Amr A Mahrous

Prof. Dr. Amr A Mahrous

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2022 in Polymers
Verified
Journal Article
Open access
PDF file
PEPassent Ellakany
Passent Ellakany
SFShaimaa Mohamed Fouda
Shaimaa Mohamed Fouda
AMAmr A Mahrous
Amr A Mahrous
MAMaram A. AlGhamdi
Maram A. AlGhamdi
NANourhan Aly
Nourhan Aly
This study assessed the influence of CAD/CAM milling and 3D-printing fabrication methods on mechanical properties of 3-unit interim fixed dental prosthesis (IFDPs) after thermo-mechanical aging. Forty 3-unit IFDPs were fabricated on a mandibular right second premolar and second molar of a typodont cast. Samples were fabricated from the following materials; auto-polymerized polymethyl methacrylate (conventional resin), CAD/CAM PMMA (milled resin) and two different CAD/CAM 3D-printed composite resins; digital light processing Asiga (DLP AS) and stereolithography NextDent (SLA ND). Mechanical properties were compared between the studied materials using Kruskal–Wallis test, followed by multiple pairwise comparisons using Bonferroni adjusted significance. There was a significant difference in flexural strength and microhardness between the studied materials (p < 0.001), with the highest mean ± SD reported in the milled IFDPs (174.42 ± 3.39, 27.13 ± 0.52), and the lowest in the conventional IFDPs (98.02 ± 6.1, 15.77 ± 0.32). Flexural strengths differed significantly between the conventional IFDPs and all materials except DLP AS. The highest elastic modulus was recorded in the milled group, and the lowest in the SLA ND group (p = 0.02). In conclusion, superior flexural strength, elastic modulus, and hardness were reported for milled IFDPs. SLA ND printed IFDPs showed comparable mechanical properties to milled ones except for the elastic modulus.

4 June 2021 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
PEPassent Ellakany
Passent Ellakany
MTMaha El Tantawi
Maha El Tantawi
AMAmr A Mahrous
Amr A Mahrous
FAFahad Al‐Harbi
Fahad Al‐Harbi

19 August 2022 in Polymers
Verified
Journal Article
Open access
PDF file
FAFaris A. Alshahrani
Faris A. Alshahrani
FAFatemah AlToraibily
Fatemah AlToraibily
MAMaryam Ahmed Alzaid
Maryam Ahmed Alzaid
AMAmr A Mahrous
Amr A Mahrous
MAMaram A. AlGhamdi
Maram A. AlGhamdi
Mohammed GadMohammed Gad
Mohammed Gad
Salivary pH is a neglected factor that may affect the performance of removable dental prostheses (RDP). This study aimed to review literature in reference to the role of salivary pH on the performance of RDP and materials used for their fabrication. From January 1990 until December 2021, a search was done on PubMed, Scopus, and Web of Science databases using removable dental prostheses, salivary pH, PMMA, Denture base, and physical properties as keywords. Articles that met the inclusion criteria (full-length articles have investigated the effect of salivary pH on RDP materials in vitro and in vivo) were included. Out of 433 articles, 8 articles that met the inclusion criteria were included. All studies used artificial saliva with different salivary pH ranging between 3 and 14. Two articles investigated the role of salivary pH on the cytotoxicity of denture base resins and soft liner. One article studied the durability and retention of attachments, one article analyzed the performance of PEEK materials, one article researched the fatigue resistance of a denture base, one article investigated the corrosion of RPD framework cast and milled Co–Cr, one article studied the strength and clasp retention and deformation of acetal and PEEK materials, and one evaluated changes in mass and surface morphology of CAD–CAM fiber-reinforced composites for the prosthetic framework. Different salivary pH affected all included materials in this review except PEEK materials. The most adverse effect was reported with alkaline and acidic; however, the acidic showed the most deterioration effect. Salivary pH has a role in the selection of material used for RDP fabrication.

7 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
AMAmr A Mahrous
Amr A Mahrous
AAAbdullah Alhammad
Abdullah Alhammad
FAFaisal Alqahtani
Faisal Alqahtani
YAYousif Aljar
Yousif Aljar
AAAhmed Alkadi
Ahmed Alkadi
Mohammed GadMohammed Gad
Mohammed Gad
Pressable ceramic restorations have been introduced and investigated, and found comparable to CAD/CAM ceramic in terms of mechanical properties; however, the effect of toothbrushing on the pressable ceramic has not been thoroughly investigated. The objective of the current study was to assess the effect of artificial toothbrushing simulation on the surface roughness, microhardness, and color stability of different ceramic materials. Three lithium disilicate-based ceramics (IPS Emax CAD [EC], IPS Emax Press [EP]; (Ivoclar Vivadent AG), and LiSi Press [LP] (GC Corp, Tokyo, Japan)) were examined. For each ceramic material, eight bar-shaped specimens were prepared and subjected to 10,000 brushing cycles. Surface roughness, microhardness, and color stability (∆E) were measured before and after brushing. Scanning electron microscopy (SEM) was used for surface profile analysis. The results were analyzed using one-way ANOVA, Tukey’s post hoc test, and paired sample t-test α = 0.05. The findings revealed a non-significant decrease in the surface roughness of EC, EP, and LP groups (p > 0.05), and both LP and EP have the lowest surface roughness values (0.64 ± 0.13, 0.64 ± 0.08 µm) after brushing, respectively. Toothbrushing showed a decrease in the microhardness of the three groups: EC and LP, p < 0.001; EP, p = 0.012). EP showed the lowest hardness value after brushing (862.45 ± 273.83). No significant changes (∆E) were observed in all groups (p > 0.05); however, the EC group was found to be considerably affected by color changes, in comparison to the EC and LP groups. Toothbrushing had no effect on surface roughness and color stability of all tested materials, but it decreased the microhardness. Material type, surface treatments, and glazing of ceramic materials contributed to the surface changes in the ceramic materials, necessitating further investigations in terms of the toothbrushing effect with different glazing as variables.

