Keitaro Ito

Mr. Keitaro Ito

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
KIKeitaro Ito
Keitaro Ito
SSShinya Sakuma
Shinya Sakuma
MKMasaki Kimura
Masaki Kimura
TTTakanori Takebe
Takanori Takebe
MKMakoto Kaneko
Makoto Kaneko
AFArai Fumihito
Arai Fumihito
In this paper, we focus on the mechanical characterization of co-cultured spheroids of human umbilical vein endothelial cells (HUVECs) and mesenchymal stem cells (MSC) (HUVEC/MSC spheroids). HUVEC/MSC spheroids aggregate during culture, thereby decreasing in size. Since this size decrease can be caused by the contractility generated by the actomyosin of MSCs, which are intracellular frames, we can expect that there is a temporal transition for the mechanical characteristics, such as stiffness, during culture. To measure the mechanical characteristics, we use a microfluidic chip that is integrated with force sensor probes. We show the details of the measurement configuration and the results of mechanical characterization of the HUVEC/MSC spheroids. To evaluate the stiffness of the spheroids, we introduce the stiffness index, which essentially shows a spring constant per unit size of the spheroid at a certain time during measurement. From the measurement results, we confirmed that the stiffness index firstly increased during the days of culture, although after four days of culture, the stiffness index decreased. We confirmed that the proposed system can measure the stiffness of HUVEC/MSC spheroids.

30 August 2014 in ROBOMECH Journal
Verified
Journal Article
Open access
PDF file
KIKeitaro Ito
Keitaro Ito
SSShinya Sakuma
Shinya Sakuma
YYYoshiyuki Yokoyama
Yoshiyuki Yokoyama
FAFumihito Arai
Fumihito Arai
Microfluidic chips are powerful tools for biochemical experiments. High speed and precise flow control can be achieved by using microvalves on a chip. Several types of microvalves that can be integrated into a microfluidic chip have been reported. Among them, gel microvalves have certain advantages over other valves because of their soft structure, which will contribute to prevent mechanical damage the cells passing though the valve. Here we use Bioresist, a photoprocessable thermoresponsive gel, as a key component of the microvalve. Since Bioresist is photopatternable, we can create any arbitrary 2D shape from the thermoresponsive gel using photolithography. Moreover, Bioresist has the unique feature of a phase transition around 30°C, and swells and shrinks repeatedly with temperature change. By integrating the patterned thermoresponsive gel with a microheater, we developed a gel actuator and designed a gel-valve. The gel-valve has the advantages of a simple actuation mechanism: high leakage pressure, high speed actuation and low power consumption. The valve is biocompatible and easily integrated into a chip by using conventional photolithography. Using this valve, we achieved on-chip flow control, and applied it to cell sorting on a chip.

14 January 2026 in IEEE Sensors Letters
Verified
Journal Article
Closed access
KIKeitaro Ito
Keitaro Ito
TATeruhisa Akashi
Teruhisa Akashi
HFHirofumi Funabashi
Hirofumi Funabashi
SHShota Harada
Shota Harada
HWHiroyuki Wado
Hiroyuki Wado
Assembly-induced stresses such as printed circuit board (PCB) warpage and clamp loads propagate through the package to the MEMS die and perturb accelerometer bias. This letter presents a PCB-integrated stress-relief structure: a planar, fourfold-symmetric crab-leg (folded-beam) flexure that forms an “IMU island” via through-slots, attenuating stress transmission regardless of load direction while preserving four-sided routing. Finite-element analysis of a molded inertial measurement unit (IMU) package on a clamped–clamped PCB under mid-span deflection shows that the area-averaged von Mises stress at the MEMS anchor interface is reduced to 0.23× compared with a plain PCB. A clamped–clamped bending fixture with a recessed loading pin, load sensing, 3-D surface profiling, and a calibration–inference procedure maps measured displacements to a plain-PCB-equivalent surface stress, enabling fair comparison across layouts over an approximately ±40 MPa range. Measurements confirm that, relative to the plain PCB, accelerometer bias change decreases from 4.9 mG to 1.6 mG on X (0.32×) and from 48 mG to 8.4 mG on Z (0.18×), with no clear reduction on Y. These results demonstrate that board-level flexures reduce assembly-induced bias drift and provide a practical, user-implementable approach to stabilize MEMS IMU accelerometers without altering the device or package.

1 January 2012 in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Verified
Journal Article
Closed access
PDF file
KIKeitaro Ito
Keitaro Ito
SSShinya Sakuma
Shinya Sakuma
FAFumihito Arai
Fumihito Arai
NUNobuyuki Uozumi
Nobuyuki Uozumi
KNKei Nanatani
Kei Nanatani
In this paper, we propose the on-chip capacitive force sensor for ultrahigh speed cellular force measurement. In order to apply the capacitive force sensor to microfluidic chip, on-chip force sensor utilizes the air-liquid interface due to isolate liquid form comb electrodes. We have designed and fabricated the capacitive force sensor with cell culture chamber as a kind of microchannel to the several pm order cell. Air-liquid interface between the force sensor tip and comb electrodes have achieved. As a result, we have succeeded in measurement of capacitance of on-chip force sensor as a function of displacement of probe tip in wet condition.

1 January 2015 in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Verified
Journal Article
Open access
PDF file
SSShinya Sakuma
Shinya Sakuma
KIKeitaro Ito
Keitaro Ito
MKMakoto Kaneko
Makoto Kaneko
AFArai Fumihito
Arai Fumihito

1 January 2013 in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Verified
Journal Article
Closed access
PDF file
KIKeitaro Ito
Keitaro Ito
SSShinya Sakuma
Shinya Sakuma
YYYoshiyuki Yokoyama
Yoshiyuki Yokoyama
FAFumihito Arai
Fumihito Arai
We present an innovative polymer actuator made of photoprocessible thermo-sensitive gel. The gel, which we call "Bioresist", is thermo responsible biocompatible photoresist. Novelties of this Bioresist are shown as follows. (1) It is possible to fabricate arbitrary 2D pattern using photolithography. (2) Its volume is controlled by only heating. Therefore, it can be applied to the thermally controllable functional microfluidic devices. Herein, we demonstrated this innovative gel as applications of microfluidic components controlled by microheaters. Its properties were evaluated. Firstly, the relationship between expansion rate of Bioresist and temperature was measured. Secondly, the normally closed microvalve was fabricated for the fluid control. Then, the performance of this gel actuator was evaluated. Finally, we applied this microcomponent to the sorter of cells flowing in the microchannel.