Ryan Elie Harouny

Dr. Ryan Elie Harouny

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Rim BourgiRim Bourgi
Rim Bourgi
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
WDWalter Devoto
Walter Devoto
CKCynthia Kassis
Cynthia Kassis
Youssef HaikelYoussef Haikel
Youssef Haikel
One of the major goals of adhesive dentistry is to improve the interaction of the already-existing adhesives with different substrates by using different application techniques. Thus, the objective of the present in vitro study was to assess the bond performance of four adhesive systems, Prime&Bond Universal (PBU), Clearfil SE Bond (CSE), OptiBond Universal (OBU), and OptiBond FL (OBFL), to dentin using various application modes: passive application (PA), active application (AA), Compo-Vibes modified application (CVM), and Compo-Vibes application (CV). Eighty extracted human molars were allocated into four groups based on the application modalities tested. The micro-tensile bond strength as well as fracture mode were tested in accordance with ISO/TS 11.405 after 24 h and 6 months of aging. Adhesive contact angle (CA) and scanning electron microscope analysis were also performed (n = 3). Statistical tests were performed with α = 0.05. After 24 h, a significant difference with a higher bond strength value was found for PBU in the AA modality and for CSE in the CVM modality (p < 0.05). However, no significant difference was shown between the techniques used among the other adhesives (OBFL and OBU). Moreover, at 24 h, only the PA demonstrated significant differences between the tested materials (p < 0.05). After 6 months, CSE, PBU, and OBU demonstrated significant differences between the techniques (p < 0.05), with a higher bond strength for CSE in AA and CVM modalities, for PBU in AA modality, and for OBU in AA and PA modalities. No significant differences were found between the techniques used among the OBFL (p > 0.05). In addition, only the CVM technique demonstrated significant differences between the tested materials after 6 months. CV and CVM showed a decreased value after aging for CSE and PBU, respectively. However, all the modalities decreased for OBU and OBFL after aging. All the adhesives showed marked resin infiltration into dentinal tubules in AA among all the modalities tested. Both universal adhesive systems (OBU and PBU) demonstrated statistically lower CA when compared to the other systems (CSE and OBFL) (p < 0.05) when applied in the PA mode. Concerning the AA mode, only CSE and OBFL were tested. The AA demonstrated lower CA values compared to the same adhesives in PA (p < 0.05). It could be concluded that the bond strength could be influenced by both materials and application techniques. It seems that the AA technique could be recommended as a gold standard for the application of an adhesive system to dentin. Plus, the CV and CVM modalities after 6 months of aging were considered stable for PBU and CSE, respectively. Consequently, the performance of these adhesive systems might vary when applied to other modalities. Future studies are needed to test this hypothesis.

29 June 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
RHRyan Elie Harouny
Ryan Elie Harouny
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
EHElie Harouny
Elie Harouny
CKCynthia Kassis
Cynthia Kassis
Rim BourgiRim Bourgi
Rim Bourgi
CKCarlos Khairallah
Carlos Khairallah
The salivary contamination occurring at the try-in procedures of lithium disilicate (LDS) can jeopardize their bond strength. Various laboratory reports have concluded that applying 37% phosphoric acid (H3PO4) could be considered as a predictable way of removing salivary contaminants. An experimental method that consists of sealing the intaglio of the ceramic restorations with a layer of cured adhesive could allow consequent time saving for dental practitioners. It is, besides, necessary to establish an optimal decontamination protocol. Hence, this study aimed to determine the most efficient surface treatment, before and after salivary contamination, by comparing the adhesion between resin and LDS. In order to do so, five groups of ten specimens (n = 10) each underwent the different types of surface treatments before bonding, followed by 2500 cycles in the thermocycler. A shear bond strength (SBS) test was then conducted on a universal testing machine (YLE GmbH Waldstraße Bad König, Germany), followed by a fracture-type analysis on an optical microscope (Olympus BX53, Shinjuku, Tokyo, Japan). Statistical analysis was set with a level of significance of α = 0.05. The surface treatment significantly affected the SBS results. The decontamination with HF (12.59 ± 2.71 MPa) and H3PO4 (13.11 ± 1.03 MPa) obtained the highest values, silanizing only before contamination obtained intermediate values (11.74 ± 3.49 MPa), and silanizing both before and after the salivary contamination (10.41 ± 2.75 MPa) along with applying a bonding agent before contamination (9.65 ± 1.99 MPa) resulted in the lowest values. In conclusion, H3PO4 proved to be efficient, thus, allowing the practitioner to avoid the clinical use of HF; it can, therefore, be considered as a valid alternative. Presilanization and resilanization of specimens, along with applying a bonding agent before contamination, did not yield satisfying results.

8 June 2023 in Coatings
Verified
Journal Article
Open access
PDF file
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Rim BourgiRim Bourgi
Rim Bourgi
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
MGMaroun Ghaleb
Maroun Ghaleb
KKKhalil Kharma
Khalil Kharma
Monika Lukomska-SzymanskaMonika Lukomska-Szymanska
Monika Lukomska-Szymanska
Recently, the use of antioxidants before the bonding of bleached enamel was considered effective for reversing the reduction in the bond strength. This article aimed to assess the influence of different sodium ascorbate (SA) presentations (liquid, gel, and semi-gel) on the composite resin–enamel bond strength after a bleaching protocol. Sound human anterior teeth were collected, cleaned, prepared for a bond strength test, and randomly allocated into groups according to the bonding procedure. Group 1 acted as a control, without bleaching treatment, and without applying an antioxidant agent. In groups 2–6, specimens were bleached using 10% carbamide peroxide. In groups 3, 4 and 5, 10% wt% SA was applied for 10 min as an antioxidant in the form of a liquid, gel, and semi-gel, respectively. In group 6, samples were bleached and immersed in fresh human saliva for 14 days. After the bleaching process, the materials were restored by means of an adhesive system and a resin composite material. The analysis revealed that the differences between the shear bond strength (SBS) between the different groups were statistically significant (p = 0.0469). The highest SBS was achieved for the group where the 10 wt% SA liquid was applied before the bonding procedures. The application of liquid 10 wt% SA might reverse the negative impact that bleaching has on the bond strength of a resin composite and enamel.