15 August 2024 in Prosthesis
Verified
Journal Article
Open access
FAFaris A. Alshahrani
Faris A. Alshahrani
MAMaher AlGhamdi
Maher AlGhamdi
DADeena Alghamdi
Deena Alghamdi
HAHend Alshammary
Hend Alshammary
Sultan AkhtarSultan Akhtar
Sultan Akhtar
Mohammed GadMohammed Gad
Mohammed Gad
Purpose: This in vitro study aimed to evaluate and compare the physical and antimicrobial properties of provisional resin modified with two different nanoparticles, namely, silicon dioxide (nano-SiO2) and titanium dioxide (nano-TiO2). Methods: A commonly used commercially available polymethyl methacrylate (PMMA) provisional resin (Unifast III; GC Corp) was modified with nano-SiO2 and nano-TiO2 at different concentrations (1% wt. and 2.5% wt. respectively), while one unmodified group was used as a control. Rectangular specimens (60 × 10 × 3.3 mm) for strength (MPa) and elastic modulus, and square specimens (10 × 10 × 3.4 mm) for surface roughness (Ra, µm), hardness (VHN), and Candida albicans adhesion (colony forming unit, CFU/mL) were prepared and grouped into five groups (n = 10) according to (nanoparticles) NPs type and concentration. After polymerization, the specimens were finished and polished and then subjected to thermal cycling (5000 cycles). Analysis of variance and post-hoc Tukey test were used for data analysis (α = 0.05). The scanning electron microscope (SEM) was used for fracture surface analysis and C. albicans count. Results: The addition of 1% nano-SiO2 significantly increased the flexural strength, and 1% nano-SiO2 contributed to the highest flexural strength value, while 2.5% nano-SiO2 and nano-TiO2 showed non-significant increases (p > 0.05). The elastic modulus increased significantly for both NPs. Among the NP-modified groups, the nano-SiO2 groups showed an increased elastic modulus compared to the nano-TiO2 groups. The hardness significantly increased with NPs addition with no significant differences between NPs-modified groups. Surface roughness increased with 2.5% nano-TiO2 addition, while 1% nano-TiO2 and nano-SiO2 showed non-significant differences. Nano-SiO2 and nano-TiO2 significantly decreased C. albicans adhesion, and nano-TiO2 groups were significantly superior in their antimicrobial effect compared with nano-SiO2. Conclusions: Low nano-SiO2 addition increased the flexural strength of provisional resin. The addition of NPs increased elastic modulus and hardness and decreased the C. albicans adhesion to provisional resin. Nano-SiO2 did not alter the surface roughness, while 2.5% of nano-TiO2 increased the surface roughness.

5 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
SFShaimaa Mohamed Fouda
Shaimaa Mohamed Fouda
PEPassent Ellakany
Passent Ellakany
Mohammed GadMohammed Gad
Mohammed Gad
HBHala A. Bahgat
Hala A. Bahgat
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
AMAmr A Mahrous
Amr A Mahrous
Occlusal rest provides support for removable partial dentures (RPD). Rest seats are ideally prepared in enamel, but the abutment teeth might be restored or need restorations. This study compared the fracture strength of abutments restored with composite to amalgam restorations after rest seat preparation. Disto-occlusal cavities were prepared in 30 extracted human maxillary premolars. The specimens were allocated in three groups (n = 10) based on the type of restoration. All the specimens were exposed to thermomechanical aging followed by cycling loading. Fracture strength was tested using a universal testing machine, and then, the fracture mode was recorded. The data were analyzed using Kruskal–Wallis test with a significance level set at 0.05. The fracture mode was recorded as catastrophic or non-catastrophic. The fracture strength between all tested groups showed no significant difference. The highest and lowest fracture strength were recorded on amalgam and Tetric N-Ceram groups, respectively. Composite Tetric N-Ceram showed equal distribution of fracture sites on the restorative materials and teeth, it also displayed the highest number of non-catastrophic fractures unlike other groups where the fracture occurred more within the restorations. The fracture strength of composite was comparable to that of amalgam restorations with prepared rest seats.