The daily non-uniform power demand is a serious problem in power industry. In addition, recent decades show a trend for the transition to renewable power sources, but their power output depends upon weather and daily conditions. These factors determine the urgency of energy accumulation technology research and development. The presence of a wide variety of energy storage mechanisms leads to the need for their classification and comparison as well as a consideration of possible options for their application in modern power units. This paper presents a comparative analysis of energy storage methods for energy systems and complexes. Recommendations are made on the choice of storage technologies for the modern energy industry. The change in the cost of supplied energy at power plants by integrating various energy storage systems is estimated and the technologies for their implementation are considered. It is revealed that in the large-scale power production industry, the most productive accumulation methods for energy systems and complexes are the following: pumped hydroelectric energy storage systems, thermal and thermochemical accumulations, and hydrogen systems. These methods have the best technical and economic characteristics. The resulting recommendations allow for the assessment of the economic and energy effect achieved by integration of storage systems at the stage of designing new power units.
The most effective and environmentally safe fossil fuel power production facilities are the combined cycle gas turbine (CCGT) ones. Electric efficiency of advanced facilities is up to 58% in Russia and up to 64% abroad. The further improvement of thermal efficiency by increase of the gas turbine inlet temperature (TIT) is limited by performance of heat resistance alloys that are used for the hot gas path components and the cooling system efficiency. An alternative method for the CCGT efficiency improvement is utilization of low potential heat of the heat recovery steam generator (HRSG) exhaust gas in an additional cycle operating on a low-boiling heat carrier. This paper describes a thermodynamic analysis of the transition from binary cycles to trinary ones by integration of the organic Rankine cycle (ORC). A mathematical model of a cooled gas turbine plant (GT) has been developed to carry out calculations of high-temperature energy complexes. Based on the results of mathematical modeling, recommendations were made for the choice of the structure and parameters of the steam turbine cycle, as well as the ORC, to ensure the achievement of the maximum thermal efficiency of trinary plants. It is shown that the transition from a single pressure CCGT to a trinary plant allows the electric power increase from 213.4 MW to 222.7 MW and the net efficiency increase of 2.14%. The trinary power facility has 0.45% higher efficiency than the dual pressure CCGT.
The fuel price increase and severe environmental regulations determine energy-saving importance. Useful utilization of low-potential heat sources with 300–400 °С temperature becomes topical. The application of low-temperature power production facilities operating low-boiling heat carriers could be a solution to this problem. A comparative parametric study of a number of heat carriers resulted in a choice of the most promising fluids that are not expensive, have low toxicity and flammability, low ozone depletion and low global warming potential. These heat carriers are considered for application in simple power production cycles with and without regeneration. The main parameters were optimized at the initial temperatures of 323.15–623.15 K. The cycle without regeneration has a maximal net efficiency of 29.34% using the water at an initial temperature of 623.15 K. The regenerative cycle at a temperature below 490 K has its maximal efficiency using a water heat carrier, and at a higher temperature above 490 K with R236ea. The cycle with R236ea at 623.15 K has an electrical net efficiency of 33.30%. Using a water heat carrier, the maximal efficiency can be reached at pressures below 5 MPa for both cycles. Among the organic heat carriers, the minimal optimal initial pressure of a simple cycle is reached with the R236ea heat carrier below 45 MPa without regeneration and below 15 MPa with regeneration. Therefore when utilizing the latent heat with temperatures above 500 K R134a, R236ea and R124 are the most promising organic fluids. Such conditions could be obtained using different industrial sources with water condensation at elevated pressures.
The co-generation facilities have maximal thermal efficiency. In the case of the Russian Federation, for the power production industry, the development of the co-generation combined cycle facilities (CCGT-CHP) is especially urgent. The CCGT-CHP daily load schedule requires the demand of both electricity and heat, and the heat demand depends only upon the ambient air temperature. The gas turbine power reduction and the subsequent steam turbine power reduction during the electric load drop down are limited by the necessity to maintain the steam flow to district water heater to supply heat power. Methane steam reforming allows the recovery of the excess steam heat in the form of synthetic gas together with the CCGT-CHP electric power reduction. This paper considers three versions of the CCGT-CHP steam use in the Methane reforming: Bleeding steam supply, throttling of the heat recovery steam generator exit steam and the supply of this steam to the steam production in a steam transformer. Steam Methane reforming allows a reduction in the steam turbine supply power of 25% during the electric system power drop down. In the daytime, during the maximal system load, the produced synthetic gas is used and it is necessary to use the peak load gas turbine, which allows a 23% electric power increase. Energy storage by steam Methane reforming increases the contribution margin by 2.9%.