Jesús Lázaro

Dr. Jesús Lázaro

Departamento de Tecnología Electrónica, Escuela de Ingenieria de Bilbao, Plaza Ingeniero Torres Quevedo, 148013 Bilbao, Spain
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
NMNaiara Moreira
Naiara Moreira
EMElías Molina
Elías Molina
JLJesús Lázaro
Jesús Lázaro
Eduardo JacobEduardo Jacob
Eduardo Jacob
AAArmando Astarloa
Armando Astarloa

1 June 2005 in Computer Vision and Image Understanding
Verified
Journal Article
Closed access
JMJose L. Martin
Jose L. Martin
AZAitzol Zuloaga
Aitzol Zuloaga
CCCarlos Cuadrado
Carlos Cuadrado
JLJesús Lázaro
Jesús Lázaro
UBUnai Bidarte
Unai Bidarte

29 March 2019 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
MUMarcelo Urbina
Marcelo Urbina
TATatiana Acosta
Tatiana Acosta
JLJesús Lázaro
Jesús Lázaro
AAArmando Astarloa
Armando Astarloa
UBUnai Bidarte
Unai Bidarte

4 October 2004 in Microprocessors and Microsystems
Verified
Journal Article
Closed access
JAJagoba Arias
Jagoba Arias
AZAitzol Zuloaga
Aitzol Zuloaga
JLJesús Lázaro
Jesús Lázaro
JAJon Andreu
Jon Andreu
AAArmando Astarloa
Armando Astarloa

1 January 1996 in IEE Proceedings - Generation, Transmission and Distribution
Verified
Journal Article
Closed access
IZI. Zamora
I. Zamora
JMJ.F. MiñaMbres
J.F. MiñaMbres
AMA.J. Mazón
A.J. Mazón
RAR. Alvarez-Isasi
R. Alvarez-Isasi
JLJesús Lázaro
Jesús Lázaro
A new method for locating faults in two-terminal transmission lines is discussed. The procedure is based on the fundamental components of fault and prefault voltage at 50/60 Hz measured at the two ends of a transmission line. The methodology allows one to establish a direct calculation procedure that is independent of fault and prefault currents, fault type, fault resistance, synchronisation condition of register devices located on line ends, and prefault condition, either balanced or not. This is achieved by defining a new concept called ‘distance factor’. The technique developed was validated at two levels: first, from exact data obtained using a fault simulation software program, which allows the accuracy to be evaluated, and secondly, from erroneous voltage data taken at the ends of the line or from erroneous source impedances, which allows assessment of the sensitivity against incorrect data.

26 March 2021 in IEEE Access
Verified
Journal Article
Open access
MRMikel Rodriguez
Mikel Rodriguez
JLJesús Lázaro
Jesús Lázaro
UBUnai Bidarte
Unai Bidarte
JJJaime Jiménez
Jaime Jiménez
AAArmando Astarloa
Armando Astarloa
International Electrotechnical Commission (IEC) 62351-6 standard specifies the security mechanisms to protect real-time communications based on IEC 61850. Generic Object Oriented Substation Events (GOOSE) and Sampled Value (SV) messages must be generated, transmitted and processed in less than 3 ms, which challenges the introduction of IEC 62351-6. After evaluating the security threats to IEC 61850 communications and the state of the art in GOOSE and SV security, this work presents a novel architecture based on wire-speed processing able to provide message authentication and confidentiality. This architecture has been implemented and tested to evaluate its performance, resource usage, and the latency introduced. Other proposals in the scientific literature do not support real-time traffic, so they are not suitable for GOOSE and SV messages. Whereas the others exceed the target latency of 3 ms or do not comply with the standards, our design authenticates and encrypts real-time IEC 61850 data in less than 7 μs-predictable latency-, and complies with IEC 62351:2020.