constant for all acquisitions. The study shows that, at the largest distance, a 20-fold SNR increase can be obtained by applying the phase-retrieval procedure. Moreover, it is shown that, for phase-retrieved images, changing the object-to-detector distance does not affect spatial resolution while boosting SNR (four-fold increase going from the shortest to the largest distance). The experimental results are supported by a theoretical model proposed by other authors, whose salient results are presented in this paper.

1 June 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
Francesco BrunFrancesco Brun
Francesco Brun
PDPasquale Delogu
Pasquale Delogu
VFViviana Fanti
Viviana Fanti
BGBruno Golosio
Bruno Golosio

1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
APAnna Piai
Anna Piai
ACAdriano Contillo
Adriano Contillo
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
LBLUCA BROMBAL
LUCA BROMBAL
RLRenata Longo
Renata Longo
A quantitative characterization of the soft tissues composing the human breast is achieved by means of a monochromatic CT phase-contrast imaging system, through accurate measurements of their attenuation coefficients within the energy range of interest for breast CT clinical examinations. Quantitative measurements of linear attenuation coefficients are performed on tomographic reconstructions of surgical samples, using monochromatic x-ray beams from a synchrotron source and a free space propagation setup. An online calibration is performed on the obtained reconstructions, in order to reassess the validity of the standard calibration procedure of the CT scanner. Three types of healthy tissues (adipose, glandular, and skin) and malignant tumors, when present, are considered from each sample. The measured attenuation coefficients are in very good agreement with the outcomes of similar studies available in the literature, although they span an energy range that was mostly neglected in the previous studies. No globally significant differences are observed between healthy and malignant dense tissues, although the number of considered samples does not appear sufficient to address the issue of a quantitative differentiation of tumors. The study assesses the viability of the proposed methodology for the measurement of linear attenuation coefficients, and provides a denser sampling of attenuation data in the energy range useful to breast CT.

1 March 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
VTVittorio Di Trapani
Vittorio Di Trapani
ABA. Bravin
A. Bravin
Francesco BrunFrancesco Brun
Francesco Brun
DDD. Dreossi
D. Dreossi
RLR. Longo
R. Longo
PDP. Delogu
P. Delogu

23 December 2022 in Optics Express
Verified
Journal Article
Closed access
FMFabio De Marco
Fabio De Marco
SSSara Savatović
Sara Savatović
RSRonan Smith
Ronan Smith
VTVittorio Di Trapani
Vittorio Di Trapani
MMMarco Margini
Marco Margini
PTPierre Thibault
Pierre Thibault
Wavefront-marking X-ray imaging techniques use e.g., sandpaper or a grating to generate intensity fluctuations, and analyze their distortion by the sample in order to retrieve attenuation, phase-contrast, and dark-field information. Phase contrast yields an improved visibility of soft-tissue specimens, while dark-field reveals small-angle scatter from sub-resolution structures. Both have found many biomedical and engineering applications. The previously developed Unified Modulated Pattern Analysis (UMPA) model extracts these modalities from wavefront-marking data. We here present a new UMPA implementation, capable of rapidly processing large datasets and featuring capabilities to greatly extend the field of view. We also discuss possible artifacts and additional new features.