15 November 2023 in International Arab Journal of Dentistry
Verified
Journal Article
Open access
PDF file
CHCamille Haddad
Camille Haddad
RHRyan Elie Harouny
Ryan Elie Harouny
LNLara Nasr
Lara Nasr
KCKarim Corbani
Karim Corbani
RTRonn Tassidis
Ronn Tassidis
Introduction: The purpose of this in vitro study was to test the influence of the margin design of implant supported monolithic zirconia crowns and test if monolithic zirconia crowns with extra fine finish line thickness cemented on zirconia implant abutments can bare the maximum masticatory forces on molars and hence be used in the posterior region. Methods: Fourteen identical monolithic zirconia crowns cemented on zirconia implant abutments mounted on titanium bases and fixed on implant replicas embedded in PMMA resin were divided into two groups: group I designed with a 0.5 mm CFL (CFL) and group II with a feather-edge finish line (FEFL) of 0.3 mm. All specimens underwent static load until fracture in order to determine the break force. Break forces in N were recorded for each group. Results: The CFL group exhibited slightly higher fracture resistance (1879.14 ± 322.28 N) compared to the feather-edge finish line group (1685.00 ± 362.18 N). However, statistical analysis revealed that the observed difference between the two groups (194.14 ± 183.24; p = 0.310) was not significant. Conclusions: Within the limitations of this study, both monolithic zirconia crowns with 0.5 mm chamfer and 0.3 mm feather edge margins cemented on zirconia implant abutments can be used in the posterior region as their resistance to fracture is similar and surpasses the maximum masticatory force applied on molars.

24 May 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
KKKhalil Kharma
Khalil Kharma
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
CKCynthia Kassis
Cynthia Kassis
Bogdan DimitriuBogdan Dimitriu
Bogdan Dimitriu
RHRyan Elie Harouny
Ryan Elie Harouny
Carina MehannaCarina Mehanna
Carina Mehanna
Modern conservative dentistry is taking the lead in daily clinical practice and is relying on adhesion. Whether it is a simple composite, ceramic inlays, onlays, veneers or crowns, the common factor for a successful outcome is a good bonding of these elements to dental structures. Thus, the purpose of this study was to evaluate the bond strength of resin composite to dentin when using a new device, the DENTIPURE KM™ (KM, Beirut, Lebanon), which provides a pure air flow, free of any contaminants and without humidity, when compared to other dental equipment. One hundred and eighty extracted human molars were equally divided into three groups according to the device used, the DENTIPURE KM™ (KM, Beirut, Lebanon), the KAVO™ (ESTETICA E30/E70/E80 Vision, KAVO, Biberach, Germany), or the ADEC™ (A-dec Performer 200, Newberg, OR, USA). The shear bond strength (SBS) was evaluated after 24 h of storage in distilled water on a universal testing machine. Statistical analysis was set with a level of significance at p ≤ 0.05. The results revealed that significantly different bond strength was imparted by the DENTIPURE KM™ device and the ADEC™ dental unit (p = 0.042). In conclusion, while the DENTIPURE KM™ device shows promise in providing contaminant-free air during bonding, its impact on dentin bond strength compared to devices like the KAVO™ appears minimal. Further research is needed to fully assess its potential in enhancing dentinal adhesion procedures.

1 November 2024 in International Arab Journal of Dentistry
Verified
Journal Article
Open access
PDF file
MKMaya Kabbara
Maya Kabbara
RHRyan Elie Harouny
Ryan Elie Harouny
HRHabib Rahme
Habib Rahme
Objectives: The primary objective of this study is to investigate the resistance to fracture of Polyetherketoneketones PEKK, used as post and core by fabrication in different diameters in the canal, and comparing the test results for each group. Methods: Thirty extracted mandibular premolars were selected, endodontically treated and prepared to receive the post and cores milled from polyetherketoneketone disk. The specimens were randomly divided into five groups (n = 6) respectively: group 1 received pekk post with diameter = 0.70 mm, group 2 received pekk post with diameter = 0.90 mm, group 3 received pekk post with diameter = 1.10 mm, group 4 received pekk post with diameter = 1.50 mm, and group 5 received pekk post with diameter = 1.70 mm. All the posts were cemented using a self-adhesive resin cement. Fracture resistance was tested using a universal testing machine, failure patterns were then observed visually and radiographically. For the fracture resistance test, the Universal Testing machine employed the load cell of 10KN and the speed of the cross head of 1mm/min. Data was analyzed using Oneway analysis of variance (ANOVA) followed by Tukey post-hoc test in order to determine significant differences among groups and the materiality threshold was set at α = 0.05. Results: Statistical analysis revealed that the observed differences among the five groups were not significant. None of the PEKK posts caused any fracture in the root, and this observation was visually and radiographically confirmed across all groups. Conclusions: The dentist will be able to turn the diameter of the PEKK post and core as thin as 0.70mm till 1.70mm depending on the clinical requirement with no risk of root fracture, as specified by the guidelines of this research.