Mateja Budetić

Dr. Mateja Budetić

Department of Chemistry, J.J. Strossmayer University of Osijek, Osijek, Osječko-Baranjska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2023 in Molecules
Verified
Journal Article
Open access
PDF file
Mateja BudetićMateja Budetić
Mateja Budetić
DKDoris Kopf
Doris Kopf
Andrea DandicAndrea Dandic
Andrea Dandic
Mirela SamardžićMirela Samardžić
Mirela Samardžić
Thiabendazole (TBZ) is a fungicide and anthelmintic drug commonly found in food products. Due to its toxicity and potential carcinogenicity, its determination in various samples is important for public health. Different analytical methods can be used to determine the presence and concentration of TBZ in samples. Liquid chromatography (LC) and its subtypes, high-performance liquid chromatography (HPLC) and ultra-high-performance liquid chromatography (UHPLC), are the most commonly used methods for TBZ determination representing 19%, 18%, and 18% of the described methods, respectively. Surface-enhanced Raman spectroscopy (SERS) and fluorimetry are two more methods widely used for TBZ determination, representing 13% and 12% of the described methods, respectively. In this review, a number of methods for TBZ determination are described, but due to their limitations, there is a high potential for the further improvement and development of each method in order to obtain a simple, precise, and accurate method that can be used for routine analysis.

1 January 2022 in Reviews in Analytical Chemistry
Verified
Journal Article
Open access
PDF file
Andrea DandicAndrea Dandic
Andrea Dandic
KRKatarina Rajkovača
Katarina Rajkovača
MJMarija Jozanović
Marija Jozanović
IPIva Pukleš
Iva Pukleš
ASAleksandar Széchenyi
Aleksandar Széchenyi
Mirela SamardžićMirela Samardžić
Mirela Samardžić
Nonsteroidal anti-inflammatory drugs (NSAIDs) are the first choice of treatment for rheumatic disorders and other degenerative inflammatory diseases. One of them, indomethacin (INDO), is highlighted in this study. With its analgesic, antipyretic, and anti-inflammatory properties, it is one of the most powerful drugs used in various clinical trials and therapies related to the mechanism of blocking prostaglandin synthesis, thus reducing and eliminating many inflammatory conditions in patients. To ensure the efficacy and safety of this drug in pharmaceutical and clinical use, precise product quality control is required. Such control is performed with routine pharmaceutical analysis using various chemical methods by which INDO is identified as a separate active ingredient in the multicomponent system of a complete pharmaceutical form. In addition, the determination of INDO is important in clinical practice, where its concentration is determined in different biological samples, ensuring better monitoring of a particular therapy. The most commonly used methods for the determination of INDO are high-performance liquid chromatography (37% of developed methods), voltammetry (16% of developed methods), and UV spectroscopy (11% of developed methods). However, each of these methods must provide precise validation parameters. A combination of analytical methods can lead to more precise results and safer application in practice.

16 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea DandicAndrea Dandic
Andrea Dandic
INIvana Novak
Ivana Novak
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
IPIva Pukleš
Iva Pukleš
ASAleksandar Széchenyi
Aleksandar Széchenyi
Mirela SamardžićMirela Samardžić
Mirela Samardžić
Direct potentiometric measurements using solid-state sensors have a great potential for thiabendazole (TBZ) determination, considering simplicity, accuracy, and low cost. Modifying the sensing material of the sensor with multi-walled carbon nanotubes (MWCNTs) leads to improved analytical properties of the sensor. In this study, a new potentiometric solid-state sensor for TBZ determination, based on MWCNTs modified with a sulfate group, and TBZ ion as sensing material was developed. The sensor exhibited a Nernstian response for TBZ (60.4 mV/decade of activity) in a working range between 8.6 × 10−7 and 1.0 × 10−3 M. The detection limit for TBZ was 6.2 × 10−7 M. The response time of the sensor for TBZ was 8 s, and its signal drift was only 1.7 mV/h. The new sensor is applicable for direct potentiometric determination of TBZ in complex real samples, such as fruit peel. The accuracy of TBZ determination is confirmed using the standard addition method.

27 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Mirela SamardžićMirela Samardžić
Mirela Samardžić
MPMateja Peršić
Mateja Peršić
ASAleksandar Széchenyi
Aleksandar Széchenyi
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
IPIva Pukleš
Iva Pukleš
Mateja BudetićMateja Budetić
Mateja Budetić
Promethazine hydrochloride (PM) is a widely used drug so its determination is important. Solid-contact potentiometric sensors could be an appropriate solution for that purpose due to their analytical properties. The aim of this research was to develop solid-contact sensor for potentiometric determination of PM. It had a liquid membrane containing hybrid sensing material based on functionalized carbon nanomaterials and PM ions. The membrane composition for the new PM sensor was optimized by varying different membrane plasticizers and the content of the sensing material. The plasticizer was selected based on calculations of Hansen solubility parameters (HSP) and experimental data. The best analytical performances were obtained using a sensor with 2-nitrophenyl phenyl ether (NPPE) as the plasticizer and 4% of the sensing material. It had a Nernstian slope (59.4 mV/decade of activity), a wide working range (6.2 × 10−7 M–5.0 × 10−3 M), a low limit of detection (1.5 × 10−7 M), fast response time (6 s), low signal drift (−1.2 mV/h), and good selectivity. The working pH range of the sensor was between 2 and 7. The new PM sensor was successfully used for accurate PM determination in a pure aqueous PM solution and pharmaceutical products. For that purpose, the Gran method and potentiometric titration were used.

Verified
Journal Article
Open access
PDF file
IPIva Pukleš
Iva Pukleš
CPCsilla Páger
Csilla Páger
Nikola SakačNikola Sakač
Nikola Sakač
BSBojan Sarkanj
Bojan Sarkanj
Brunislav MatasovićBrunislav Matasović
Brunislav Matasović
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
The health supplement industry is one of the fastest growing industries in the world, but there is a lack of suitable analytical methods for the determination of active compounds in health supplements such as peptides. The present work describes an implementation of contactless conductivity detection on microchip technology as a new strategy for the electrophoretic determination of L-carnosine in complex health supplement formulations without pre-concentration and derivatization steps. The best results were obtained in the case of +1.00 kV applied for 20 s for injection and +2.75 kV applied for 260 s for the separation step. Under the selected conditions, a linear detector response of 5 × 10−6 to 5 × 10−5 M was achieved. L-carnosine retention time was 61 s. The excellent reproducibility of both migration time and detector response confirmed the high precision of the method. The applicability of the method was demonstrated by the determination of L-carnosine in three different samples of health supplements. The recoveries ranged from 91 to 105%. Subsequent analysis of the samples by CE-UV-VIS and HPLC-DAD confirmed the accuracy of the obtained results.

6 July 2021 in Journal of Surfactants and Detergents
Verified
Journal Article
Closed access
PDF file
MAMaja Aničić
Maja Aničić
Mateja BudetićMateja Budetić
Mateja Budetić
TDTihana Dekanić
Tihana Dekanić
KGKatia Grgić
Katia Grgić
TPTanja Pušić
Tanja Pušić
Mirela SamardžićMirela Samardžić
Mirela Samardžić